OLYMPUS C-100 Adjustment Method

C. ADJUSTMENT METHOD C-100/D-370
C. ADJUSTMENT METHOD
[1] TABLE FOR SERVICING TOOLS .......................................................................... C-2
[2] EQUIPMENT ..........................................................................................................C-2
[3] ADJUSTMENT ITEMS AND ORDER ..................................................................... C-2
[4] SETUP....................................................................................................................C-2
[5] CONNECTING THE CAMERA TO THE COMPUTER ............................................ C-3
[7] ADJUST SPECIFICATIONS ................................................................................... C-4
1. 5.1 V (A) VOLTAGE ADJUSTMENT ................................................................... C-4
2. AWB ADJUSTMENT ........................................................................................... C-5
3. COLOR ADJUSTMENT ......................................................................................C-5
4. CCD DEFECT DETECT ADJUSTMENT ............................................................ C-5
5. CCD BLACK POINT AND WHITE POINT DEFECT DETECT ADJUSTMENT ..C-5
6. LCD PANEL ADJUSTMENT..............................................................................C-6
6-1. LCD H AFC ADJUSTMENT .......................................................................C-6
6-2. LCD RGB OFFSET ADJUSTMENT ........................................................... C-6
6-3. LCD GAIN ADJUSTMENT ........................................................................C-6
6-4. LCD RED BRIGHTNESS ADJUSTMENT ................................................. C-6
6-5. LCD BLUE BRIGHTNESS ADJUSTMENT ...............................................C-7
7. LENS ADJUSTMENT ..........................................................................................C-7
[8] ADJUSTMENT ITEMS ............................................................................................C-8
SIMENS STAR CHART ................................................................................................... C-9
C-1 Ver.1/Rev.1
C. ADJUSTMENT METHOD C-100/D-370
[1] Table for Servicing Tools
Ref. No. Name Part code
J-1
Color viewer 5,100 K
Siemens star chart
J-2
Calibration software
J-3
Chart for color adjustment
J-4
LH Plate2 1 VE383000 Large Siemens star chart
Note: J-1 color viewer is 100 - 110 VAC only.
Number
1
1
1
1
1
VJ8-0007
VJ8-0179
VJ8-0155
KC0324
J-1 J-2
J-3
J-4
[2] Equipment
1. Oscilloscope
2. Digital voltmeter
3. AC adaptor
4. PC (IBM R -compatible PC, Pentium processor, Window 98 or Me)
[3] Adjustment Items and Order
1. 5.1 V (A) Voltage Adjustment
2. AWB Adjustment
3. Color Adjustment
4. CCD Defect Detect Adjustment
5. CCD Black Point and White Point Defect Detect Adjust­ment
6. LCD Panel Adjustment
6-1. LCD H AFC Adjustment 6-2. LCD RGB Offset Adjustment 6-3. LCD Gain Adjustment 6-4. LCD Red Brightness Adjustment 6-5. LCD Blue Brightness Adjustment
7. LENS Adjustment
Note:
1. If the lens, CCD, board and changing the part in item 2-
5 replace, it is necessary to adjust again. 2-3 adjust­ ments other than these should be carried out in se­ quence. Item 4 and 5 adjustments should be carried out after item 2.
[4]. Setup
1. System requirements
Windows 98 or Me IBM R -compatible PC with pentium processor CD-ROM drive
3.5-inch high-density diskette drive USB port 40 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your diskette drive.
2. Open Explorer.
3. Copy the DscCalDI_127 folder on the floppy disk in the FD drive to a folder on the hard disk.
3. Installing USB drive
Install the USB drive with camera or connection kit for PC.
C-2 Ver. 1/Rev.1
C. ADJUSTMENT METHODC-100/D-370
[5] Connecting the camera to the computer
1. Line up the arrow on the cable connector with the notch on the camera's USB port. Insert the connector.
2. Locate a USB port on the back of your computer.
USB cable
To USB port
AC adaptor
C-3Ver. 1
C. ADJUSTMENT METHOD C-100/D-370
[6] USB Storage Information Registration
USB storage data is important for when the camera is con­nected to a computer via a USB connection. If there are any errors in the USB storage data, or if it has not been saved, the USB specification conditions will not be satisfied, so always check and save the USB storage data.
Preparation:
POWER switch: ON
Adjustment method:
1. Connect the camera to a computer. (Refer to [5] Con­necting the camera to the computer on the page C-3.)
2. Double-click on the DscCalDi127.
3. Click on the Get button in the USB storage window and check the USB storage data. VID: OLYMPUS PID: C-100/D-370 Serial: Rev. : 1.00
4. Check the ”Serial” in the above USB storage data. If the displayed value is different from the serial number printed on the base of the camera, enter the number on the base of the camera. Then click the Set button.
5. Next, check VID, PID and Rev. entries in the USB stor­age data. If any of them are different from the values in
3. above, make the changes and then click the corre­sponding Set button.
Calibration
AWB
Focus
UV Matrix
Cal Mode
Cal Data
USB strage
VID
Get
PID
Set
OK
OK
Upload
Firmware
Image
Initialize
EVF
LCD Type
LCD
R Bright
RGB Offset
Tint
H AFC Test
Serial
Set
Set
Rev.
B Bright
Gain
Phase
Set Set
VCOMDC
VCOMPP
Setting
Language
Video Mode
[7] Adjust Specifications
[CP1 board (Side A/B)]
S3001
CL528
Side A
CL365
CL364
VR502
CL411
CL412
Side B
Note:
1. Voltage adjustment is necessary to repair in the ST1 board and replace the parts.
Preparation:
1. Shorten the pin 1 and pin 2 of S3001 (card switch).
2. Shorten the CL364 and CL365 (connection parts of power switch wires).
3. Insert the smart media.
4. Connect the power, and turn on the LCD switch.
CL410
1. 5.1 V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR502 to 5.10 ± 0.05 V.
