Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
English
SWING 2 MG
23021093MG
ELECTRONIC CONTROL UNIT FOR SWING GATES
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. +39 0861 588341 r.a. Fax +39 0861 588344
www.seateam.com
seacom@seateam.com
67410673 |
REV 00 - 12/2013 |
®
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SWING 2 MG
INDEX |
|
COMPONENTS DECRIPTION ..................................................................................................... |
3 |
CONNECTIONS............................................................................................................................ |
4 |
GENERAL INFORMATION .......................................................................................................... |
5 |
FUNCTION LOGICS SETTING (DIP-SWITCH)............................................................................ |
6 |
ADDITIONAL FUNCTIONS (DIP-SWITCH) .................................................................................. |
7 |
TRIMMER ADJUSTMENT ............................................................................................................ |
8 |
ALARMS INDICATIONS TABLE.................................................................................................... |
8 |
PALM FUNCTIONS....................................................................................................................... |
8 |
START, STOP, PEDESTRIAN START, ANTENNA, PHOTOCELLS, ELECTRIC LOCK, WARNING |
|
LAMP, EDGE CONNECTIONS .................................................................................................... |
9 |
POWER SUPPLY AND MOTOR CONNECTIONS...................................................................... |
10 |
WORKING TIMES SELFLEARNING ON SWING GATE............................................................. |
11 |
SINGLE LEAF MODE ................................................................................................................. |
13 |
RADIO TRANSMITTERS MEMORIZING.................................................................................... |
14 |
RADIO TRANSMITTERS CANCELLATION................................................................................ |
14 |
SAFETY LOOP CONNECTION .................................................................................................. |
15 |
TROUBLE SHOOTING ............................................................................................................... |
16 |
WARNINGS AND GUARANTEE................................................................................................. |
16 |
2 |
67410673 |
REV 00 - 12/2013 |
®
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SWING 2 MG
COMPONENTS DESCRIPTION
|
|
RL1 |
TR1 |
|
|
|
F1 |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
TR2 |
|
|
TRASF |
|
RL2 |
|
|
|
CN2 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
TR3 |
|
|
|
|
|
|
|
|
|
L9 |
|
|
|
|
F2 |
|
TR4 |
|
MEM |
µP |
|
|
|
|
L8 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
L7 |
|
|
|
|
1 |
|
|
L6 |
|
Rv3 |
Rv2 |
Rv1 |
|
|
|
|
|
2 |
|
|
L5 |
CN1 |
|||
3 |
|
|
|||||
CNP |
|
|
4 |
DIP |
|
L4 |
|
|
|
|
5 |
|
|
||
|
|
|
6 |
|
|
|
|
|
|
|
7 |
|
|
L3 |
|
|
|
|
8 |
|
|
|
|
Rv4 |
LEDP |
9 |
|
|
|
|
|
10 |
CMR |
L2 |
|
||||
|
|
|
|
||||
|
|
|
L1 |
|
|||
|
|
|
|
|
|
|
|
|
Ptime |
PCode |
|
|
|
|
|
CN1 = 24 V input/output connector |
Rv1 = Motor torque adjustment |
||
CN2 = Motors and power supply connector |
Rv2 = Pause time adjustment |
||
CMR = Radio Receiver connector |
Rv3 = Courtesy light or flashing lamp delay adjustment |
||
CNP= Connector PALM |
Rv4 = Slowdown times adjustment |
