Sistemi Elettronici |
|
|
|
|
di Apertura Porte e Cancelli |
Italiano |
|
||
International registered trademark n. 804888 |
|
|||
|
|
|
||
|
|
|
|
|
|
|
English |
|
|
|
|
|
|
|
GATE 1 DG R1 |
|
Français |
|
|
|
|
|
||
|
Español |
|
||
|
|
|
|
CENTRALE DI COMANDO PER CANCELLI SCORREVOLI, BATTENTI, BARRIERE E PORTE DA GARAGE CONTROL UNIT FOR SLIDING GATES, SWING GATES, BARRIERS AND GARAGE DOORS
ARMOIRE DE COMMANDE POUR PORTAILS COULISSANTS, BATTANTS, BARRIERES ET PORTES DE GARAGE CENTRAL ELECTRÓNICA PARA CANCELAS CORREDIZAS, ABATIBLES, BARRERAS Y PUERTAS BASCULANTES
(Cod. 23001158)
tras
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. +39 0861 588341 r.a. Fax +39 0861 588344
www.seateam.com
seacom@seateam.com
67410182 |
Rev.06 - 09/2014 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
COMPONENTS
TECHNICAL SPECIFICATIONS
Control unit power supply: 230 Vac 50/60 Hz - 115Vac 50/60 Hz
Absorption in stand by: 30 mA
Environment temperature : -20°C +50°C
Specifications of external enclosure: 183 X 238 X 120 - Ip55
|
|
|
|
CN3 |
|
CN2 |
|
|
F1 |
|
|
|
|
|
|
|
|
|
|
T1 |
|
|
|
|
TR1 |
R1 |
|
|
|
|
|
|
|
R2 |
|
155 mm |
CMS |
CN5 |
|
|
|
RECEIVER RX |
CN4 |
EXP |
F2 |
|
||
|
|
|
|
|
|
CNP |
|
|
CNS |
|
|
|
JOLLY |
|
|
|
|
|
|
|
|
|
|
|
|
DS |
|
|
|
|
CNA |
|
|
|
|
|
|
|
|
|
JOLLY-JOLLY2 |
|
|
|
|
|
|
CN6 |
|
|
CNS |
|
UP |
DOWN |
OK |
|
|
|
|
|
|
CN7 |
|
|
|
|
|
CN1 |
|
CN1 = Input/output connectors
CN2 = Motor and capacitors and courtesy light connector
CN3 = Power connector
CN4 = 24V~ connector
CN5 = Encoder connector
CN6 = Pre-wired limit switch connector
CN7= Limit switch connector not pre-wired
CNA = RX Receiver connector
CNP = Porgramming connector
CNS = RF FIX Receiver connector
EXP = Expansion module connector
85 mm
JOLLY = Jolly and Jolly 2 connector
DS = Programming display
CMS = MASTER/SLAVE connector
OK = Programming button
DOWN = Programming button
UP = Programming button
T1 = Motor piloting Triac
R1 = Relay C motor command courtesy light
R2 = Relay motor exchange
F1 = 6.3AT fuse on 230V/10AT on 115V
F2 = Accessories 1A fuse
TR1 = Power transformer
22 |
67410182 |
Rev.06 - 09/2014 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
CONNECTIONS
RADIO MODULE RF FIX (CNS)
RF FIX
Receiver connector
(Available from hardware revision R2)
|
|
|
|
|
|
|
|
|
CN2 |
|
|
|
|
|
|
|
|
|
|
CN4 |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14 15 |
16 17 |
|
18 |
19 20 |
|
|
|
|
|
|||||||||||||||||||
|
|
24Vac |
|
|
|||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
LIGHT LIGHTN MCL |
|
MN |
|
MOP |
|
CAPACITOR |
|
|
|
|
||||||||||||||||||
|
|
LightFlash |
|
NFlash |
closing1Motor |
|
|
Neutral1Motor |
|
|
opening1Motor |
|
Capacitor 1Motor |
Max 150 mA |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
M1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24V (Red)
Limit switch Closing 1 (Yellow) Limit switch Opening 1 (Green)
Common (White)
Limit switch Closing 1 (Yellow) Limit switch Opening 1 (Green)
CN6 |
|
|
LIMIT |
1 |
SWITCH |
CN7 |
CN1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
|
2 |
3 |
4 |
5 |
6 |
|
7 |
|
8 |
9 |
10 |
11 12 13 |
|||||||||||||
|
ANT |
COM START PEDST STOP COM |
PH1 |
PH2 EDGE 24VAUX COM 24V(FL) (FL)- |
+ |
- |
+ |
- |
Antenna |
Common |
Start |
START Pedestrian |
Stop |
Common |
Photocell 1 |
Photocell 2 |
Safety edge 1 |
AUX (24V 500 mA max) |
Common |
24V 500 mA max (Accessories) |
Flash (-) |
JUMPERS
WARNING: The control unit is designed with the automatic detection of not used N.C. inputs (Photocells, Stop and Limit switch) except the SAFETY EDGE input. The exclude inputs in self-programming can be restored in the “Check inputs” menu without need to repeat the programming (page 33).
