E-STOP relay, safety gate monitor
Up to Category 4, EN 954-1
PNOZ 16SP
Safety relay for monitoring emergency
stop pushbuttons, safety gates, safety
mats and safe edges
Approvals
PNOZ 16SP
Unit features
` Positive-guided relay outputs:
– 2 safety contacts (N/O), instanta-
neous
` 2 semiconductor outputs
` Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Reset button
– Safe edges
– Safety mats
` LED indicator for:
– Switch status channel 1/2
– Supply voltage
– Detection of shorts across con-
tacts on safety mat "EXT.
FAULT"
` Semiconductor outputs signal:
– Switch status channel 1/2
– Detection of shorts across con-
tacts "EXT. FAULT"
Unit description
The safety relay meets the requirements of EN 60204-1, IEC 60204-1,
EN 1760-1 and EN 1760-2 and may be
used in applications with
` E-STOP pushbuttons
` Safety gates
` Safety mats
` Safe edges
The safety relay is not suitable for noncontact barriers because
` a dynamic start is not possible
` the unit can be started during the
delay-on de-energisation time.
Safety features
The relay conforms to the following
safety criteria:
` The circuit is redundant with built-in
self-monitoring.
` The safety function remains effecti-
ve in the case of a component failure.
` The correct opening and closing of
the safety function relays is tested
automatically in each on-off cycle.
` The tranformer is short circuit-
proof. An electronic fuse is used on
a DC supply.
Block diagram
B1 B2 13 23
=
Power
A1 A2
S11 S12 S21 S22
Feed-
back
~
Y1 Y2
S31 S32
InputInput
0 V 24 V
Y30 Y31 Y32 Y35
Input
S33 S34
Reset/
Start
K1
K2
14 24
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-162-2010-06
E-STOP relay, safety gate monitor
Up to Category 4, EN 954-1
PNOZ 16SP
Function description
` Single-channel operation: no red-
undancy in the input circuit, earth
faults in the reset and input circuit
are detected.
` Dual-channel operation with detec-
tion of shorts across contacts: redundant input circuit, detects
– earth faults in the reset and input
circuit,
Timing diagram
POWER
Reset/Start
Input
Output safe
FAULT
Semi FAULT
Semi CH
t1 t2
t1 t2
– short circuits and shorts bet-
ween contacts in the input circuit.
` When the safety mat is actuated, a
short is formed between the inputs
and internal fault detection is energised. The safety contacts open
and the LED EXT.FAULT is lit. If the
safety mat is cleared and supply
voltage is maintained, the unit is
1
t
1
t2 t3
ready for operation again once the
recovery time has elapsed.
` Automatic start: Unit is active once
the input circuit has been closed.
` Manual reset: Unit is active once
the input circuit is closed and then
the reset circuit is closed.
` Increase in the number of available
contacts by connecting contact expander modules or external contactors/relays.
ab
t1
2
t1
t2
t2
t1
t2
Key
` Power: Supply voltage
` Reset/start: Reset circuit S33-S34
` Input: Input circuits S11-S12, S21-
S22, S31-S32
` Output safe: Safety contacts 13-14,
23-24
` Out semi FAULT: Semiconductor
output supply voltage Y35
Wiring
Please note:
` Information given in the “Technical
details” must be followed.
` Outputs 13-14, 23-24 are safety
contacts.
` To prevent contact welding, a fuse
should be connected before the
output contacts (see technical details).
` Calculation of the max. cable runs
in the input circuit:
l
max
R
lmax
=
I
max
Rl / km
R
= max. overall cable resi-
lmax
stance (see technical details)
` Out semi CH: Semiconductor out-
put switch status Y32
` FAULT: Short between contacts in
the input circuit due to actuation of
safety mat
` c: Automatic reset
` d: Manual reset
/km = cable resistance/km
R
l
` Use copper wire that can withstand
60/75 °C.
` Sufficient fuse protection must be
provided on all output contacts with
capacitive and inductive loads.
` a: Input circuit closes before reset
circuit
` b: Reset circuit closes before input
circuit
: Switch-on delay
` t
1
` t2: Delay-on de-energisation
: Recovery time after short across
` t
3
contacts
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-162-2010-06Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-2
E-STOP relay, safety gate monitor
Up to Category 4, EN 954-1
PNOZ 16SP
Preparing for operation
` Supply voltage
Supply voltage AC DC
A1
A2
B2 PE
L1
N
` Input circuit
Input circuit Single-channel Dual-channel
E-STOP
without detection of shorts across
contacts
S21
S22
S12
S11
S32
S31
S1
E-STOP
with detection of shorts across contacts
S11
S12
Safety gate
without detection of shorts across
contacts
S21
S22
S12
S11
S32
S31
S1
B1
B2
S22
S32
S31
S21
L+
L-
S1
Safety gate
with detection of shorts across contacts
Safety mat, safe edge
with detection of shorts across contacts
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
S11
S12
S11
S12
S22
S21
S32
S31
S1
S2
S22
S21
S32
S31
NSG-D-2-162-2010-06