Partlow 1160+, 1400+ Operating Manual

4.6 (5)
Partlow 1160+, 1400+ Operating Manual

1/16 - 1/8 - 1/4 DIN PROCESS CONTROLLERS

CONCISE PRODUCT MANUAL (59300-4)

CAUTION: Installation should be only performed by technically competent personnel. Local Regulations regarding electrical installation & safety must be observed.

1. INSTALLATION

The models covered by this manual have three different DIN case sizes (refer to section 10). Some installation details vary between models. These differences have been clearly shown.

Note: The functions described in sections 2 thru 9 are common to all models.

Installing Option Modules

1/16 Din Size Instruments

CPU PCB

Mounting Struts
Option Module 1
Option Module A
Option Module 2
Option Module 3

 

 

PSU PCB

 

1/8 & 1/4 Din Size Instruments

CPU PCB

Mounting Struts
Option Module B
Option Module A

 

Option Module 2
Option Module 3

 

Option Module 1

PSU PCB

 

To access modules 1, A or B, first detach the PSU and CPU boards from the front by lifting first the upper, and then lower mounting struts. Gently separate the boards.

a.Plug the required option modules into the correct connectors, as shown below.

b.Locate the module tongues in the corresponding slot on the opposite board.

c.Hold the main boards together while relocating back on the mounting struts.

d.Replace the instrument by aligning the CPU and PSU boards with their guides in the housing, then slowly push the instrument back into position.

Note: Option modules are automatically detected at power up.

Option Module Connectors

1/16 Din Size Instruments

Option Slot 1

Option Slot A

Connectors

Connectors

PL7 & PL8

PL5 & PL6

Option Slot 2

Option Slot 3

Connector

Connector

PL4A

PL4B

 

1/8 & 1/4 Din Size Instruments

Option Slot B

Connectors

PL2A, PL2B &

PL2C

Option Slot 2

Connector

PL4A

Option Slot 1

Connectors

PL7 & PL8

Option Slot A

Connectors

PL5 & PL6

Option Slot 3

Connector

PL4B

Panel-Mounting

The mounting panel must be rigid, and may be up to 6.0mm (0.25inch) thick. Cut-out sizes are:

Cut-Out Dim A

Cut-Out Dim B

1/16 & 1/8 Din = 45mm

1/16

Din = 45mm

1/4 Din = 92mm

1/8 &

1/4 Din = 92mm

For n multiple instruments mounted side-by-side, cut-out A is 48n-4mm (1/16 & 1/8 Din) or 96n-4mm (1/4 Din)

Mounting Panel

Instrument

Housing

Ratchets

B

A

Tolerance +0.5, -0.0mm

Slide mounting clamp over the instrument housing towards rear face of mounting panel until the tongues engage in ratchets and instrument is clamped in position.

Gasket

Hold instrument firmly in

 

position (apply pressure

 

to bezel only)

CAUTION: Do not remove the panel gasket; it is a seal against dust and moisture.

Rear Terminal Wiring

USE COPPER CONDUCTORS (EXCEPT FOR T/C INPUT)

Single Strand wire gauge: Max 1.2mm (18SWG)

1/16 Din Size Instruments

1/8 & 1/4 Din Size Instruments

These diagrams show all possible option combinations. The actual connections required depends on the exact model and options fitted.

CAUTION: Check information label on housing for correct operating voltage before connecting supply to Power Input

Fuse: 100 – 240V ac – 1amp anti-surge 24/48V ac/dc – 315mA anti-surge

Note: At first power-up the message # / 3 C" is displayed, as described in section 7 of this manual. Access to other menus is denied until configuration mode is completed

2. SELECT MODE

Select mode is used to access the configuration and operation menu functions.

It can be accessed at any time by holding down

and pressing

.

In select mode, press

or

to choose the required mode, press

to enter.

An unlock code is required to prevent unauthorised entry to Configuration, & Setup

modes. Press

or

to enter the unlock code, then press

to proceed.

 

 

 

 

 

 

Mode

Upper

Lower

Description

 

Default

 

Display

Display

 

 

Unlock

 

 

 

 

 

Codes

Operator

@/+

-'3/

Normal operation

 

None

Set Up

-!/@

-'3/

Tailor settings to the application

 

Configuration

3 C"

-'3/

Configure the instrument for use

 

Product Info

C"

-'3/

Check manufacturing information

None

Auto-Tuning

/1C

-'3/

Invoke Pre-Tune or Self-Tune

 

Note: The instrument will always return automatically to Operator mode if there is no key activity for 2 minutes.

3. CONFIGURATION MODE

First select Configuration mode from Select mode (refer to section 2).

Press to scroll through the parameters, then press or to set the required value. Press to accept the change, otherwise parameter will revert to previous value. To exit from Configuration mode, hold down and press , to return to Select mode.

