OLYMPUS C-40 Zoom TECHNICAL INFORMATION TID C40Z E003 R OE

TECHNICAL INFORMATION
NO. TID-C40Z-E003-R_OE
DATE: June 6th 2002
Page 1 of 2
SUBJECT: Special Note For Assembling And Disassembling Of
C-40ZOOM / D-40ZOOM
Product name: C-40Zoom / D-40Zoom
If the CA-2 is damaged, the camera does not operate anymore. (LED blinks and the lens does not operate). Please find below the most critical points.
Reason: The CA-2 board is a multi layer PCB, which can easily be damaged by bending, pressing and
twisting of it.
Point 1: The CA-2 may be damaged, if it will be pressed too strongly when assembling it. Countermeasure: Open the hook beforehand and assemble the CA-2.
Point 2: The CA-2 may be damaged, if the it will be pressed too strongly when the inlay is assembled to
cabinet front.
Countermeasure: Press only at the mentioned points when assembling it.
Press only at these points.
DO NOT PRESS CA-2 PCB !
OLYMPUS OPTICAL CO. (EUROPA) GMBH
TECHNICAL INFORMATION
NO. TID-C40Z-E003-R_OE
DATE: June 6th 2002
Page 2 of 2
Point 3: The CA-2 may be damaged by the pressure and distortion of the PCB when putting the screws
on the CA-2 or PW-1.
Countermeasure: Do not make pressure and distortion to the PCB, when putting the screws on them.
Do not press strongly on the PW-1, if CA-2 is already assembled.
OLYMPUS OPTICAL CO. (EUROPA) GMBH
Loading...