Rudd RGLN-05EAUER Manual

5 (1)
FORM NO. G11-487 REV. 1
Supersedes Form No. G11-487 Rev. 8
GAS FURNACES
CLASSIC SERIES
®
SUPER QUIET 80
80% A.F.U.E.
GAS FURNACES
The Rheem Classic Series
®
Super Quiet 80 line of downflow
gas furnaces is designed for installation in closets, alcoves,
utility rooms, or attics. The design is certified by CSA
International.
Features
Innovative design results in reliable, efficient operation at
sound levels which provide distinct competitive advantage.
Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
Low profile “34 inch” [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
Left or right side gas and electric inlet connections with
quick, simple change.
Direct Spark ignition.
Integrated board with humidifier and electronic air cleaner
hookups.
Insulated blower compartment helps to reduce jacket loss
and noise.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with
Rheem Classic Series
®
Super Quiet 80 gas furnaces are
available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
ISO 9001:2000
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%
RGLN- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
(U.S. & Canadian Models)
2 Rheem Manufacturing Company
STANDARD EQUIPMENT
Completely assembled and wired; induced draft; pressure switch; redundant
main gas control; blower compartment door safety switch; solid state time
on/time off blower control; limit control; manual shut-off valve, pressure
regulator for natural and L.P. (propane) gas; transformer; direct drive multi-
speed blower motor. Furnaces are equipped with cooling/heating relay and
transformer (40VA) ready for air conditioning applications. (Please note: a
thermostat is not included as standard equipment.) Flame sensor diagnostics;
on-board twinning; fused-protection (secondary), 3rd speed option for
continuous fan; common heat/cool terminal.
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our
sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service
dealer to use L.P. (propane) gas without changing burners. Factory approved
kits must be used to convert from natural to L.P. (propane) gas and may be
ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100%
lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
CLASSIC SERIES SUPER QUIET 80
DOWNFLOW GAS FURNACE
Heat Exchanger
Molded
Permanent Filter
Integrated
Furnace
Control
Direct Spark Ignitor
with Remote Sense
In-Shot Burners
Draft Inducer Motor
Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
MODEL NUMBERS
RGLN- SERIES
05EAUER
05NAUER
07EAMER
07NAMER
Standard Filter [mm]
(1) 14 x 20
[356 x 508]
(2) 12 x 20
[305 x 508]
Input–BTU/Hr [kW]
50,000 [15] 75,000 [22]
Heating Capacity BTU/Hr [kW]
41,000 [12] 60,000 [18]
High Altitude Input [kW] 45,000 [13] 67,500 [19.8]
Blower (D x W) [mm]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
Motor H.P. [W]–Speeds [W]–
PSC Type
1
/2-4-PSC
[373]
1
/2-4-PSC
[373]
Motor Full Load Amps 6.8 7.1
Heating Speed MED-LOW MED-HIGH
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
1200
[566]
1200
[566]
Rated E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F
[°C]
25-55
[13.9-30.6]
35-65
[19.5-36.2]
Max. Outlet Air Temp. °F
[°C]
155
[68.3]
165
[73.9]
Approx. Shipping Weight (Lbs.)
[kg]
85
[38.6]
105
[47.6]
High Altitude Output
Capacity [kW]
36,500 [10.7] 53,500 [15.7]
Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029]
07EAMGR
07NAMGR
10EAMER
10NAMER
10EBRJR
10NBRJR
12EARJR
12NARJR
(2) 12 x 20
[305 x 508]
(2) 12 x 20
[305 x 508]
(2) 14 x 20
[356 x 508]
(2) 14 x 20
[356 x 508]
75,000 [22] 100,000 [29.3] 100,000 [29.3] 125,000 [36.6]
54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 [26.1]
60,500 [18] 80,000 [23] 81,000 [24] 99,000 [29]
.12 [.029] .15 [.037] .15 [.037] .20 [.05]
67,500 [19.8] 90,000 [26.4] 90,000 [26.4] 112,500 [33]
11 x 7
[279 x 178]
11 x 7 = 10*AM
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
1
/2-4-PSC
[373]
3
/4-4-PSC
[559]
3
/4-4-PSC
[559]
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-LOW MED-LOW
MED-HIGH HIGH MED-HIGH MED-HIGH
1600
[755]
1200
[566]
2000
[944]
2000
[944]
0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12]
25-55
[13.9-30.6]
45-75 = 10*AM
[25-41.7]
40-70
[22.2-38.9]
40-70
[22.2-38.9]
155
[68.3]
190
[87.8]
170
[76.7]
180
[82.2]
105
[47.6]
115
[52.2]
120
[54.4]
140
[63.5]
15EARJR
15NARJR
(2) 14 x 20
[356 x 508]
150,000 [44]
107,500 [31.5]
120,000 [35]
.20 [.05]
135,000 [39.6]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
9.5
MED-LOW
MED-HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
170
[76.7]
150
[68.0]
80% 80% 80% 80%
AFUE–Electric Ignition Models
80% 80% 80%
NOTES: All models are 115V, 60HZ, 1
Ø
. Gas connection size for all models is
1
/2" N.P.T.
In accordance with D.O.E. test procedures.
See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
MODEL IDENTIFICATIONDOWNFLOW MODELS
[ ] Designates Metric Conversions
RG L N
Furnace
AM E R
Rheem Gas Downflow Design
Series
Variations Blower Heating & Cooling Fuel TypeHeating Input Designation
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
S = 500-1200 CFM
[236-566 L/s]
E = 1100-1330 CFM
[519-628 L/s]
G = 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
07E
NO
x
Model
05N
07N
10N
12N
15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
Electric
Ignition
05E
07E
10E
12E
15E
A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and
Canadian
Standard
Furnace
Loading...