SUBJECT
Version-up of Firmware (1)
2004.July.07
Change of Firmware for C-160/D-395
a) As rotate a shot image +90 degrees and edit it in black and white/sepia,an image that is rotated -90
degrees appears for a moment right after the creation.
b) Set the image quality mode to SQ2 and playback the image after shooting in 2-in-1 picture mode,
then far-right portion of the LCD has a faulty display.
Refer to the D-3 of Service Manual
Change classification
>Running change
E-2 Ver.1
Page 3
C-160/D-395
E. NOTICE OF MODIFICATION
SUBJECT Version-up of Firmware (2)
Change of firmware for C-160/D-395
For all destination :
Countermeasure of following items for C-160/D-395.
1) Parameter of printing cannot be changed when the C-160/D-395 and the Hewlett-Packard’s
printer are connected by Pict Bridge function.
2004.Dec.03
2) The error code “CARD FULL” is not indicated when both the folder and file numbers reach
their maximum(999/9999).
3) The xD Picture card can not be formatted on C-160/D-395 when the property of DCIM folder
in the xD Picture card is set to “read-only” by PC.
Refer to D-3 of Service manual about updating procedure.
Update the firmware to all the returned cameras from the market .