Siemens AC265, A265, C365 HF, C360 HF, A260 Service Manual

...
Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential 1 SHC CC RCT Version 1.5 J. Junggebauer
Gigaset A160 (CL6010, C360, AC160),
A165 (CL6015, C365, AC165), A260
(C360 HF), A265 (C365 HF, AC265)
Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential 2 SHC CC RCT Version 1.5 J. Junggebauer
Table of Content
1. INTRODUCTION............................................................................................................................................. 3
1.1 P
URPOSE
................................................................................................................................................. 3
1.2 S
COPE
..................................................................................................................................................... 3
1.3 T
ERMS AND ABBREVIATIONS
................................................................................................................. 3
1.3.1 Terms................................................................................................................................................. 3
1.3.2 Abbreviations .................................................................................................................................... 3
2 REQUIREMENTS....................................................................................................................................... 4
2.1 S
OFTWARE REQUIREMENTS
.................................................................................................................... 4
2.2 H
ARDWARE REQUIREMENTS
................................................................................................................... 4
2.3 S
PECIAL EQUIPMENT AND TOOLS
............................................................................................................ 4
3 PROCEDURES ............................................................................................................................................ 5
3.1 F
UNDAMENTAL RESET
........................................................................................................................... 5
3.2 S
ERVICE PROCEDURES FOR
A16
AND
A26
HANDSET
.............................................................................. 5
3.3 S
ERVICE PROCEDURES FOR
A160/65
AND
A260/65
BASE
....................................................................... 6
4 TEST SETUP RECOMMENDATION......................................................................................................8
4.1 T
EST STEPS HANDSET
........................................................................................................................... 10
4.2 T
EST STEPS BASE STATION
.................................................................................................................... 10
5 REPAIR ...................................................................................................................................................... 11
5.1 D
ISASSEMBLING HANDSET
................................................................................................................... 11
5.2 R
EPAIR OF RECEIVER
............................................................................................................................ 12
5.3 D
ISASSEMBLING BASE STATION
A160, A260 ....................................................................................... 13
5.4 R
EPAIR OF
C104................................................................................................................................... 15
5.5 R
EPAIR OF
N602................................................................................................................................... 16
Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential 3 SHC CC RCT Version 1.5 J. Junggebauer
1. Introduction
This document describes the service procedures and test instructions of an A160/65 and A260/65 system. The construction of the A160 is identical with CL6010 and C360. The PCB is different. The PCBs of the AC 160/165/265 system are identical with the A160/165/265 system. The construction of the A165 is identical with CL6015 and C365. The PCB is different. The construction of the A260 is identical with C360 HF. The PCB is different. The construction of the A265 is identical with C365 HF. The PCB is different.
1.1 Purpose
This document enables a workshop to check the above mentioned systems. The test is necessary to decide whether this unit is faulty.
1.2 Scope
Scopes of the document are service procedures and test steps.
1.3 Terms and Abbreviations
1.3.1 Terms
1.3.2 Abbreviations
Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential 4 SHC CC RCT Version 1.5 J. Junggebauer
2 Requirements
2.1 Software requirements
none
2.2 Hardware requirements
Gigaset 4170 or 4175 to be used as a PBX
Gigaset handset which is registered on Gigaset 4175
Gigaset A160, A260, A165 or A265 base station to test customer‘s handset
Gigaset A16 and A26 handset to test customer‘s base station
1 AC adaptor where the cable is opened (cut off) for the amperemeter
1 Mini-Western PSTN cable with a parallel cable for the voltmeter
1 voltmeter to measure the PSTN line voltage of the customer‘s base
1 amperemeter to measure the AC-current of the AC-adaptor connected
to the customers base station
2.3 Special equipment and tools
none
Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential 5 SHC CC RCT Version 1.5 J. Junggebauer
3 Procedures
3.1 Fundamental Reset
Disconnect mains. Press paging key on base station and hold down. Plug in AC- adapter. Hold key pressed for more than 3 seconds. Release paging key. The base station is now set to factory defaults. The system-PIN is reset to 0000 and all mobile units are deregistered.
3.2 Service procedures for A16 and A26 handset
Read out IPUI of the handset (for identification purposes): menu-key, *, #, 0, 6, #
SW-version: Read out SW-version and IPUI (international portable user identity) of handset.
IPUI is a unique number (like IMEI) that could be used for identification.
Speechpath-test: Switches a direct loop between microphone and loudspeaker. This
enables a check of the speechpath by blowing in the microphone.
Metering mode: Press o.k. to activate an information line during normal operation mode and
leave the service menu afterwards. Example: 100 - 0 - 02 - 016 - 100
RX-level - Frequency - Time slot - Base code - Bit error rate (100 = 100% o.k.)
Measure time: Changes the measure time of the metering mode (change is not necessary).
Working time: Read out the time for which the handset has been switched on. Example:
100h means handset has been switched on for 100 hours. The counter can only be reset at WSC.
Press 1, 4 and 7 simultaneously and keep keys pressed
Switch on and keep key pressed until "SERVICE" is visible, then release all keys
Press 4685463 (HOTLINE)
This code performs a fundamental reset on the handset. All settings are reset to factory defaults. Handset is still registered to base.
Service-menu is displayed with following items:
SW-version, QS-data, Speechpath test, Battery
mode, DSP-parameters, Metering mode,
Measure time, Working time, SAR.
Red items are only for Development Department or Quality Assurance and not explained here!