Prince Castle DHB-KFCA Installation Manual

Page 1
OPERATING
540-510revA Printed in USA 2/06 © 2006
INSTRUCTIONS
KFC Holding Bin Model No. DHB-KFCA, DHB-KFCBF
Model DHB-KFC
TABLE OF CONTENTS PAGE
Installation..................................................................... 2
Heater Temperatures.................................................... 2
Overlay Glossary .......................................................... 3
Operation ....................................................................... 4
Programming................................................................. 4
Calibration & Cleaning ................................................. 5
Exploded View & Parts List ........................................ 6
Troubleshooting ............................................................ 7
Wiring Diagram ............................................................. 8
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or workmanship for a period of 1 year from date of original installation, not to exceed 18 months from the date of manufacture.
Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts and labor. This warranty covers on-location service (i.e. trip charges and/or mileage). Travel mileage is limited to 100 miles (200 Kilometers) round trip (one trip warranty) from an authorized service agency or its sub-service agency.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor to be performed during regular work hours. Overtime premium (the incremental amount) will be charged to the customer.
• Damage caused by carelessness, neglect and/or abuse (e.g., dropping, tampering or altering parts, equipment damaged in shipment, by fire, flood or an act of God) is not covered under this warranty.
• All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage is the customer’s responsibility.
• This equipment must be serviced by Prince Castle Authorized Service Agency or a Prince Castle Service Technician during the warranty period.
ELECTRICAL SPECIFICATIONS
DHB-KFCA DHB-KFCBF
Voltage 120 220-240
Watts 1525 2725
Hertz 50/60 50
Amps 12.7 12.3
355 East Kehoe Blvd. ! Carol Stream, IL 60188
Tel: (630) 462-8800 ! Fax: (630) 462-1460
Toll Free: 1-800-PCASTLE
Page 2
INSTALLATION
Printed in USA 2/06 © 2006 540-510revA
1. After you have removed the Holding Bin from the carton, inspect the unit for signs of damage. If there is damage to the unit:
! Notify carrier within 24 hours after delivery.
! Save carton and packing materials for inspection
purposes.
! Contact your local dealer or, if purchased di-
rectly, the Prince Castle Customer Sales Depart­ment at 1-630-462-8800 to arrange for a replace­ment to be sent.
2. Verify that all parts have been received.
figure 1
HEATER IDENTIFICATION
AND PROGRAM SET POINT TEMPERATURES
WITH DOORS
1 REAR
225°F 107°C
1 FRONT
250°F 121°C
2 REAR
180°F
82°C
3 REAR
250°F 121°C
3 FRONT
275°F 134°C
4 REAR
180°F
82°C
3. Remove all packaging and fillers. Note: Make
sure that you remove vinyl protective cover from the stainless steel exterior surfaces and both sides of the doors before turning on power.
4. Remove Heat Shield (packaged and on top of
Bin) and line up 3 Keyhole slots with studs above heater compartment and attach.
5. Plug unit into a 120 Volt grounded outlet.
TEMPERATURE CONTROLLER
The DHB-KFC Holding Bin will hold two 18” x 12” sheet pans. There are top and bottom heaters for each pan. Each heater has independently controlled front and rear sections. All heater zones are inde­pendently controlled to set point temperatures. The following is the relationship between the heater zones and pan location.
Heater 1 Front = Left Upper, Front Heat Zone Heater 1 Rear = Left Upper, Rear Heat Zone Heater 2 Front = Left Lower, Front Heat Zone Heater 2 Rear = Left Lower, Rear Heat Zone Heater 3 Front = Right Upper, Front Heat Zone Heater 3 Rear = Right Upper, Rear Heat Zone Heater 4 Front = Right Lower, Front Heat Zone Heater 4 Rear = Right Lower, Rear Heat Zone
The DHB-KFC has preset temperatures for two different KFC specifications, one for use with doors (Figure 1) and one for use without doors (Figure 2).
IMPORTANT: Do not program a differential greater than 30°F(1.1°C) between the front and rear heater. See the explanation in Troubleshooting on page 7 of this manual.
