Professional™ Gas Water Heaters
Available in 38, 40 and 50 Gallon Tall – 40 and 50 Gallon Short Gas Models
!8-Year* Limited Tank and Parts Warranty with a Professional Installation.
!With ProtectionPlus™ the 8-Year Limited Tank Warranty Becomes 12 Years!
Get
4 MORE YEARS
with ProtectionPlus™
Guardian System™
•One-of-a-kind air/fuel shut-off device offers double protection
•Maintenance free – no filter to clean
•Standard replacement parts
Environmentally Friendly Burner
• Low NOx design for low nitrous oxide emissions
Self-Cleaning
•EverKleen™ patented system fights sediment build-up
•Reduces fuel costs
•Provides more hot water
Easy to Light
• No matches required
Energy Efficient
• More hot water at low operating cost
High Altitude Compliant
•All models are certified for applications up to 6,000 feet above sea level. Some models are certified up to 10,200 feet above sea level. Check factory for listings.
Longer Life
•Patented magnesium anode rod design incorporates a special resistor that protects the tank from rust
Plus…
•Brass drain valve and temperature and pressure relief valve are included
•Meets or exceeds National Appliance Energy Conservation Act (NAECA) requirements
*See Residential Warranty Information Certificate
for complete warranty information.
Energy Factor and Average Annual Operating |
|
|
® |
|
|
|
|
Costs based on D.O.E. (Department of Energy) |
|
|
|
test procedures. D.O.E. national average fuel rate |
|
|
|
|
|
|
|
natural gas $1.218/therm; LP $1.87/gallon. |
|
|
|
|
|
DESCRIPTION |
|
|
FEATURES |
|
|
ROUGHING IN DIMENSIONS (SHOWN IN INCHES) |
|
|
ENERGY INFO. |
||||||||||
T |
|
|
|
|
|
|
|
|
|
|
|
|
HT. TO |
|
WATER |
HT. TO |
|
|
|
|
|
|
|
|
GAS INPUT IN |
|
RECOVERY IN |
FIRST HOUR |
HT. TO |
TANK |
|
GAS |
VENT |
CONN. |
SIDE |
WATER |
SHIP. |
ENERGY |
AVG. ANN. |
||||
Y |
GAL. |
|
|
|
DIAM. |
||||||||||||||||
P |
|
|
THOUS. BTU/HR. |
|
G.P.H. 90° RISE |
DEL. G.P.H. |
VENT |
HT. |
CONN. |
SIZE |
CNTR. |
T&P |
CONN. |
WT. |
FACTOR |
OPER. COST |
|||||
E |
CAP. |
|
MODEL NUMBER |
NAT. |
LP |
|
NAT. |
LP |
NAT. |
A |
B |
C |
D |
E |
F |
G |
|
H |
(LBS) |
NAT. |
NAT. |
|
40 |
|
22V40 PROF |
38 |
32 |
|
38.4 |
32.3 |
73 |
61-3/4 |
58-3/8 |
18-1/8 |
14-1/2 |
3 |
8 |
52-1/4 |
|
3/4 |
120 |
0.59 |
$309 |
|
38 |
|
42V40 PROF |
40 |
34 |
|
40.4 |
34.3 |
68 |
61-1/2 |
57-3/4 |
19-3/4 |
14-1/2 |
3 |
8 |
52-1/4 |
|
3/4 |
125 |
0.60 |
$304 |
T |
40 |
|
RHG PRO40-40F |
40 |
34 |
|
40.4 |
34.3 |
68 |
63-1/4 |
59-3/4 |
21 |
14-1/2 |
3 |
8 |
53-1/2 |
|
3/4 |
135 |
0.62 |
$294 |
A |
50 |
|
22V50 PROF |
38 |
36 |
|
38.4 |
36.4 |
90 |
61-1/2 |
58-1/4 |
20-1/8 |
14-1/2 |
3 |
8 |
51-3/8 |
|
3/4 |
130 |
0.58 |
$315 |
L |
|
|
|
||||||||||||||||||
L |
50 |
|
42V50-40 PROF |
40 |
36 |
|
40.4 |
36.4 |
83 |
61-1/2 |
58 |
21-3/4 |
14-1/2 |
3 |
8 |
52-1/2 |
|
3/4 |
150 |
0.58 |
$315 |
|
50 |
|
RHG PRO50-40F |
40 |
36 |
|
40.4 |
36.4 |
83 |
62-1/4 |
58-3/4 |
23 |
14-1/2 |
3 |
