Rudd RGTC-06EMAES Manual

4.5 (6)

FORM NO. G11-502

Supersedes Form No. G11-502 Rev. 10

GAS FURNACES

RGTCSERIES

Models with Input Rates

from 45,000 to 105,000 BTU/HR [13.19 to 30.77 kW]

(All Models up to 95% A.F.U.E. )

“Visit www.Rheem.com for complete details.”

CLASSIC® 90 PLUS®

UP TO 95% A.F.U.E. DOWNFLOW/ HORIZONTAL GAS FURNACES

The Rheem® Classic® 90 Plus® High Efficiency line of downflow/horizontal gas furnaces are designed for utility rooms, closets, alcoves, attics or crawl spaces. The RGTC is shipped in the downflow configuration and is easily converted for horizontal left-hand airflow applications.

The design is certified by CSA.

Features

Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue reliability.

Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories.

Top electrical connections, left or right gas and condensate drainage connections on downflow models.

Condensate drain for horizontal application provided standard.

Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner.

An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today.

Pre-paint galvanized steel cabinet.

Molded permanent filters.

Optional indoor or outdoor combustion air.

Transformer and control fuse protection.

Control board diagnostics.

A variety of cooling coils and plenums designed to use with the Classic 90 Plus gas furnaces are available as optional accessories for air conditioning models.

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

Rudd RGTC-06EMAES Manual

CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/HORIZONTAL

GAS FURNACE

FUSE PROTECTION

PRESSURE SWITCH

PRIMARY AND SECONDARY

HEAT EXCHANGER

IN-SHOT BURNERS

STANDARD EQUIPMENT

Completely assembled and wired; heat exchanger; primary: 409 and aluminized 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)

INTEGRATED

FURNACE

CONTROL

DRAFT INDUCER

GAS VALVE AND

MANIFOLD

DIRECT SPARK IGNITION

REMOTE SENSOR

OPTIONAL EQUIPMENT

NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas.

All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.

For L.P. (propane) operation, refer to Conversion Kit Index Form.

WARNING

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

2 Rheem Heating, Cooling and Water Heating

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS

DOWNFLOW/HORIZONTAL MODELS U.S. and Canadian Models

MODEL NUMBERS

RGTC-04EMAES

RGTC-06EMAES

RGTC-07ERBGS

RGTC-09EZAJS

RGTC-10ERBJS

INPUT-BTU/HR [kW]

45,000 [13.19]

60,000 [17.58]

75,000 [21.98]

90,000 [26.38]

105,000 [30.77]

HEATING CAPACITY BTU/HR [kW]

41,000 [12.02]

56,000 [16.41]

69,000 [20.22]

84,000 [24.62]

97,000 [28.43]

HIGH ALTITUDE INPUT [kW]

40,500 [11.87]

54,000 [15.83]

67,500 [19.78]

81,000 [23.74]

94,500 [27.70]

HIGH ALTITUDE OUTPUT

37,000 [10.84]

50,400 [14.77]

63,000 [18.46]

75,000 [21.98]

87,500 [25.64]

CAPACITY [kW]

 

 

 

 

 

BLOWER (D x W) [mm]

11 x 7 [279 x 178]

11 x 7 [279 x 178]

11 x 10 [279 x 254]

12 x 11 [305 x 279]

11 x 10 [279 x 254]

MOTOR H.P. [W]

1/2 [373]-4-PSC

1/2 [373]-4-PSC

1/2 [373]-4-PSC

3/4 [559]-4-PSC

3/4 [559]-4-PSC

SPEEDS-TYPE

 

 

 

 

 

 

 

 

 

 

 

MOTOR FULL LOAD AMPS

6.8

6.8

6.8

9.5

9.5

 

 

 

 

 

 

HEATING SPEED

MED-LOW

MED-HI

MED-HI

MED-HI

MED-HI

 

 

 

 

 

 

COOLING SPEED

HIGH

HIGH

HIGH

HIGH

HIGH

 

 

 

 

 

 

HEAT EXT. STATIC PRESSURE

.10 [.025]

.12 [.029]

.12 [.029]

.15 [.037]

.20 [.049]

(IN. W.C.) [kPa]

 

 

 

 

 

 

 

 

 

 

 

RATED EXT. STATIC PRESSURE

.50 [.124]

.50 [.124]

.50 [.124]

.50 [.124]

.50 [.124]

(IN. W.C.) [kPa]

 

 

 

 

 

 

 

 

 

 

 

HEATING CFM @ .2" W.C.

866 [409]

1122 [530]

1516 [716]

1698 [802]

1812 [856]

E.S.P. [L/s]

 

 

 

 

 

COOLING CFM @ .5" W.C.

1220 [576]

1242 [586]

1559 [736]

1850 [873]

1977 [934]

E.S.P. [L/s]

 

 

 

 

 

TEMPERATURE RISE RANGE

30-60 [16.7-33.3]

30-60 [16.7-33.3]

30-60 [16.7-33.3]

30-60 [16.7-33.3]

35-65 [19.4-36.1]

°F [°C]

 

 

 

 

 

STANDARD FILTER [mm]

(2) 12" x 20"

(2) 12" x 20"

(2) 12" x 20"

(2) 12" x 20"

(2) 14" x 20"

[305 x 508]

[305 x 508]

[305 x 508]

[305 x 508]

[356 x 508]

 

APPROX. SHIPPING WEIGHT

111

117

137

148

160

(LBS.) [kg]

 

 

 

 

 

AFUE

95.0%

95.0%

95.0%

95.0%

95.0%

NOTES: All models are 115V, 60HZ, 1ø. Gas connection size for all models is 1/2" [13 mm] N.P.T.See Conversion Kit Index Form for high altitude derate.

Canadian installations only.

In accordance with D.O.E. test procedures.

MODEL IDENTIFICATION

R

 

G

 

T

 

C

 

 

 

06E

 

 

M

 

A

 

E

 

S

Rheem

Gas

Downflow/

Design

 

 

 

Heating Input

Blower Size

Variations

Heat/Cool

Fuel Code

 

 

Furnace

Horizontal

Series

 

 

 

Designation

M = 11 x 7

A = Std.

Designation

S = U.S. and

 

 

 

 

Condensing

 

 

Electric

 

Input

[279 x 178 mm]

B = Wide

E = 1100-1300 CFM

Canadian Natural

 

 

 

 

Gas Furnace

 

 

 

R = 11 x 10

Cabinet

[519-613.5 L/s]

Gas

 

 

 

 

 

 

Ignition

 

BTU/HR

 

 

 

 

 

 

 

 

 

[279 x 254 mm]

 

 

G = 1500-1700 CFM

 

 

 

 

 

 

 

 

 

 

04E

 

 

45,000

[13 kW]

 

 

 

 

 

 

 

 

 

 

 

 

 

Z = 12 x 11

 

 

[707.9-802.3 L/s]

 

 

 

 

 

 

 

 

 

 

06E

60,000

[17.6 kW]

[305 x 279 mm]

 

 

J = 1900-2100 CFM

 

 

 

 

 

 

 

 

 

 

07E

75,000

[20.5 kW]

 

 

 

 

[896.7-991.1 L/s]

 

 

 

 

 

 

 

 

 

 

09E

90,000

[26.4 kW]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10E

105,000

[30.7 kW]

 

 

 

 

 

 

 

[ ] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product

Primary and Secondary Heat Exchanger.......Limited Lifetime

which fails in normal use and service within the applicable

Conditional Parts (Registration Required) .......Ten (10) Years

period stated, in accordance with the terms of the limited

 

warranty.

 

For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.

Rheem Heating, Cooling and Water Heating

3

Loading...