Note: Parameters displayed depends on how instrument has been configured. Refer to user guide (available from your supplier) for further details. Parameters marked * are repeated in Setup Mode.

 

 

Parameter

 

Lower

Upper

Adjustment range & Description

 

Default

 

 

 

 

 

 

Display

Display

 

 

 

 

 

Value

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C)/

See following table for possible codes

 

63

 

 

 

Range/Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Input Type &

Code

 

 

 

 

 

 

 

Code

Input Type &

Input Type &

 

 

 

 

 

Range

 

 

Range

 

Range

 

 

 

 

bC

B: 100 - 1824 ºC

L.C

L: 0.0 - 537.7 ºC

P24F

PtRh20% vs 40%:

 

 

 

bF

B: 211 - 3315 ºF

L.F

L: 32.0 - 999.9 ºF

32 - 3362 ºF

 

 

 

 

 

 

 

 

 

 

 

 

CC

C: 0 - 2320 ºC

NC

N: 0 - 1399 ºC

PTC

Pt100: –199 - 800 ºC

 

 

 

 

 

 

 

 

 

 

 

 

CF

C: 32 - 4208 ºF

NF

N: 32 - 2551 ºF

PtF

Pt100: –328 - 1472 ºF

 

 

 

 

 

 

 

 

 

 

 

 

JC

J: –200 - 1200 ºC

rC

R: 0 - 1759 ºC

Pt.C

Pt100: –128.8 - 537.7 ºC

 

 

 

JF

J: –328 - 2192 ºF

rF

R: 32 - 3198 ºF

Pt.F

Pt100: –199.9 - 999.9 ºF

 

 

 

j.C

J: –128.8 - 537.7 ºC

SC

S: 0 - 1762 ºC

:

0

- 20 mA DC

 

 

 

 

j.F

J: –199.9 - 999.9 ºF

SF

S: 32 - 3204 ºF

:

4

- 20 mA DC

 

 

 

 

KC

K: –240 - 1373 ºC

tC

T: –240 - 400 ºC

:

0

- 50 mV DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KF

K: –400 - 2503 ºF

tF

T: –400 - 752 ºF

.

10 - 50 mV DC

 

 

 

 

k.C

K: –128.8 - 537.7 ºC

t.C

T: –128.8 - 400.0 ºC

:

0

- 5 V DC

 

 

 

 

K.F

K: –199.9 - 999.9 ºF

t.F

T: –199.9 - 752.0 ºF

:

1

- 5 V DC

 

 

 

 

LC

L: 0 - 762 ºC

P24C

PtRh20% vs. 40%:

:

0

- 10 V DC

 

 

 

 

LF

L: 32 - 1403 ºF

0 - 1850 ºC

:

2

- 10 V DC

 

 

 

 

 

 

 

 

Note: Decimal point shown in table indicates temperature resolution of 0.1°

Parameter

Lower

Upper

 

Adjustment range & Description

Default

 

Display

Display

 

Value

Scale Range

+1'

 

Scale Range Lower Limit +100

Range max

Upper Limit

 

 

to Range Maximum

(Lin=1000)

 

 

 

Scale Range

+''

 

 

Range Minimum to

Range min

Lower Limit

 

Scale Range Upper Limit -100

(Linear=0)

 

 

Decimal point

=) -

0=XXXX, 1=XXX.X, 2=XX.XX, 3=X.XXX

1

position

(non-temperature ranges only)

 

 

Control Type

3.4)

-C#'

 

Primary only

-C#'

=1 '

 

Primary & Secondary

 

 

 

 

 

 

(e.g. heat & cool)

 

Primary Output

3.*'

+!1

 

Reverse Acting

+!1

Control Action

= +

 

Direct Acting

 

 

 

 

 

):$

 

Process High Alarm

 

 

 

):'

 

Process Low Alarm

 

Alarm 1Type

'

=

 

Deviation Alarm

):$

 

 

C=

 

Band Alarm

 

 

 

C C

 

No alarm

 

High Alarm 1

)?

 

 

 

Range Max

value*

Range Minimum to Range Maximum in

 

 

Low Alarm 1

)'

 

 

display units

Range Min

value*

 

 

 

 

 

 

 

 

Band Alarm 1

'

1 LSD to span from setpoint in display units

 

value*

 

 

 

 

 

Dev. Alarm 1

= '

+/- Span from setpoint in display units

 

value*

 

 

 

 

 

Alarm 1

$4

1 LSD to full span in display units

 

Hysteresis*

 

 

 

 

 

Alarm 2 Type*

'

 

 

 

):'

High Alarm 2

)?

