Rudd 90RJ04EES01 Manual

4.5 (12)

FORM NO. G11-477 REV. 8

Supersedes Form No. G11-477 Rev. 7

90RJ SERIES

Models with Input Rates

from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kW]

(All Models 90% A.F.U.E.† or Above)

90 HIGH EFFICIENCY UPFLOW

GAS FURNACES

The Rheem Value Series 90 High Efficiency line of upflow gas furnaces are designed for utility rooms, closets, or alcoves. Because of the low-profile 34 inch height, the

90RJ model can be used vertically to satisfy most applications that traditionally call for a horizontal furnace.

The design is certified by the CSA.

Features

Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories.

Left or right side gas, electric, and condensate drainage connections.

Integrated control board manages all operational functions and provides accessory hookups for an electronic air cleaner.

A slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today.

Textured galvanized steel cabinet with painted access doors.

Optional indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or right side of the cabinet on all upflow models. A special molded fitting is provided to ease installation.

Control board diagnostics.

A variety of cooling coils and plenums designed to use with the Rheem Value Series 90 gas furnaces are available as optional accessories for air conditioning models.

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

ENER

UIDE

Annual Fuel Utilization Efficiency - AFUE

THIS MODEL

92.0%

MIDHIGH

78%

82%

88%

97%

Rudd 90RJ04EES01 Manual

RHEEM 90 HIGH EFFICIENCY UPFLOW GAS FURNACE

PRIMARY AND SECONDARY HEAT EXCHANGER

IN-SHOT BURNERS

PRESSURE SWITCH

INTEGRATED

FURNACE

CONTROL

REMOTE

SENSOR

HOT SURFACE IGNITOR

GAS VALVE AND

MANIFOLD

DRAFT INDUCER

STANDARD EQUIPMENT

Completely assembled and wired; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; pressure regulator for natural and L.P. (propane) gases; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)

OPTIONAL EQUIPMENT

(See Accessory Page)

NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas.

All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.

For L.P. (propane) operation, refer to Conversion Kit Index Form.

WARNING

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

2 ICECO

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS

MODEL NUMBERS

90RJ04EES01

90RJ06EES01

90RJ07EES01

90RJ07EFS01

90RJ09EJS01

90RJ10EGS01

90RJ12EHS01

90RJSERIES

 

 

 

 

 

 

 

Input-BTU/Hr [kW]

45,000

60,000

75,000

75,000

90,000

105,000

120,000

[13.19]

[17.58]

[21.98]

[21.98]

[26.37]

[30.77]

[35.17]

 

Heating Capacity

42,000

56,000

70,000

70,000

84,000

97,000

113,000

BTU/Hr [kW]

[12.31]

[16.41]

[20.51]

[20.51]

[24.61]

[28.43]

[33.12]

High Altitude Input

40,500

54,000

67,500

67,500

81,000

94,500

108,000

[kW]

[11.87]

[15.83]

[19.78]

[19.78]

[23.73]

[27.70]

[31.65]

High Altitude Output

37,800

50,400

63,000

63,000

76,000

87,500

100,000

Capacity [kW]

[11.07]

[14.77]

[18.46]

[18.46]

[22.27]

[25.64]

[29.31]

Blower (D x W)

11 x 7

11 x 7

11 x 7

12 x 7

12 x 11

12 x 11

11 x 10

[mm]

[279 x 178]

[279 x 178]

[279 x 178]

[305 x 178]

[305 x 279]

[305 x 279]

[279 x 254]

Motor H.P. [W]

1/2 [373]

1/2 [373]

1/2 [373]

3/4 [559]

1/2 [373]

3/4 [559]

3/4 [559]

Speeds-Type

4-PSC

3-PSC

3-PSC

3-PSC

3-PSC

3-PSC

3-PSC

Motor Full Load Amps

6.8

6.8

6.8

9.5

8.0

9.5

9.5

Heating Speed

Med-Low

Low

Med

Low

Med

Low

Low

Cooling Speed

High

High

High

High

High

High

High

Minimum Ext. Static Pressure

.10 [.025]

.12 [.029]

