Rudd RGFD-09EZCM Manual

4 (1)

FORM NO. G11-468 REV. 15

Supersedes Form No. G11-468 Rev. 14

GAS FURNACES

“Visit www.RheemAC.com/ taxcredit for complete details.”

RGFDSERIES

Models with Input Rates

from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kW]

(All Models 92% A.F.U.E.† or Above)

Modulating Furnace

Thermostat

RHC-TST412MDMS

90 PLUS MODULATING UPFLOW GAS FURNACES

WITH CONTOUR COMFORT CONTROL®

The Rheem Prestige Series90 Plus High Efficiency line of upflow gas furnaces are designed for utility rooms, closets, or alcoves. Because of the low-profile 34 inch height, the

RGFDmodel can be used vertically to satisfy most applications that traditionally call for a horizontal furnace.

The design is certified by CSA.

Features

Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue reliability.

Modulating Function: when used with a modulating thermostat, modulation rate between 40% and 100% of total capacity.

Two-stage Function: when used with a two-stage thermostat, furnace operates at 40% on first stage, and stages up to 65%, then 100% for second stage.

Multistage Function: when used with a single-stage thermostat, furnace functions as a three stage furnace operating at 40%, 65% and 100% of total capacity.

Reduced firing rates, electrically efficient ECM2+ motor, and solid doors provide the ultimate in quiet operation.

Low speed constant fan.

Constant temperature rise for superior comfort.

Seven segment LED for system diagnostics.

Diagnostic history for troubleshooting.

Two-speed induced draft motor.

Direct spark ignition with remote sense.

Top electrical connections, left or right gas and condensate drainage connections on downflow models.

Optional indoor or outdoor combustion air.

All models comply with Department of Energy test procedures for 2% or less electrical efficiency ratings.

A variety of cooling coils and plenums designed to use with the Prestige Series90 Plus gas furnaces are available as optional accessories.

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

Rudd RGFD-09EZCM Manual

PRESTIGE SERIES90 PLUS HIGH EFFICIENCY MODULATING UPFLOW GAS FURNACE

REMOTE SENSOR

IN-SHOT BURNERS

DIRECT SPARK IGNITION

PRIMARY AND

SECONDARY

HEAT EXCHANGER

GAS

VALVE

PRESSURE

SWITCHES

IGNITION

CONTROL

INTEGRATED

FURNACE CONTROL

BLOWER ASSEMBLY

DRAFT INDUCER

WITH ECM MOTOR

STANDARD EQUIPMENT

Completely assembled and wired; heat exchanger; primary: 409 and aluminized 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant modulating main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shutoff valve; 100% safety lock out; cool fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; humidifier connections; humidifier on/off delay; dehumidifier connection; low speed continuous fan option; transformer; direct drive, ECM variable speed blower motor. (Please note: a thermostat is not included as standard equipment. See “Accessories”)

OPTIONAL EQUIPMENT

Side and bottom filter racks; return air cabinet for all sizes.

NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas.

All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.

For L.P. (propane) operation, refer to Conversion Kit Index Form. Fossil Fuel Kits for use with Heat Pumps.

WARNING

2 Rheem Heating, Cooling and Water Heating

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS—UPFLOW MODELS

U.S. and Canadian Models

MODEL NUMBERS

RGFD-06EMCK

RGFD-07EMCK

RGFD-09EZCM

RGFD-10EZCM

RGFD-12ERCM

INPUT–MAXIMUM (BTU/HR) [kW]

60,000 [17.58]

75,000 [21.98]

90,000

[26.38]

105,000

[30.77]

120,000

[35.17]

 

 

 

 

 

 

 

 

 

HEATING CAPACITY–MAXIMUM [kW]

55,800 [16.35]

72,000 [21.10]

86,000

[25.20]

100,000

[29.31]

115,000

[33.70]

 

 

 

 

 

 

 

 

 

 

 

INPUT–MINIMUM (BTU/HR) [kW]

24,000

[7.03]

30,000

[8.79]

36,000

[10.55]

42,000

[12.31]

48,000

[14.07]

 

 

 

 

 

 

 

 

 

 

 

HEATING CAPACITY–MINIMUM [kW]

22,560

[6.61]

28,200

[8.26]

33,840

[9.92]

39,000

[11.57]

45,120

[13.22]

HEATING EXT. STATIC PRESSURE [kPa]

0.12

[.029]