 

 

 

Range Max

value*

 

 

 

 

 

 

Options as for alarm 1

 

Low Alarm 2

)'

 

 

Range Min

value*

 

 

 

 

 

 

 

 

Band Alarm 2

'

 

 

 

 

value*

 

 

 

 

 

 

 

 

Parameter

Lower

Upper

 

Adjustment range & Description

Default

 

Display

Display

 

Value

Dev. Alarm 2

= '

 

 

 

 

Value*

 

 

Options as for alarm 1

 

 

 

 

Alarm 2

$4

 

 

 

 

 

 

Hysteresis*

 

 

 

 

 

 

 

 

Loop Alarm

' C

= - (disabled) or C (enabled)

= ,

Loop Alarm

' .

 

 

1 sec to 99 mins. 59secs

.

Time*

 

 

 

 

 

 

 

 

 

C C!

 

No alarms Inhibited

 

Alarm Inhibit

%C?

'

 

Alarm 1 inhibited

C C!

'

 

Alarm 2 inhibited

 

 

 

 

 

 

/?

 

Alarm 1 and alarm 2 inhibited

 

 

 

)+

 

Primary Power

 

 

 

-!N

 

Secondary Power

 

 

 

7:=

 

Alarm 1, Direct

 

 

 

:+

 

Alarm 1, Reverse

 

 

 

:=

 

Alarm 2, Direct

 

 

 

:+

 

Alarm 2, Reverse

 

Output 1 Usage

0-

'):=

 

Loop Alarm, Direct

)+

'):+

 

Loop Alarm, Reverse

 

 

 

 

 

 

+:=

 

Logical Alarm 1 OR 2, Direct

 

 

 

+:+

 

Logical Alarm 1 OR 2, Reverse

 

 

 

=:=

 

Logical Alarm 1 AND 2, Direct

 

 

 

=:+

 

Logical Alarm 1 AND 2, Reverse

 

 

 

+!/-

 

Retransmit SP Output

 

 

 

+!/)

 

Retransmit PV Output

 

 

 

:

 

0 to 5 V DC output

 

Linear Output 1

 

:

 

0 to 10 V DC output

 

/4)

:

 

2 to 10 V DC output

:

Range

 

 

 

 

 

 

:

 

0 to 20 mA DC output

 

 

 

 

 

 

 

:

 

4 to 20 mA DC output

 

Retransmit

+ $

 

 

-1999 to 9999

 

Output 1 Scale

 

(display value at which output

Range max

maximum

 

 

 

will be maximum)

 

Retransmit

+ '

 

 

-1999 to 9999

 

Output 1 Scale

 

(display value at which output

Range min

minimum

 

 

 

will be minimum)

 

Output 2 Usage

0-

 

 

As for output 1

Sec or Al2

Linear Output 2

/4)

 

 

As for output 1

:

Range

 

 

 

 

 

Retransmit

+ $

 

 

-1999 to 9999

 

Output 2 Scale

 

(display value at which output

Range max

maximum

 

 

 

will be maximum)

 

Retransmit

+ '

 

 

-1999 to 9999

 

Output 2 Scale

 

(display value at which output

Range min

minimum

 

 

 

will be minimum)

 

Output 3 Usage

0-

 

 

As for output 1

7:=

Linear Output 3

/4)

 

 

As for output 1

:

Range

 

 

 

 

 

Retransmit

+ $

 

 

-1999 to 9999

 

Output 3 Scale

 

(display value at which output

Range max

maximum

 

 

 

will be maximum)

 

Retransmit

+ '

 

 

-1999 to 9999

 

Output 3 Scale

 

(display value at which output

Range min

minimum

 

 

 

will be minimum)

 

Display Strategy

= ,@

, , , , or (refer to section 8)

 

Serial

 

-3%

 

ASCII

 

)+ /

Mm C

 

Modbus with no parity

Mm C

Communications

 

Mm

 

Modbus with Even Parity

Protocol

 

 

 

 

 

Mm

 

Modbus with Odd Parity

 

Serial

 

.

 

1.2 kbps

 

 

.

 

2.4 kbps

 

Communications

 

 

 

 

.

1=

.

 

4.8 kbps

Bit Rate

 

 

 

 

 

 

.

 

9.6 kbps

 

 

 

 

 

 

 

.

 

19.2 kbps

 

Comms Address

==+

 

 

1 to 255 (Modbus), 1 to 99 (ASCII)

 

Comms Write

3 C

+:Ww

 

Read/Write

+:Ww

+:

 

Read only

 

 

 

 

Digital Input 1

= #

= -

 

Setpoint 1 / Setpoint 2 select*

= -

Usage

 

= ,

 

Automatic / Manual select

 

Digital Input 2

 

= -

 

Setpoint 1 / Setpoint 2 select*

 

= #

= ,

 

Automatic / Manual select

= +-

Usage

 

 

 

= +,

 

Remote / Local setpoint select

 

Note: = # has priority over = # if both are configured for the same usage. If = # or = # == - the remote setpoint input is disabled.

Continued on next page…