2 FRONT
180°F
82°C
4 FRONT
180°F
82°C
Original Recipe® Strips
Patties
figure 2
HEATER IDENTIFICATION
AND PROGRAM AND SET POINT TEMPERATURES
WITHOUT DOORS
1 REAR
275°F 134°C
1 FRONT
300°F 148°C
2 FRONT
180°F
82°C
2 REAR
180°F
82°C
4 FRONT
180°F
82°C
3 REAR
330°F 165°C
3 FRONT
360°F 182°C
4 REAR
180°F
82°C
Original Recipe® Strips
Patties
NOTE: Actual heater surface temperatures will vary from programmed set point temperature when front and rear heater set point differential is 20° F(.6°C) or greater.
2
Page 3
OVERLAY PANEL
540-510revA Printed in USA 2/06 © 2006
OVERLAY PANEL BUTTON GLOSSARY
When pressed, will send the unit into the CALIBRATION MODE. When pressed in conjunction with “Change Set Point” Button will allow the set point temperature to be changed.
4
Displays the currently selected heater and zone (Front or Rear)
Displays the actual temperature for the selected heater zone.
2 2 5
In the OPERATION MODE Up and Down Arrows are used for selecting a shelf heater zone for display purposes. In PROGRAM MODE increase/decrease the set point value for the current heater being programmed.
In the OPERATION MODE when pressed, display will show the current temperature for the selected heater zone. In PROGRAM MODE when pressed will end the program mode.
In the OPERATION MODE when pressed, display will show the current setpoint temperature for the selected heater zone. In the PROGRAM MODE when pressed will end the program mode.
When pressed with the PRINCE CASTLE LOGO will allow the setpoint temperature on the selected heater to be changed.
3
Page 4
OPERATION
Printed in USA 2/06 © 2006 540-510revA
1. Turn on power switch and light switch located
under control panel
2. Allow 20 minutes for heaters to reach set point temperatures. For a cold start, the temperature display will show LLL until the heater tempera­ture reaches 75°F(23°C).
NOTE: To set to °F (The unit leaves the factory
set in Celsius) turn the power switch to the “OFF” position. Press and hold the “UP ARROW” Button then turn the power switch to the on position, release the “UP ARROW” 10 seconds after turning on the power. To switch from °F to °C turn power switch to the “OFF” position. Press and hold the “DOWN ARROW” Button then turn the power switch to the on position, release the “DOWN ARROW” 10 seconds after turning on the
power
Show the Setpoint Temperature for a heater:
1. Press the Up or Down Arrow button until the heater number and front or rear heater indicator is selected.
4
2 5 5
2. Press the Set Point button.
PROGRAMMING
L L L
Show the Actual Temperature for a heater:
1. Press the Up or Down Arrow button until the heater number and front or rear heater indicator is selected.
2. Press the Actual Temp button.
1 4 0
Change the Setpoint temperature for a heater:
1. Press the Up or Down Arrow button until the heater number and front or rear Heater indicator are selected.
2. Press and hold the hidden button (PRI) behind the Prince Castle logo and the Change Set Temp button together for 5 seconds. The LED indicator for Change Set point will light.
3
2 5 5
4
3. Use the Up and Down Arrow button to increase or decrease the setpoint temperature. The heater
2 5 0
can be turned off by pressing the Down Arrow until the display reads “OFF”.
IMPORTANT: Do not program a set point tempera­ture differential greater than 30°F(1.1°C) between the front and rear of any heater assembly.
4
Page 5
CALIBRATION
540-510revA Printed in USA 2/06 © 2006
Occasionally, there are measured differences between the restaurant’s temperature meter and what the controller senses for a heater surface temperature. Part of the difference is the location of the controller sensor versus the location where the temperature was measured with the restaurant’s temperature meter. The calibration mode is used to adjust the Prince Castle controller to the restaurant’s meter.
4. Use the Up and Down Arrow button to increase or
decrease the displayed temperature until it matches the value measured by the standalone meter.
5. When the temperature value displayed on the front
panel is equivalent to the temperature value measured by the standalone meter, press the hidden Prince Castle Logo button.
6. The new value will be saved by the controller and
Calibration Mode will end.
IMPORTANT: Allow heaters 20 minutes to stabilize before
starting the calibration mode.
