Rudd 22V30F Manual

4.5 (2)
Rudd 22V30F Manual

Fury® Gas Water Heaters

Available in 29, 38, 40 and 50 Gallon Tall – 30, 40 and 50 Gallon Short Gas Models

Get

4 MORE YEARS

with ProtectionPlus

6-year Limited Tank and Parts Warranty*

With ProtectionPlusthe 6-year Limited Tank Warranty Becomes 10 years!

Guardian System

One-of-a-kind air/fuel shut-off device offers double protection

Maintenance free – no filter to clean

Standard replacement parts

Environmentally Friendly Burner

Low NOx design for low nitrous oxide emissions

Self-Cleaning

EverKleenpatented system fights sediment build-up

Reduces fuel costs

Provides more hot water

Easy to Light

No matches required

Energy Efficient

More hot water at low operating cost

Longer Life

Patented magnesium anode rod design ncorporatesi a special resistor that protects the tank from rust

High Altitude Compliant

All models are certified for applications up to 6,000 feet above sea level. Some models are certified up to

10,200 feet above sea level. Check factory for listings

Plus…

Brass drain valve and temperature and pressure relief valve are included

Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements

HE High Efficiency Models Feature:

High performance and lower operating cost

Compliant with many gas utility incentive programs

*See Residential Warranty Certificate for complete warranty information.

Energy Factor and Average Annual Operating

 

 

®

 

 

 

Costs based on D.O.E. (Department of Energy)

 

 

 

test procedures. D.O.E. national average fuel

 

 

 

rate natural gas $1.218/therm; LP $1.87/gallon.

 

 

 

 

 

 

DESCRIPTION

 

 

FEATURES

 

 

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

 

ENERGy INFO.

 

T

 

 

 

 

 

 

 

 

 

 

HT. TO

 

WATER

HT. TO

 

 

 

 

 

 

 

GAS INPUT IN

RECOVERy IN

FIRST HOUR

HT. TO

TANK

 

GAS

VENT

CONN.

SIDE

WATER

SHIP.

ENERGy

AVG. ANN.

 

y

 

 

 

 

GAL.

 

THOUS. BTU/HR.

G.P.H. 90° RISE

DEL. G.P.H.

VENT

HT.

DIAM.

CONN.

SIZE

CNTR.

T&P

CONN.

WT.

FACTOR

OPER. COST

 

P

 

 

E

CAP.

MODEL NUMBER

NAT.

LP

NAT.

LP

NAT.

A

B

C

D

E

F

G

H

(LBS)

NAT.

NAT.

H

TALL

40

42VR40-40F

40

34

40.4

34.3

68

63-1/4

59-3/4

21

14-1/2

3

8

53-1/2

3/4

135

0.62

$294

50

42VR50-40F

40

36

40.4

36.4

83

62-1/4

58-3/4

23

14-1/2

3

8

52-1/2

3/4

165

0.62

$294

E

 

 

 

29

22V30F

32

30

32.3

30.3

50

59-3/4

56-3/8

16-1/8 14-1/2

3

8

50-3/4

3/4

100

0.62

$294

 

 

40

22V40-36F1

36

36.4

67

61-1/2

58

17-3/4 14-1/2

3

8

53

3/4

120

0.59

$309

 

T

40

22V40F1

38

32

38.4

32.3

73

61-3/4

58-3/8

18-1/8

14-1/2

3

8

52-1/4

3/4

120

0.59

$309

 

A

38

42V40F

40

34

40.4

34.3

68

61-1/2

57-3/4

19-3/4

14-1/2

3

8

52-1/4

3/4

125

0.60

$304

 

L

 

50

22V50F1

38

36

38.4

36.4

90

61-1/2

58-1/4

20-1/8 14-1/2

3

8

51-3/8

3/4

130

0.58

$315

 

L

 

 

50

42V50-40F

40

36

40.4

36.4

82

61-1/2

58

21-3/4 14-1/2

3

8

52-1/2

3/4

150

0.58

$315

 

 

50

42V50-50F

50

50.5

81

62

58

21-3/4 14-1/2

4

8

52-1/2

3/4

150

0.58

$315

 

 

30

22V30S-30F

30

30.3

50

49-3/4

46-1/4

19-3/4

14-1/2

3

8

40-1/4

3/4

98

0.61

$299

 

S

40

42VR40S-40F

40

36

40.4

36.4

72

53-7/8

50-1/2

23

14-1/2

3

8

44

3/4

135

0.62

$294

 

H

 

40

22V40SF

36

34

36.4

34.3

72

52-3/4

49-3/8

20-1/8

14-1/2

3

8

42-3/4

3/4

130

0.59

$309

 

O

 

R

40

42V40SF

40

36

40.4

36.4

72

53-7/8

50-1/2

20-1/8

14-1/2

3

8

44

3/4

130

0.59

$309

 

T

 

50

42V50SF

40

36

40.4

36.4

84

54-1/4 49-3/4 22-1/4 14-1/2

3

8

44

3/4

158

0.59

$309

 

 

 

SPECIFy LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: 42VR40-40PF.

 

 

 

 

 

 

 

 

• 40 ng/J NOx Compliant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rheem Guardian System Features…

 

 

 

 

 

 

FLUE

ANODE ROD

 

 

 

 

 

 

 

H

H

 

 

 

HOT

 

 

 

COLD

 

 

 

WATER

 

 

 

WATER

 

 

 

CONNECTION

 

 

 

CONNECTION

 

 

 

 

Exclusive Combustion

 

 

 

F

Flame Arrestor Plate

Maintenance Free

 

E

Shut-off System

 

3/4" N.P.T.

Should a spill ncidenti occur, the Guardian

A specially-designed flame arrestor

Superior air filtration prevents the

 

RELIEF

 

VALVE

System shuts off the gas supply and the air

prevents ignition of vapors outside the

flame arrestor from becoming clogged

 

OPENING

supply preventing a sustained vapor burn

combustion chamber.

by lint, dust and oil.

 

 

in the combustion chamber.

 

 

 

 

 

 

 

C

These units are designed to meet or exceed ANSI

 

 

 

(American National Standards Institute) requirements and

 

A B

 

have been tested according to D.O.E. test procedures and

 

 

 

meet or exceed the energy efficiency requirements of

 

1/2"

G

NAECA, ASHRAE standard 90, ICC Code and all state

 

 

 

energy efficiency performance criteria for energy

Y E A R L I M I T E D

 

 

consuming appliances.

TANK WARRANTY

D

 

 

6BECOMES10

 

Before purchasing this appliance, read important energy

 

 

cost and efficiency information available from your supplier.

For more details, see form 101-7.

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com

PRINTED IN U . S . A

12/10 WP

FORM NO . 101 - 6 Rev. 13

Loading...