Urgency: Immediate Within6months
Update material required? Yes No
Materials free of charge? Yes No
Return of parts? Yes (See page 3) No
Estimated completion time: 1 h Number of CSE’s: one (1)
Customer application training? Yes No
Systems/Products affected/System identifying IVK
NameMaterial No.Serial No.
Exchange of Diaphragm
X
X
X
SP017/02/P
X
X
X
Mammomat 100061 34 7098601 - 9131
Remark: Affected units delivered to different countries within the serial number interval, see table on page 2.
Print No.: SPB7-230.896.11.01.02Doc. Gen. Date:10.02
Replaces: n.a.66 31 803Page 1 of 6
The reproduction, transmission or use
of this document or its contents is not
permitted without express written
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model _or_ design,_are_
reserved.
Page 2
2Update Instructions SP017/02/P
Document Revision Level0
This document corresponds to the version/revision level effective at the time of system
delivery. Revisions to hardcopy documentation are not automatically distributed.
Please contact your local Siemens office to order current revision levels.
Disclaimer0
The installation and service of equipment described herein is to be performed by qualified
personnel who are employed by Siemens or one of its affiliates or who are otherwise
authorized by Siemens or one of its affiliates to provide such service.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service procedures.
Systems/Products Affected0
Mammomat 1000 (mat. no. 61 34 709) within serial number interval 8601 - 9131. See
table below for detailed designation of affected units.
CountryNumber of
Update Kits
Austria19054
France18636
Germany68680
India18611
Italy18725
Japan29033
Pakistan19108
Philippines19038
Portugal19053
South Korea19037
Spain38601
The Netherlands18699
Turkey48640
Uruguay19008
Tab. 1Designation of affected units
Serial No.
Mammomat 1000
9014
9059
9060
9083
9105
9051
8639
8641
9056
9057
9131
Mammomat 1000SPB7-230.896.11Page 2 of 6Siemens AG
Rev. 0110.02CS PS 24/SPSMedical Solutions
Page 3
Update Instructions SP017/02/P3
Reason for the Update0
A number of faulty diaphragms have been delivered together with the Mammomat 1000 in
the mentioned serial number interval.
These diaphragms can be mounted in the wrong position giving a white stripe along the
chest wall.
These faulty diaphragms must be exchanged to the ones delivered in the Update Kit.
18 x 24 CM
SID 65 CM
MODEL No.:
SERIAL/LOT No.:
This product complies with DHHS regulations
21 CFR Subchapter J, applicable at date of
manufacture:
Manufactured:
Siemens Aktiengesellschaft
Wittelsbacherplatz 2. D-8 Munchen 2
Germany
R 8 mm x 2
R 4 mm x 2
18 x 24 CM
SID 65 CM
MODEL No.:
SERIAL/LOT No.:
This product complies with DHHS regulations
21 CFR Subchapter J, applicable at date of
manufacture:
Manufactured:
Siemens Aktiengesellschaft
Wittelsbacherplatz 2. D-8 Munchen 2
Germany
R 8 mm x 4
MAM00950
Fig. 1 Difference between right and faulty diaphragm
Prerequisites0
No special prerequisites.
Special Tools / Documents0
No special tools needed.
Ordering Information0
The following update kit has to be ordered from CSML (SAP Distribution Chan nel, factory
2050):
Update Kit Diaphragm M1000 66 33 148 X041E
Siemens AGSPB7-230.896.11Page 3 of 6Mammomat 1000
Medical SolutionsRev. 0110.02CS PS 24/SPS
Page 4
4Update Instructions SP017/02/P
Contents of the Update Kit0
The Update Kit 66 33 148 contains the following parts:
Pos.Quan.Material No.Name
1164 83 692Diaphragm, 18x24, deep
2164 83 700Diaphragm, Magnification, deep
3166 31 803Update Instructions, UI SP017/02/P
Tab. 2Contents of the Update Kit
Return of Parts0
There is no requirement on return of faulty diaphragms back to CSML for scrapping. The
diaphragms can be scrapped by the CSE at the Regional Unit.
Work Steps0
• Exchange the faulty diaphragms at site with the ones delivered with the Update kit.
• Scrap the faulty diaphragms.
Customer Information0
n.a.
Final Work Steps0
• Update the system documentation.
Update the revision level, the operating instructions and the technical documentation.
Fill out, and if needed, make a copy of the attached "Completion Protocol/ Update
Completion Form" and file it in the corresponding System Binder/User Handbook.
• This update includes an IVK.
- Changes in the IVK structure must be reported to the management system to correct
the installed volume.
• Updates that have already been completed prior to publication of this UI must also be
reported.
• The update is reported as follows:
- The modification reply cards (Type 606) previously distributed with the publication of
updates no longer apply.
- The modification reply report has to be prepared by authorized personnel using an
application on the Intranet.
Mammomat 1000SPB7-230.896.11Page 4 of 6Siemens AG
Rev. 0110.02CS PS 24/SPSMedical Solutions
Page 5
Update Instructions SP017/02/P5
Completion Protocol/Update Completion Form0
The update with the number SP017/02/P has been completed.