.12 [.029]

.12 [.029]

.15 [.037]

.20 [.049]

.20 [.049]

(In. W.C.) [kPa]

 

 

 

 

 

 

 

Maximum Ext. Static Pressure

.50 [.12]

.50 [.12]

.50 [.12]

.50 [.12]

.50 [.12]

.50 [.12]

.50 [.12]

(In. W.C.) [kPa]

 

 

 

 

 

 

 

Heating C.F.M. @ .2" [.049 kPa]

885 [417]

845 [398]

1050 [495]

1275 [600]

1465 [691]

1445 [682]

1580 [745]

W.C. E.S.P. [L/s]

 

 

 

 

 

 

 

Cooling C.F.M. @ .5" [.124 kPa]

1195 [564]

1100 [519]

1110 [524]

1540 [725]

1580 [746]

1810 [854]

1900 [897]

W.C. E.S.P. [L/s]

 

 

 

 

 

 

 

Temperature Rise

30-60

40-70

45-75

40-70

35-65

50-80

50-80

Range °F [°C]

[16.7-33.3]

[22.2-38.9]

[25-41.7]

[22.2-38.9]

[19.4-36.1]

[27.8-44.4]

[27.8-44.4]

Return Air Cabinets (Opt.)

C17B

C17B

C17B

C21B

C21B

C21B

C24B

RXGR-

Filter Size

(2) 12" x 16"

(2) 12" x 16"

(2) 12" x 16"

(2) 12" x 20"

(2) 12" x 16"

(2) 12" x 16"

(2) 24" x 16"

[mm]

[305 x 406]

[305 x 406]

[305 x 406]

[305 x 508]

[305 x 406]

[305 x 406]

[609 x 406]

Approx. Shipping Weight

111 [50.3]

117 [53.1]

123 [55.8]

123 [55.8]

148 [67.1]

152 [68.9]

160 [72.6]

(Lbs.) [kg]

 

 

 

 

 

 

 

AFUE

93.5%

92.5%

92.8%

92.0%

93.5%

92.0%

93.5%

California Seasonal

84.68%

86.44%

87.16%

85.16%

85.96%

86.93%

87.57%

Efficiency

 

 

 

 

 

 

 

NOTES: All models are 115V, 60HZ, 1ø. Gas connection size for all models is 1/2" [13 mm] N.P.T.See Conversion Kit Index Form for high altitude derate.

Canadian installations only.

In accordance with D.O.E. test procedures.

MODEL IDENTIFICATION

90

RJ

 

 

04

E

E

S

01

Efficiency

Model

Heating Input

Ignition

Variations

Fuel Code

Rheem

90 = 90 Plus

Designation

BTU/HR [kW]

E = Electric Ignition

Blower Designation [mm]

S = 90 Plus Natural Gas

Value Series

 

 

04

=

45,000 [13]

 

Motor H.P.

 

 

 

 

06

=

60,000 [18]

 

E = Standard Cabinet

 

 

 

 

07

=

75,000 [22]

 

11 x 7 [279 x 178]

 

 

 

 

09

=

90,000 [26]

 

1/2 H.P. – 4 Speed

 

 

 

 

10

= 105,000 [31]

 

F = Standard Cabinet

 

 

 

 

12

= 120,000 [35]

 

12 x 7 [305 x 178]

 

 

 

 

 

 

 

 

3/4 H.P. – 3 Speed

 

 

 

 

 

 

 

 

G = Standard Cabinet

 

 

 

 

 

 

 

 

12 x 11 [305 x 279]

 

 

 

 

 

 

 

 

3/4 H.P. – 3 Speed

 

 

 

 

 

 

 

 

H = Standard Cabinet

 

 

 

 

 

 

 

 

11 x 10 [279 x 254]

 

 

 

 

 

 

 

 

3/4 H.P. – 3 Speed

 

 

 

 

 

 

 

 

J = Standard Cabinet

 

 

[ ] Designates Metric Conversions

 

 

 

12 x 11 [305 x 279]

 

 

 

 

 

1/2 H.P. – 3 Speed

 

 

ICECO 3

Loading...