CN1
Obligatory jumper without accessory connection.
Optional
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
|
2 |
3 |
4 |
|
5 |
6 |
|
7 |
|
8 |
9 |
10 |
11 12 13 |
||||||||||||
|
ANT |
COM START PEDST STOP COM |
PH1 |
PH2 EDGE 24VAUX COM 24V(FL) (FL)- |
+ |
- |
+ |
- |
Antenna |
Common |
Start |
START Pedestrian |
Stop |
Common |
Photocell 1 |
Photocell 2 |
Safety edge 1 |
AUX (24V 500 mA max) |
Common |
24V 500 mA max (Accessories) |
Flash (-) |
The herein reported f u n c t i o n s a r e available starting from revision 12.
67410182 |
Rev.06 - 09/2014 |
23 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
PROGRAMMING
QUICK START
UP
SEA
MENU SET
1 LANGUAGE
UP
SEA
MENU SET
2 TRANSMITTERS
UP
SEA
MENU SET
3 MOTOR
|
|
UP |
|
|
|
4 |
MENU |
SEA |
SET |
||
|
|
(See LOGIC page 25)
UP
SEA
MENU SET
5 PAUSE TIME
|
UP |
|
|
|
|
|
|
|
SEA |
SET |
|
|
MENU |
||
6 |
START IN |
||
|
PAUSE |
|
|
|
UP |
|
|
|
|
|
|
7 |
SEA |
SET |
|
MENU |
|||
PROGRAM- |
|||
(See |
|||
MING |
|
||
page 25) |
|
UP
SEA
MENU SET
8 TEST START
|
SEA |
SET |
|
|
|
|
|
|
|
|
|
|
|
|
|
PROGRAMMING |
||
|
MENU |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
OK |
ITALIANO |
|
|
|
|
|
|
|
|
|
|
|
|
|
BUTTONS |
|||
|
|
|
|
|
|
UP DOWN |
OK |
|||||||||||
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
||||||||||||
|
Skip this step if you do not want to program a transmitter |
|
OK to exit |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Press the |
|
|
|
|
Menu |
|||
|
SEA |
SET |
|
|
|
SEA |
SET |
|
|
MENU |
SEA |
|||||||
OK |
MENU |
|
OK |
|
MENU |
|
button of the |
|
SET |
or press the |
||||||||
|
|
|
|
PRESS |
|
|
|
|
|
|||||||||
START |
|
|
TX to be |
|
|
STORED |
button of |
|||||||||||
|
|
|
|
BUTTON |
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
stored |
|
|
|
|
the next |
||||
|
|
|
|
|
Check if a receiver has |
|
|
|
|
|
|
|
|
TX to be stored |
||||
If on the display |
MENU |
SEA |
SET |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|||||||||
RECEIVER |
|
been connceted |
|
|
|
|
|
|
|
|
|
|
|
|||||
appears the item: |
|
|
|
|
|
|
|
|
|
|
|
|
||||||
MISSING |
|
(see page 22) |
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OK |
Choose the type of |
OK |
To confirm and return |
|
motor with |
||||
|
|
to main menu |
||
|
UP or DOWN |
|
||
|
|
|
With UP or DOWN OK choose
the desired logic
With UP or DOWN OK choose a delay for automatic closing
OK With UP or DOWN Choose ON
OK |
To confirm and return |
|
to main menu |
OK |
To confirm and return |
|
to main menu |
OK To confirm and return to main menu
Skip this step
if you wna tto work
in half-automatic
logic
OK |
With UP or DOWN choose ON |
OK |
At the end of the selflearning |
the control unit returns automatically |
|||
|
to start times learning |
|
to the main menu |
|
|
|
|
|
The gate will execute a CLOSING-OPENING-CLOSING CYCLE |
||
|
Skip this step if a TX has already been stored |
||
OK |
With |
OK |
To confirm and return to |