||
L1 |
= Start |
PTime = Working times learning push-button |
|
L2 |
= Pedestrian Start |
Pcode = Radio transmitters learning push-button |
|
L3 |
= Stop |
DIP = Function Dip-switch setting |
|
L4 |
= Photocell 1 |
RL1 = Motor power supply relay |
|
L5 |
= Photocell 2 |
RL2 = Motor direction relay |
|
L6 |
= Safety edge |
µP = Microprocessor |
|
L7 |
= 24V Aux |
MEM = Memory |
|
L8 |
= 24V Flash |
TRASF = Transformer |
|
L9 |
= Electro-lock |
TR1 = Triac courtesy light |
|
LEDP = Programming |
TR2 = Triac motor 1piloting |
||
F1 |
= Power supply and motor 6.3AT fuse |
TR3 = Triac motor 2 piloting |
|
TR4 = Tip 127 electro-lock piloting |
|||
F2 |
= Accessories Fuse 1A |
||
|
67410673 |
REV 00 - 12/2013 |
3 |
®
SWING 2 MG
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
CONNESSIONI / CONNECTIONS / CONNEXIONS
CONEXIONES / VERBINDUNGEN
CN1
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 12 |
13 |
14 |
Antenna / Antenna Antenne / Antena Antenne |
Comune / Common Comun / Común Gemeinsam |
Start |
STARTPed./ START Ped. STARTPiéton / START Peat. START Fuss. |
Stop |
Comune / Common Comun / Común Gemeinsam |
Fotocellula1/ Photocell 1 Photocellule1 / Fotocélula 1 Lichtschranke 1 |
Fotocellula2/ Photocell 2 Photocellule2 / Fotocélula 2 Lichtschranke 2 |
Costa/ Edge / Tranche / Banda de seguridad / Sicherheitsleiste |
24V Aux (300 mA max) |
Comune / Common Comun / Común Gemeinsam |
24V (300 mA max) |
24V(Lamp.) / 24V (Flash) |
(Lampe)24V / 24V (Lámpara) |
24V (Blinklampe) |
(300 mA max) |
Lock |
|
RADIO MODULE (CNA) |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CN2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
|
|||||||
M2 Aperto M2 Open |
M2 Chiuso M2 Close |
M2 Neutro M2 Neutral |
M1 Aperto M1 Open |
M1 Chiuso M1 Close |
M1 Neutro |
Condensatore Capacitor |
Condensatore Capacitor |
M2 |
M1 |
|
DIP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
|
2 |
3 |
4 |
5 |
6 |
|||||||||||||||
|
Selezione logiche Mode1 |
|
|
Mode2 |
|
Pre lampeggio Pre-blink |
|
Autotest fotocell. Photo test |
|
Rallentamento Soft stop |
|
Serraggio anta Push Over |
|
|||||||||
|
Logic selection |
|
|
|
|
|
|
|
||||||||||||||
4 |
67410673 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 7
M1 Neutral |
Luce di cotesia (Linea) |
Courtesy light (Line) |
Luce di cortesia (Neutro) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
8 |
|
||
Colpo d’inversione Reverse stroke |
|
Singola anta One motor |
|
Richiusura con fotocell. |
|
|
|
|
|
8
Courtesy light (Neutral)
9
with photocell |
Costa / Timer |
Reclosing |
|
|
|
|
|
|
|
|
|
Connettore modulo ricevente |
|
|
|
|
|
|
|
|
|
|
|
|
|
Receiver module connector |
|
|
|
|
|
|
Connecteur module récepteur |
9 |
10 |
Conector modulo receptor |
||||
Verbindungsmodul Empfänger |
||||||
Neutro Neutral |
Linea Line |
CNP |
Connettore Programmatore PALM COPY
Connector programmer PALM COPY
Connecteur programmer PALM COPY
Conector Programador PALM COPY
Anschluss Programmierer PALM COPY
REGOLAZIONE TRIMMER
TRIMMER ADJUSTMENT
Rv4 |
Rv3 |
|
Tempo di |
|
Tempo luce |
rallentamento |
|
di cortesia |
Slow down time |
|
Light time |
10 |
Rv2 |
Tempo di pausa e |
|
|
|
Edge/Timer |
|
richiusura |
|
automatica |
|
|
Pause - |
|
Rv1 |
autotest close |
|
|
|
|
|
|
Coppia motore |
|
|
Power |
REV 00 - 12/2013 |
|
|
®
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SWING 2 MG
GENERAL INFORMATION
GENERAL FEATURES
SWING 2 MG control unit has been deigned in order to manage one or two swing operators without limit switch. Its dimensions are very small, four different operation modes, possibility to adjust many parameters using the trimmer and dip switch.