8 |
52-1/2 |
|
3/4 |
165 |
0.62 |
$294 |
|
50 |
|
RHG PRO50-50F |
50 |
– |
|
50.5 |
– |
83 |
62 |
58 |
21-3/4 |
14-1/2 |
4 |
8 |
52-1/2 |
|
3/4 |
150 |
0.58 |
$315 |
S |
40 |
|
42V40SPROF |
40 |
36 |
|
40.4 |
36.4 |
72 |
53-7/8 |
50-1/2 |
20-1/8 |
14-1/2 |
3 |
8 |
44 |
|
3/4 |
130 |
0.59 |
$309 |
H |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
40 |
|
42VR40SPROF |
40 |
36 |
|
40.4 |
36.4 |
72 |
53-7/8 |
50-1/2 |
23 |
14-1/2 |
3 |
8 |
44 |
|
3/4 |
135 |
0.62 |
$294 |
|
O |
|
|
|
||||||||||||||||||
R |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50 |
|
42V50SPROF |
40 |
36 |
|
40.4 |
36.4 |
84 |
54-1/4 |
49-3/4 |
22-1/4 |
14-1/2 |
3 |
8 |
44 |
|
3/4 |
158 |
0.59 |
$309 |
|
T |
|
|
|
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: RHG PRO40-40PF.
• 40 ng/J NOx Compliant
Rheem Guardian System Features… |
FLUE |
ANODE ROD |
|
H |
H |
|
HOT |
|
|
WATER |
COLD |
|
CONNECTION |
WATER |
|
|
CONNECTION |
|
|
|
|
|
F |
|
|
|
|
|
|
E |
|
Exclusive Combustion |
|
|
|
|
3/4" N.P.T. |
|
|
|
|
|
VALVE |
||
Shut-off System |
Flame Arrestor Plate |
Maintenance Free |
|
RELIEF |
||
|
OPENING |
|||||
Should a spill incident occur, the |
A specially-designed flame arrestor |
Superior air filtration prevents the |
|
|
||
Guardian System shuts off the gas |
prevents ignition of vapors outside |
flame arrestor from becoming |
|
C |
||
supply and the air supply prevent- |
the combustion chamber. |
clogged by lint, dust and oil. |
|
|||
ing a sustained vapor burn in the |
|
|
|
|
|
|
combustion chamber. |
|
Exclusive Professional |
A B |
|
||
exceed ANSI (American National |
|
1/2" |
G |
|||
These units are designed to meet or |
Installation Warranty |
|||||
Standards Institute) requirements and |
D |
|
||||
have been tested according to D.O.E. |
When this Rheem PROFESSIONAL water heater |
|
||||
test procedures and meet or exceed |
is installed by a licensed contractor, the consumer |
|
|
|||
the energy efficiency requirements of |
can upgrade his limited tank and parts warranty |
|
|
|||
NAECA, ASHRAE standard 90, ICC |
from 6 to 8 years by returning to Rheem the |
|
|
|||
Code and all state energy efficiency |
warranty registration card and a copy of the |
|
|
|||
performance criteria for energy |
|
contractor s invoice. |
|
|
|
|
consuming appliances. |
|
This Rheem exclusive warranty upgrade feature |
Y E A R L I M I T E D |
|||
|
|
enhances your value as a plumbing professional. |
||||
Before purchasing this appliance, read |
TANK WARRANTY |
|||||
A professional installation is a better installation. |
||||||
important energy cost and efficiency |
8B E C O M E S12 |
|||||
information available from |
|
Refer to the warranty certificate enclosed with |
||||
your supplier. |
|
each heater for specific details. |
For more details, see form 101-7. |
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U . S . A |
0 3 / 1 0 W P |
F O R M N O . 1 0 1 - 1 4 R e v. 1 2 |