UP or DOWN Choose |
|||
|
ON to start test |
|
main menu |
ALL OTHER PARAMETERS HAVE DEFAULT SETTINGS WHICH ARE USEFUL FOR THE 90% OF THE APPLICATIONS BUT CAN BE HOWEVER SET THROUGH THE SPECIAL MENU. FOR
ENTERING INTO THE SPECIAL MENU MOVE ON ONE OF THE MENU AND PRESS THE UP
DOWN UP
AND DOWN BUTTONS AT THE SAME TIME FOR 5 S.
24 |
67410182 |
Rev.06 - 09/2014 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
MENU FUNCTIONS TABLE GATE 1 DG R1
MENU
1 - langvage
2 - trans |
U |
tters |
|
3 - |
U |
otor |
|
4 - log (
(See page 27)
5 - paVse t |
U |
e |
|
6 - start n pavse
UU |
ng |
7 - progra |
|
(See page 26) |
|
8 - test start
end
SET
tal ano
engl sk
fran(a s
espanol
dut(k
start
Pedestr an Start
External |
U |
odvle |
|
||
stop |
|
|
vnlo(k |
|
|
|
|
U |
Delete a trans itter
Description |
Default |
Set value |
Italian |
|
|
English |
|
|
French |
tal ano |
|
Spanish |
|
|
Dutch |
|
|
Start |
|
|
Pedestrian Start |
|
|
External module |
|
|
Stop |
start |
|
Storing of a command |
Ped Start. |
|
for unlocking an |
|
|
|
|
|
electric brake |
|
|
Delete single transmitter |
|
|
(Lear |
UU |
Delete transmitter memory |
|
|
|
|
|
e ory |
|
|
|
|
|
||
Ele(trokydravl ( |
Electrohydraulic |
|
|
|
|
|
|
Sl d ng |
Sliding |
|
|
|
|
|
|
|
|
|
|
|
|
||
REUERS BLE Sl d ng gate Reversible sliding gate |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
U |
|
Sliding gate with magnetic |
|
|
|
|
|
|
|
|
|
|
|
|
|
AGNET ( Sl d ng gate |
limit switch |
|
U |
E(kan ( |
|
||
|
|
|
|
|
|||
Tripkase - bvll |
Three-phase - Bull |
|
|
|
|
|
|
seagear |
Seagear |
|
|
|
|
|
|
UE(kan ( |
Hydraulic motors |
|
|
|
|
|
|
Sprint fast |
Sprint Fast |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
U |
|
Automatic |
|
|
|
|
|
Avto at ( |
|
|
|
|
|
||
open-stop-(lose-stop-open Step by step type 1 |
|
|
|
|
|
||
open-stop-(lose-open |
Step by step type 2 |
|
|
|
|
|
|
|
|
|
|
|
U |
|
|
|
|
|
|
|
|
||
2 bvttons |
Two buttons |
|
Avto at ( |
|
|||
|
|
|
|
|
|||
safety |
Safety |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DeadUan |
Dead man |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
off |
|
OFF |
|
|
|
|
|
|
(semi-automatic logics) |
|
|
off |
|
||
|
|
|
|
|
|||
1 240 |
|
Setting from 1s to 4min. |
|
|
|
|
|
off |
|
In pause start is not acceped |
|
|
off |
|
|
|
|
|
|
|
|
||
on |
|
In pause start is accepted |
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Off on |
Times learning start |
|
|
off |
|
|
|
Off on |
Start command |
|
|
off |
|
|
|
|
Select END and press OK to exit the menu.The menu |
|
|||||
|
deactivates automatically after 2 minutes |
|
|||||
|
|
|
|
|
|
|
|
67410182 |
Rev.06 - 09/2014 |
25 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
WORKING TIMES SELF LEARNING
The control unit is pre-set with the default settings, to start the control unit with the DEFAULT settings just keep pressed the UP and DOWN buttons at the same time power supplying the control unit the display shows the message init.