TECHNICAL FEATURES
Control unit power supply |
230V ~ (±10%) - 50/60 Hz / 115V~ (±10%) 50/60 Hz |
|||
Transformer 230V / 115V |
P1: Vn=230V~, Io=43.3 mA; S1: Vnom=17.5V~, Vo=20.2V~, I=0.69A |
|||
|
P1: Vn=115V~, Io=43.3 mA; S1: Vnom=17.5V~, Vo=20.2V~, I=0.69A |
|||
Absorbed power |
7,5 W |
|
|
|
Max. motor charge |
500 W x 2 |
|||
Max. accessories charge |
24V |
|
300mA |
|
Max. charge flashing lamp or |
230V~ 50W max. |
|||
Courtesy light |
|
|
|
|
Max. flashing light charge 24V |
24V |
|
4V Led |
|
Environment temperature |
-20°C |
|
+50°C |
|
|
|
|||
|
|
|
|
|
Protection fuses (24V accessories) |
1 A |
|
|
|
Programming modes |
Selflearning page 12 |
|||
Operating logics |
Automatic / Safety / St.by St.1 / St. by St. 2 / Dead man / |
|||
|
2 Butons |
|||
Opening / closing time |
Adjsutable in autoprogramming |
|||
Pause time |
Adjustable with trimmer from 0 to 120 s |
|||
Courtesy light delay |
Adjustable with trimmer from 0 to 2 min. |
|||
Thrust force |
Adjustable with trimmer |
|||
Slowdowns |
Adjustable with trimmer |
|||
Leaf delay |
In selflearning |
|||
|
|
|
|
|
Connecting terminal entries |
Antenna / Stop / Start / Pedestrian Start / |
|||
|
Photocells 1 and 2 / Edge |
|||
Connecting terminal exits |
Power supply accessories 24V / Motors 230V 500W x 2 / |
|||
|
Flashing lamp or courtesy light 230V 50W / Electro-lock12V |
|||
|
15VA max/ TX photocell power supply 24V / Capacitors |
|||
Board dimensions |
150,7 x 141 x 47,5 mm |
|||
Outside box features |
305 x 225 x 125 mm - IP55 |
67410673 |
REV 00 - 12/2013 |
5 |
®
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SWING 2 MG
OPERATING LOGICS (DIP-SWITCH)
DIP
ON
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 10 |
DIP |
WORKING LOGICS
Four different working logics can be selected.
The programming takes place using DIP1 and DIP2.
- MANUAL LOGIC
A START command opens the gate. A second START while it is opening stops the motor. A START command while it is closing stops the motor.
Important note: To obtain the semi-automatic reclosing turn the trimmer Rv2 completely clockwise.
- SAFETY LOGIC
A START command opens the gate. A second START while it is opening reverses the motor, a start closes the gate.
A START command while it is closing reverses the motor.
Important note: To obtain the semi-automatic reclosing turn the trimmer Rv2 completely clockwise.
- AUTOMATIC LOGIC 1 (with automatic closing)
A START command opens the gate. A second START while it is opening is not accepted. A START while in pause is not accepted, at the end of the pause the automation closes, a START while it’s closing reverses the motor.
Important note: To obtain the semi-automatic reclosing turn the trimmer Rv2 completely clockwise.
- AUTOMATIC LOGIC 2
A START command opens the gate. A second START while it is opening is not accepted. A START during the pause time closes the gate immediately. A START while it is closing reverses the direction.
Important note: To obtain the semi-automatic reclosing turn the trimmer Rv2 completely clockwise.
DIP |
OPENED |
DIP1 AND DIP2 PROGRAMMING FOR THE SELECTION OF THE WORKING LOGIC |
CLOSED |
||
1 / 2 |
OFF / OFF |
If Dip1 and Dip2 are programmed in this way, the control unit will work with Manual Logic |
|
|
|
1 / 2 |
ON / OFF |
If Dip1 and Dip2 are programmed in this way, the control unit will work with Safety Logic |
|
|
|
1 / 2 |
OFF / ON |
If Dip1 and Dip2 are programmed in this way, the control unit will work with Automatic 1 Logic |
|
|
|
1 / 2 |
ON / ON |
If Dip1 and Dip2 are programmed in this way, the control unit will work with Automatic 2 Logic |
|
|
|
6 |
67410673 |
REV 00 - 12/2013 |