FORM NO. G11-502
Supersedes Form No. G11-502 Rev. 10
GAS FURNACES
RGTCSERIES
Models with Input Rates
from 45,000 to 105,000 BTU/HR [13.19 to 30.77 kW]
(All Models up to 95% A.F.U.E. )
“Visit www.Rheem.com for complete details.”
CLASSIC® 90 PLUS®
UP TO 95% A.F.U.E. DOWNFLOW/ HORIZONTAL GAS FURNACES
The Rheem® Classic® 90 Plus® High Efficiency line of downflow/horizontal gas furnaces are designed for utility rooms, closets, alcoves, attics or crawl spaces. The RGTC is shipped in the downflow configuration and is easily converted for horizontal left-hand airflow applications.
The design is certified by CSA.
Features
■Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue reliability.
■Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories.
■Top electrical connections, left or right gas and condensate drainage connections on downflow models.
■Condensate drain for horizontal application provided standard.
■Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner.
■An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today.
■Pre-paint galvanized steel cabinet.
■Molded permanent filters.
■Optional indoor or outdoor combustion air.
■Transformer and control fuse protection.
■Control board diagnostics.
A variety of cooling coils and plenums designed to use with the Classic 90 Plus gas furnaces are available as optional accessories for air conditioning models.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.
CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/HORIZONTAL
GAS FURNACE
FUSE PROTECTION
PRESSURE SWITCH
PRIMARY AND SECONDARY
HEAT EXCHANGER
IN-SHOT BURNERS
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: 409 and aluminized 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)
INTEGRATED
FURNACE
CONTROL
DRAFT INDUCER
GAS VALVE AND
MANIFOLD
DIRECT SPARK IGNITION
REMOTE SENSOR
OPTIONAL EQUIPMENT
NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas.
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
2 Rheem Heating, Cooling and Water Heating
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
DOWNFLOW/HORIZONTAL MODELS U.S. and Canadian Models
MODEL NUMBERS |
RGTC-04EMAES |
RGTC-06EMAES |
RGTC-07ERBGS |
RGTC-09EZAJS |
RGTC-10ERBJS |
|
INPUT-BTU/HR [kW] |
45,000 [13.19] |
60,000 [17.58] |
75,000 [21.98] |
90,000 [26.38] |
105,000 [30.77] |
|
HEATING CAPACITY BTU/HR [kW] |
41,000 [12.02] |
56,000 [16.41] |
69,000 [20.22] |
84,000 [24.62] |
97,000 [28.43] |
|
HIGH ALTITUDE INPUT [kW] |
40,500 [11.87] |
54,000 [15.83] |
67,500 [19.78] |
81,000 [23.74] |
94,500 [27.70] |
|
HIGH ALTITUDE OUTPUT |
37,000 [10.84] |
50,400 [14.77] |
63,000 [18.46] |
75,000 [21.98] |
87,500 [25.64] |
|
CAPACITY [kW] |
||||||
|
|
|
|
|
||
BLOWER (D x W) [mm] |
11 x 7 [279 x 178] |
11 x 7 [279 x 178] |
11 x 10 [279 x 254] |
12 x 11 [305 x 279] |
11 x 10 [279 x 254] |
|
MOTOR H.P. [W] |
1/2 [373]-4-PSC |
1/2 [373]-4-PSC |
1/2 [373]-4-PSC |
3/4 [559]-4-PSC |
3/4 [559]-4-PSC |
|
SPEEDS-TYPE |
||||||
|
|
|
|
|
||
|
|
|
|
|
|
|
MOTOR FULL LOAD AMPS |