The DEFAULT settings are shown in the Menues table.
LEARNING WITH LIMIT SWITCH (WITH OR WITHOUT ENCODER)
When limit switches are mounted, the gate executes automatically the following cycle: CLOSING - OPENING - CLOSING.
Before starting the learning, make sure (through the test menu), that the relative limit switches of every opening are employed.
WORKING TIMES SELFLEARNING THROUGH IMPULSES
ATTENTION: This procedure is potentially dangerous and should only be performed by qualified people in safety conditions.
NOTE: The card is preset with the standard working times, therefore the automation can be started even without the times programming, simply by adjusting the timing on the display (see default times).
1)Turn off electricity, release the motors and manually position the leaves on halfway. Reset the mechanical lock.
2)Connect the control board to the power supply
3)Select on the on-board display or JOLLY programmer, the type of motor that you are using as indicated in the dispaly management.
4)If necessary also set the operation logic and the other parameters. If you want to program with a transmitter, store a transmitter before programming.
UU 5) Select PROGra ing on the display, press OK and than one of the UP or DOWN buttons.
(If the motor starts in opening, remove and re-put power supply, select on the display reuerse Uotor. And through the UP and DOWN button put it on ON, or if you have the Jolly programmer, activate the motor exchange function. ) 6) At this point the gate will start the following cycle: CLOSING - OPENING - CLOSING.
During cycle, to store the respective stops, press UP or DOWN or START at every point of stop of the leaf. 7) The self-learning is done.
SELFLERNING OPERATION TIME WITH ENCODER
When an encoder is installed, it is necessary to select On in the En(oder menu, start programming and make sure that leaf starts as first in closing. The gate will automatically execute the following cycle: CLOSING - OPENING - CLOSING.
Note: For stop detection sensitivity setting refer to the special menu.
SELFLEARNING OPERATION TIME WITH AMPEROMETRIC SENSOR (For electromechanical motors only)
The times learning can be done only on electromechanical gates, taking advantage of the automatic detection of the stops.
Once the programming has been started just make sure that the gate executes the following cycle: CLOSING - OPENING - CLOSING.
Note: For stop detection sensitivity setting refer to the special menu.
26 |
67410182 |
Rev.06 - 09/2014 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
FUNCTION LOGIC
AUTOMATIC LOGIC
A start impulse opens the gate. A second impluse during the opening will not be accepted. A start impulse during closing reverses the movement.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semiautomatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item Startin pavse and choosing ON or OFF. By default, the parameter is OFF.
SECURITY LOGIC
A start impulse opens the gate. A second impulse during opening reverses the movement. A start impulse during closing reverses the movement.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semiautomatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item Startin pavse and choosing ON or OFF. By default, the parameter is OFF.
STEP BY STEP TYPE 1 LOGIC
The start impulse follows the OPEN-STOP-CLOSE-STOP-OPEN logic.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semiautomatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item Startin pavse and choosing ON or OFF. By default, the parameter is OFF.
STEP BY STEP TYPE 2 LOGIC
The start impulse follows the OPEN-STOP-CLOSE -OPEN logic.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semiautomatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item Startin pavse and choosing ON or OFF. By default, the parameter is OFF.
