OLYMPUS C-360 Zoom DISASSEMBLY AND ASSEMBLY PROCEDURE

B. DISASSEMBLY AND ASSEMBLY PROCEDURE X-350/D-575ZOOM/C-360ZOOM
B. DISASSEMBLY AND ASSEMBLY
PROCEDURE
[1] REMOVAL OF CABINET BACK, LCD, CABINET FRONT AND TB1 BOARD.......B-2
[2] REMOVAL OF TB2 BOARD AND CP1 BOARD......................................................B-3
[3] REMOVAL OF LENS UNIT AND ST1 BOARD........................................................B-3
[4] ASSEMBLY OF LENS UNIT AND VIEWFINDER ...................................................B-4
B-1 Ver.1
B. DISASSEMBLY AND ASSEMBLY PROCEDURE X-350/D-575ZOOM/C-360ZOOM
[1] REMOVAL OF CABINET BACK, LCD, CABINET FRONT AND TB1 BOARD
Disassembly perform as follows and assembly perform by reversing the disassembly steps.
Be sure to discharge the main capacitor, then continue to disassembling.
! Beware of electric shock
Danger of electric shock. Use a discharging tool to remove the electrical charge before working.
1. Open the cover DC.
2. Open the cover card
3. Seven screws 1.7 x 4
4. Cabinet back
5. FPC
6. Discharge
7. Connector
8. FPC
9. LCD
10. Two screws 1.7 x 5
6
The lead free solder is applied to this product.
!
11. Holder monitor
12. Two screws 1.7 x 5
13. Cover jack
14. Stand
15. Connector
16. Cabinet front
17. Three screws 1.7 x 4
18. TB1 board
19. Shield button
Use the lead free solder in working.
Notice
1
3
2
19
10
C
18
B
17
12
15
5
A
8
7
4
9
11
C
A
B
13
3
14
16
3
B-2 Ver. 1