1. Press the Up or Down Arrow button until the heater number and front or rear heater indicator for the heater to be calibrated are selected.
2. Make an external temperature measurement within the shelf cavity near the center of the heater surface using a stand alone temperature meter and probe (not supplied).
Rear Heater Rear Heater
Front Heater Front Heater
Take Temperature Reading At These Spots
CAUTION: Surface temperatures are HOT! Use caution when making any temperature measurements within the heater cavity.
To clear or reset the calibration value, follow steps 1 through 3.
To clear the calibrated offset value, press the Set Point button. The display will show the temperature value the sensing probe is measuring. Use steps 4 through 6 to calibrate the temperature display to the restaurant’s
standalone meter.
CLEANING
CAUTION: This appliance is not water tight. Do not clean with a Water Jet/Jet Spray. Do not immerse appliance in water.
CAUTION: Before unplugging power cord, make sure power switch is in OFF position.
1. Unplug Holding Bin from outlet.
2. Allow unit to cool down. (Approximately 15 minutes.)
3. Press and hold the PRI in the Prince Castle Logo and the Actual Temp button for 3 seconds.The decimal
point to the left of the °F symbol will light indicating
the Calibration Mode. The temperature value displayed on the front panel is the actual heater temperature sensed by the controller.
3. Wipe down with a damp cloth. Do not use a green scotch bright pad, unapproved cleaner, ice
or water.
5
Page 6
EXPLODED VIEW
Printed in USA 2/06 © 2006 540-510revA
540-900S
Door and Hinge Kit
540-128S (110 Volt) 540-224S (220 Volt)
Heater Assembly
540-207
Frame
540-208
Screen
88-639-08
Flourescent Lamp (220 Volt) (Not Shown)
85-080-16
Ballast (220 Volt)
86-203
Light Bulb (110 Volt) (Not Shown)
(Not Shown)
72-280S (110 Volt) 72-349S (220 Volt)
Power Cord
540-206
Heat Guard
540-202
Door
78-166S
Rocker Switch
213-202S
Leg W/Screw (Set of 4)
540-191S
Lamp Socket
540-105S
Overlay & Brkt Assy.
540-235AS
Display Board
540-236AS (110 Volt) 540-232S (220 Volt)
Power Board
6
Page 7
TROUBLESHOOTING
540-510revA Printed in USA 2/06 © 2006
The controller incorporates some diagnostic hardware and software to aid in troubleshooting problems. The display will flash the problem if detected when the heater in question is selected. The error condition will not display in the Change Set Temp mode.
IMPORTANT: To avoid a possible error message, do not program a differential greater than 30°F between
the front and rear of any heater assembly. The heater with the higher setting may not be able to get up to temperature because heat will be flowing to the colder heater. An error message will be displayed and the heater that could not get to temperature will be turned off.
Problem Cause Solution
A. Display flashes Open relay. Replace Power Circuit Board “Opn” & “rEL” Circuit inoperable
B. Display flashes Shorted relay. Replace Power Circuit Board. “SHr” & “rEL” Circuit inoperable.
Open heater. Test heater resistance.150.2 Ohms
Unplugged ribbon cable between
Verify ribbon cable connection. Power and Main Circuit Boards.
C. Display shows “LLL” Temperature is below 75° F N/A
(normal operation)
Display shows “LLL” Heater inoperable. Test heater resistance.150.2 Ohms for an extended period Probe inoperable. Check for open thermocouple wires from of time. probe. Replace heater/probe assembly.
Display shows “LLL” and Circuit inoperable. (see A). See A above. then changes to “Opn”& “rel” and heater surface temperature is cool.
Display shows “LLL” and Circuit inoperable. (see B) See B above. then changes to “SHr”&“rEL” and heater surface temperature is cool.
D.Display shows “HHH” for Temperature is above400° F Diagnostic circuit inoperable. Replace an extended period of time (abnormal operation) Power Circuit Board.See B above. and heater surface
temperature is hot.
Display shows “HHH” for Probe is inoperable Check for pinched thermocouple
an extended period of time wires from probe. Replace heater/probe and heater surface assembly. temperature is cool.
7
Page 8
WIRING DIAGRAM (DHB-KFC)
Printed in USA 2/06 © 2006 540-510revA
8