DEAD MAN LOGIC
The gate opens as long as the START button of opening is pressed; releasing it the gate stops. The gate closes as long as the button connected to the PEDESTRIAN START is pressed; releasing it the gate stops. To execute complete opening and/or closing cycles the related pushbuttons must be constantly pressed.
2 PUSHBUTTONS LOGIC
One start opens, one pedestrian start closes. In opening the closing will not be accepted. In closing a start command reopens, a pedestrian start command (closes) will be ignored.
67410182 |
Rev.06 - 09/2014 |
27 |
®
English |
GATE 1 DG R1 |
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SPECIAL MENU
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
DOWN UP
SPECIAL MENU FUNCTIONS TABLE GATE 1 DG R1
For entering into the special menu move on one of the menu and press the UP and DOWN buttons at the same time for 5 s. For exiting the special menu press END or move on one of the menu and press the UP and DOWN buttons at the same time for 5 s.
MENU SP
1 - open ng torq 1 *
2 - (los ng torq 1 *
3 - Pvshouer
4 - pvsk ng stroke
5- open ng sloudoun
6- (los ng sloudoun
7 - preflasx ng
8 - flasx ng l gxt
9 - reuerse |
U |
otor |
|
|
|||
10 - EN(ODER * |
|||
|
|
|
u |
|
|
|
|
|
11 - opening ti e |
||
|
|
|
u |
|
12 - (losing ti e |
||
|
|
|
|
10 - EN(ODER *
11 - en(oder tot.
12 - en(oder par.
13 - (ourtesy l gxt
14 - traff ( l gxt reseruat on
|
|
SET |
Description |
Default |
Set value |
|
|
|
|
Opening torque |
|
|
|
10 |
100 |
Note: with hydraulic motors |
75 |
|
||
|
|
|
the torque will be on 100% |
|
|
|
|
|
|
Closing torque |
|
|
|
10 |
100 |
Note: with hydraulic motors |
75 |
|
||
|
|
|
the torque will be on 100% |
|
|
|
Off |
|
Disabled |
|
|
||
Open ng and (los ng |
Opening an closing |
Off |
|
|||
|
|
|
|
|
||
Only open ng |
Opening only |
|
||||
|
|
|||||
|
|
|
|
|||
Only (los ng |
Closing only |
|
|
|||
|
|
|
|
|||
Off 3 |
From OFF to 3 seconds |
Off |
|
|||
Off 50 |
From OFF to 50% of |
20 |
|
|||
the stroke |
|
|||||
|
|
|
|
|
||
Off 50 |
From OFF to 50% of |
20 |
|
|||
the stroke |
|
|||||
|
|
|
|
|
||
Only (los ng |
Pre-flashing only |
|
|
|||
active before closing |
Off |
|
||||
|
|
|
|
|||
0.0 |
5.0 |
Pre-flashing time |
|
|
||
NorUal |
Normal |
|
|
|||
|
|
|
|
|||
L gxt |
Control lamp |
U |
|
|||
|
|
|
|
|
||
|
|
|
|
|
||
aluays |
Always ON |
Nor al |
|
|||
|
|
|||||
bvzzer |
Buzzer |
|
|
|||
Off |
|
Synchronized right motor |
Off |
|
||
On |
|
Synchronized left motor |
|
|||
|
|
|
||||
|
|
|
In ON enables the |
|
|
|
OFF |
|
Encoder, in OFF |
Off |
|
||
|
|
|
it's disabled |
|
|
|
|
xxx.s |
Indicates the working times selflearning |
||||
|
in opening and closing. |
|
|
|||
|
|
|
|
|
||
xxx.s |
With UP or DOWN it is possible to increase |
|||||
or reduce the working times. |
||||||
|
|
|
||||
|
|
|
In ON enables the |
|
|
|
ON |
|
Encoder, in OFF |
Off |
|
||
|
|
|
it's disabled |
|
|
|
Xxx. |
|
Encoder impulses stored in programming |
||||
Xxx. |
|
Encoder impulses during operation |
||||
|
N (y(le |
Courtesy light in cycle |
|
|
||
|
|
|
|
20 |
|
|
1 |
240 |
Courtesy light setting |
|
|||
|
|
|||||
from 1s to 4min. |
|
|
||||
|
|
|
|
|
||
|
|
|
When setting this function |
|
|
|
|
|
|
the pedestrian input will be |
|
|
|
Off on |
activated to work on the |
Off |
|
|||
|
|
|
auxiliary board SEM |
|
|
|
|
|
|
(traffic light management). |
|
|
Note: If the encoder is off, the menus 11and 12 will indicate the "Opening time" and the "Closing Time".
