Schneider Electric EER70600 Installation Manual

S/N : RN-2015-W18-2-0119 MAC : 00:80:F4:8F:81:84
Wiser Link MIP EER70600
1
NHA5614301-02
This instruction sheet must be kept for further use. Visit our website www.clipsal.com to download the technical documents of Wiser Link products.
PLEASE NOTE
b This equipment must be installed and maintained by a qualied electrician. b All relevant local, regional and national regulations must be followed during the installation and the use of this equipment. b The manufacturer assumes no responsibility in case of failure to follow the instructions given in this document.
Wiser Link MIP
EER70600
Wiser Link MIP (IP communication module)
Description
2
A
Power supply connector
G
BA
S/N : RN-2015-W18-2-0119
MAC : 00:80:F4:8F:81:84
Wiser Link MIP
C D
EER70600
E
F
54 mm
A
Power supply (Neutral - Line)
A
Communication connector
B
Connection to Wiser Link EM5.
A
Communication indicators
C
Status:
Green: normal operation
Green ashing: rmware upgrade in progress / Button (E) pressed Orange: product gets a fallback IP / Directly connected to
a computer
Orange ashing: startup
Red: duplicated IP on the network or IP conguration issue LED off: product not powered
(Ethernet):
Green ashing: Ethernet 100 Mbit/s
Orange ashing: Ethernet 10 Mbit/s
LED off: no communication detected
A
D
QR code to access Wiser Link Application
A
E
Button
b Reset password b User registration
A
F
RJ45 Ethernet Connection
A
G
Device Serial number and MAC address
Released for Manufacturing
Printed on 2016/02/27
1/4NHA5614301-02
2
y
< 50 m
Wiser Link MIP
EER70600
Wiser Link EM5
Installation
3
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
b Disconnect all power before installing this equipment. b Use only insulated tools to connect the Wiser Link MIP to the Wiser Link EM5 energy meter.
Failure to follow these instructions will result in death or serious injury.
DANGER
Wiser Link MIP
Wiser Link MIP
EER70600
1
EER70600
Click!
Wiring
4
NOTICE
HAZARD OF EQUIPMENT DAMAGE
b Plug the power-supply connector (Neutral-Line) into the power-supply socket with marking N-L on the MIP product. b Plug the communication connector (communication link with Wiser Link EM5) into the communication socket with marking .
Failure to follow these instructions can result in equipment damage.
4.1 Wiring between the Wiser Link MIP and Wiser Link EM5
N L
10 A
N L
y 10 A
1 23 45 6
4.2 Operational wiring
Wiser Link MIP
EER70600
Wiser Link system inside electrical switchboard
*Ethernet cable
(Not part of Wiser Link MIP package)
< 50 m
Released for Manufacturing
Printed on 2016/02/27
7 89 10 11 12 13 14 15 16
Modem installed in the living space
Wiser Link EM5
*PLEASE NOTE:
If no modem is available during installation, then ethernet cable from Wiser Link MIP to an expected location of modem should
still be installed.
Reference standard AS/NZS 3000 and TS009.
2/4NHA5614301-02