6.8 |
6.8 |
6.8 |
9.5 |
9.5 |
|
|
|
|
|
|
|
|
HEATING SPEED |
MED-LOW |
MED-HI |
MED-HI |
MED-HI |
MED-HI |
|
|
|
|
|
|
|
|
COOLING SPEED |
HIGH |
HIGH |
HIGH |
HIGH |
HIGH |
|
|
|
|
|
|
|
|
HEAT EXT. STATIC PRESSURE |
.10 [.025] |
.12 [.029] |
.12 [.029] |
.15 [.037] |
.20 [.049] |
|
(IN. W.C.) [kPa] |
||||||
|
|
|
|
|
||
|
|
|
|
|
|
|
RATED EXT. STATIC PRESSURE |
.50 [.124] |
.50 [.124] |
.50 [.124] |
.50 [.124] |
.50 [.124] |
|
(IN. W.C.) [kPa] |
||||||
|
|
|
|
|
||
|
|
|
|
|
|
|
HEATING CFM @ .2" W.C. |
866 [409] |
1122 [530] |
1516 [716] |
1698 [802] |
1812 [856] |
|
E.S.P. [L/s] |
||||||
|
|
|
|
|
||
COOLING CFM @ .5" W.C. |
1220 [576] |
1242 [586] |
1559 [736] |
1850 [873] |
1977 [934] |
|
E.S.P. [L/s] |
||||||
|
|
|
|
|
||
TEMPERATURE RISE RANGE |
30-60 [16.7-33.3] |
30-60 [16.7-33.3] |
30-60 [16.7-33.3] |
30-60 [16.7-33.3] |
35-65 [19.4-36.1] |
|
°F [°C] |
||||||
|
|
|
|
|
||
STANDARD FILTER [mm] |
(2) 12" x 20" |
(2) 12" x 20" |
(2) 12" x 20" |
(2) 12" x 20" |
(2) 14" x 20" |
|
[305 x 508] |
[305 x 508] |
[305 x 508] |
[305 x 508] |
[356 x 508] |
||
|
||||||
APPROX. SHIPPING WEIGHT |
111 |
117 |
137 |
148 |
160 |
|
(LBS.) [kg] |
||||||
|
|
|
|
|
||
AFUE |
95.0% |
95.0% |
95.0% |
95.0% |
95.0% |
NOTES: All models are 115V, 60HZ, 1ø. Gas connection size for all models is 1/2" [13 mm] N.P.T.See Conversion Kit Index Form for high altitude derate.
Canadian installations only.
In accordance with D.O.E. test procedures.
MODEL IDENTIFICATION
R |
|
G |
|
T |
|
C |
|
— |
|
|
06E |
|
|
M |
|
A |
|
E |
|
S |
|
Rheem |
Gas |
Downflow/ |
Design |
|
|
|
Heating Input |
Blower Size |
Variations |
Heat/Cool |
Fuel Code |
||||||||||
|
|
Furnace |
Horizontal |
Series |
|
|
|
Designation |
M = 11 x 7 |
A = Std. |
Designation |
S = U.S. and |
|||||||||
|
|
|
|
Condensing |
|
|
Electric |
|
Input |
[279 x 178 mm] |
B = Wide |
E = 1100-1300 CFM |
Canadian Natural |
||||||||
|
|
|
|
Gas Furnace |
|
|
|
R = 11 x 10 |
Cabinet |
[519-613.5 L/s] |
Gas |
||||||||||
|
|
|
|
|
|
Ignition |
|
BTU/HR |
|||||||||||||
|
|
|
|
|
|
|
|
|
[279 x 254 mm] |
|
|
G = 1500-1700 CFM |
|
||||||||
|
|
|
|
|
|
|
|
|
04E |
|
|
45,000 |
[13 kW] |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
Z = 12 x 11 |
|
|
[707.9-802.3 L/s] |
|
||||||||
|
|
|
|
|
|
|
|
|
06E |
60,000 |
[17.6 kW] |
[305 x 279 mm] |
|
|
J = 1900-2100 CFM |
|
|||||
|
|
|
|
|
|
|
|
|
07E |
75,000 |
[20.5 kW] |
|
|
|
|
[896.7-991.1 L/s] |
|
||||
|
|
|
|
|
|
|
|
|
09E |
90,000 |
[26.4 kW] |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
10E |
105,000 |
[30.7 kW] |
|
|
|
|
|
|
|
[ ] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product |
Primary and Secondary Heat Exchanger.......Limited Lifetime |
which fails in normal use and service within the applicable |
Conditional Parts (Registration Required) .......Ten (10) Years |
period stated, in accordance with the terms of the limited |
|
warranty. |
|
For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.
Rheem Heating, Cooling and Water Heating |
3 |