28 |
67410182 |
Rev.06 - 09/2014 |
®
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
MENU SP
15 - pedestr an open ng
16- pedestr an PAvSE
17- a((elerat on
18- U a ntenan(e (y(les
19- perforUed (y(les
20 - t |
U |
er |
21 - f re su t(k
22 - EDGE
23 - EDGE
24 - PKOTO1
67410182
English |
GATE 1 DG R1 |
|
SET |
Description |
Default |
Set value |
5 |
100 |
Setting from 20 to 100 |
100 |
|
|
|
Pause in pedestrian |
|
|
= start |
opening same as in |
|
|
|
|
|
total opening |
= start |
|
Off |
Disabled |
|
|
|
1 |
240 |
Setting from 1s to 4 min. |
|
|
0 |
100 |
Acceleration ramp |
100% |
|
100 |
10e4 |
Setting from 100 to |
10e4 |
|
100000 |
|
|||
|
|
|
|
|
|
|
Reports the executed |
|
|
0 10e9 |
cycles. Keep pressed OK |
0 |
|
|
|
|
to reset the cycles |
|
|
off |
Disabled |
|
|
|
ON PXOTO2 |
Timer function active |
|
|
|
on photocell 2 |
off |
|
||
|
|
|
||
ON PEDESTR AN ENTRY |
Timer function active on |
|
|
|
pedestrian input |
|
|
||
|
|
|
|
|
off |
Disactivated |
|
|
|
ON PKOTO2 |
Active on Photo 2 |
off |
|
|
ON PEDESTR AN ENTRY |
Active on pedestrian |
|
|
|
OPEN NG AND (LOS NG |
Active in opening |
OPEN NG |
|
|
|
|
and closing |
|
|
|
|
AND |
|
|
ONLY OPEN NG |
Active only in opening |
|
||
(LOS NG |
|
|||
ONLY (LOS NG |
Active only in closing |
|
||
|
|
|||
|
U |
Normal N.C. contact |
|
|
Nor al |
U |
|
||
|
|
Edge is active and |
|
|
8x2 |
Nor al |
|
||
protected by a 8k2 resistor |
|
|
||
|
|
|
|
|
(LOS NG |
Photocell active in closing |
|
|
|
OPEN NG |
Photocell active in opening |
|
|
|
stop |
Photocell active before |
|
|
|
opening |
|
|
||
|
|
|
|
|
Stop AND (LOSE |
The photocell stops in closing |
|
|
|
and closes when released |
|
|
||
|
|
|
|
|
|
|
The photocell gives a |
|
|
(LOSE |
command to close during |
|
|
|
opening, pause and |
|
|
||
|
|
|
|
|
|
|
closing |
(LOS NG |
|
PAUSE RELOAD |
The photocell charging |
|
|
|
the pausing time |
|
|
||
|
|
|
|
|
|
|
Until occupied, with open |
|
|
Skadou loop |
gate, it prevents reclosing. |
|
|
|
It is switched off during |
|
|
||
|
|
|
|
|
|
|
closing. |
|
|
|
|
If the photocell is occupied |
|
|
|
|
during opening, pause or |
|
|
|
u |
closing, the gate reopens |
|
|
Delay pause ti e |
completely and closes |
|
|
|
|
|
|
|
|
|
|
without observing the |
|
|
|
|
pause time. |
|
|
|
Rev.06 - 09/2014 |
|
29 |