0.12

[.029]

0.15

[.037]

0.20

[.049]

0.20

[.049]

BLOWER (D X W IN.) [mm]

11 x 7 [279 x 178]

11 x 7 [279 x 178]

12 x 11 [305 x 279]

12 x 11 [305 x 279]

11 x 10 [279 x 254]

ECM MOTOR HP [W]

1/2 [373]

1/2 [373]

1 [746]

1 [746]

1 [746]

UNIT AMPS

8.7

8.7

12.0

12.0

12.0

MAXIMUM OVERCURRENT PROTECTION

15

15

15

15

15

 

 

 

 

 

 

 

 

 

HEATING CFM–MAXIMUM [L/s]

795

[375]

995

[470]

1195

[564]

1395 [658]

1595 [753]

HEATING CFM–MINIMUM [L/s]

320

[151]

430

[203]

515

[243]

600

[283]

685

[323]

COOLING CFM–RANGE [L/s]

600-1200 [283-566]

600-1200 [283-566]

1200-2000 [566-944]

1200-2000

[566-944]

1200-2000

[566-944]

MAXIMUM EXT. STATIC PRESSURE [kPa]

0.80

[0.20]

0.80

[0.20]

0.80

[0.20]

0.80

[0.20]

0.80

[0.20]

 

 

 

 

 

 

TEMPERATURE RISE RANGE °F [°C]

40-70 [22.2-38.9]

40-70 [22.2-38.9]

40-70 [22.2-38.9]

40-70 [22.2-38.9]

40-70 [22.2-38.9]

 

 

 

 

 

 

MAX OUTLET AIR TEMPERATURE °F [°C]

170 [76.7]

180 [82.2]

180 [82.2]

180 [82.2]

180 [82.2]

RETURN AIR CABINETS–RXGR-

C17B

C17B

C21B

C21B

C24B

 

 

 

 

 

 

 

 

 

 

 

FILTER SIZE (IN.) [mm] BOTTOM

153/4 x 25

[400 x 635]

153/4 x 25

[400 x 635]

191/4 x 25

[489 x 635]

191/4 x 25

[489 x 635]

223/4 x 25

[578 x 635]

FILTER SIZE (IN.) [mm] SIDE

153/4 x 25

[400 x 635]

153/4 x 25

[400 x 635]

153/4 x 25

[400 x 635]

153/4 x 25

[400 x 635]

153/4 x 25

[400 x 635]

APPROX. SHIPPING WEIGHT (LBS.) [kg]

127 [57.6]

133 [60.3]

158 [71.7]

162 [73.5]

170 [77.1]

 

 

 

 

 

 

AFUE

93.4%

92.8%

94.1%

92.4%

92.5%

MODEL IDENTIFICATION

R

G

F

D

 

07E

 

 

 

 

M

 

C

 

K

 

 

S

Rheem

Gas

Modulating

Design

 

 

Heating Input

 

 

 

Blower Size

Variations

Heat/Cool

 

 

Fuel Code

 

 

Furnace

Prestige

Series

 

 

Designation

 

 

M = 11 x

7

 

C = Single/

Designation

 

S = U.S. and

 

 

 

 

Series

 

 

 

 

Electric

 

 

 

 

 

[279 x 178 mm]

Multi Zone

K = 600-1200 CFM

 

 

Canadian

 

 

 

 

90 Plus

 

 

 

 

 

 

 

 

R = 11 x

10

 

 

 

[283-566 L/s]

 

 

Natural Gas

 

 

 

 

 

 

Electric

Ignition—

 

Input

 

 

 

 

 

 

 

 

 

Gas Furnace

 

 

 

 

[279 x 254 mm]

 

 

M = 1200-2000 CFM

 

 

 

 

 

 

Ignition

Nox Models

 

BTU/HR

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

= 12 x

11

 

 

 

[566-944 L/s]

 

 

 

 

 

 

 

 

 

 

 

 

 

06E

06N

60,000

[17.6 kW]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[305 x 279 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07E

07N

75,000

[20.5 kW]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09E

09N

90,000

[26.4 kW]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10E

10N

105,000

[30.7 kW]

 

 

 

 

 

 

 

 

Option 278

 

 

 

 

 

 

 

 

 

 

12E

120,000 [35.2 kW]

 

 

 

 

 

 

 

278 = Factory Supplied

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[ ] Designates Metric Conversions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Altitude

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion Kit