CL528
Digital voltmeter
VR502
5.10
± 0.05 V
C-4 Ver. 1/Rev.1
C. ADJUSTMENT METHODC-100/D-370
2. AWB Adjustment
Camera
All white pattern
Color viewer (5,100K)
Preparation:
POWER switch: ON Macro mode: OFF
Adjusting method:
1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer ex­cept the white section. (Do not enter any light.)
2. Double-click on the DscCalDi127.
3. Click the ”AWB”, and click the ”Yes”.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Adjustment method:
1. Set the color adjustment chart to the color viewer. (Do not enter any light.)
2. Set the color adjustment chart so that it becomes center of the screen.
3. Double-click on the DscCalDi127.
4. Click the ”UV Matrix”, and Click the ”Yes”.
5. Adjustment values will appear on the screen.
6. Click the OK.
4. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi127.
2. Select ”CCD Defect” on the LCD ”Test”, and click the
”Yes”.
3. After the adjustment is completed, the number of defect will appear.
5. CCD Black Point And White Point Defect Detect
Adjustment
3. Color Adjustment
Camera
Preparation:
POWER switch: ON Macro mode: OFF
15 cm ± 1 cm
All white pattern color
viewer (5,100K) and
color matrix adjustment chart
Camera
All white pattern
Color viewer (5,100K)
Preparation:
POWER switch: ON Macro mode: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer ex­cept the white section. (Do not enter any light.)
2. Double-click on the DscCalDi127.
3. Select ”CCD Black” on the LCD “Test”, and click the
“Yes”.
4. After the adjustment is completed, the number of defect will appear.
C-5Ver. 1
6. LCD Panel Adjustment
[CP1 board (Side A/B)]
C. ADJUSTMENT METHOD C-100/D-370
S3001
CL412
Side A
CL411
Side B
VR502
CL365 CL364
CL410
CL528
3.8 V ±
0.1 Vp-p
CL410 waveform
6-3. LCD Gain Adjustment
Adjusting method:
1. Adjust LCD “Gain” so that the amplitude of the CL410 waveform is 7.2 V ± 0.2 Vp-p.
Note:
6-2. LCD RGB Offset adjustment should always be carried out first.
7.2 V ±
0.2 Vp-p
6-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi127.
2. Select 0 on the LCD “H AFC”.
3. While watching the LCD monitor, adjust “H AFC” so that the edge of the LCD adjustment frame are the same dis­tance from the left and right edge of the LCD screen. (A = B)
LCD
LCD screen
A
adjustment
B
frame
FPC
6-2. LCD RGB Offset Adjustment
Adjusting method:
1. Adjust LCD “RGB Offset” so that the amplitude of the CL410 waveform is 3.8 V ± 0.1 Vp-p.
CL410 waveform
6-4. LCD Red Brightness Adjustment
Adjusting method:
1. Adjust LCD “R Bright” so that the amplitude of the CL411 waveform is VG ± 0.1 Vp-p with respect to the CL410 (VG) waveform.
Note:
6-2. LCD RGB Offset adjustment and 6-3. LCD Gain adjust­ment should always be carried out first.
C-6 Ver. 1/Rev.1
CL410 waveform
C. ADJUSTMENT METHODC-100/D-370
7. Lens Adjustment
Adjusting method:
1. LH Plate is exchanged for LH Plate2 (VE383000) for the
adjustment with the mark. (It is cut at 10°.)
VG
2. A FC ring should be pressure in the CCD direction by
about 150g. A chart is 1.2m from the front of the lens. As for the chart, Large Siemens star chart (KC0324) is used.
VG ±
0.1 Vp-p
CL4111 waveform
6-5. LCD Blue Brightness Adjustment
Adjusting method:
1. Adjust LCD “B Bright” so that the amplitude of the CL412 waveform is VG ± 0.1 Vp-p with respect to the CL410 (VG) waveform.
Note:
6-2. LCD RGB Offset adjustment and 6-3. LCD Gain adjust­ment have done.
VG
The screw is
completely
tightened.
The screw is
loosened.
3. It turns it until a FC ring is seen from the front of the lens
and put in the CW direction and stuck and it stops.
4. One of the mountains of Roulette of the FC ring is de­ cided as the mark. (The side of the gate)
5. It hints in the CW direction, and a FC ring is turned in CCW from the condition with making TFT on condition and confirming an image in TTL. Then, anabbreviation peak is found in TTL, and marking is done in LH Plate2.
6. It is returned by five in the CW direction from the mark­ ing position. That is decided with the start position, and turning it one indication toward CCW, and shoot one photography.Repeating this ten times and shoot it ten photography.
7. An image is confirmed with the PC, and a FC ring is checked with the best, and screw of LH Plate2 is fas­ tened and fixed. (A FC ring is always turned in the CCW direction from the CW direction and checked.)
CL410 waveform
CL412 waveform
VG ±
0.1Vp-p
C-7Ver.1/Rev.2
C. ADJUSTMENT METHOD C-100/D-370
[8] Adjustm ent Items
Changed repair parts
Adjustment items
CCD
LENS
CP1
1. 5.1V(A) Voltage Adjustment *1¡
2. AWB Adjustment ¡¡¡
3. Color Adjustmen ¡¡¡
4. CCD Defect Detect Adjustment ¡¡¡
5. CCD Black Point
and White Point Defect Detect ¡¡¡ 6-1. LCD H AFC Adjustment ¡ 6-2. LCD RGB Offset Adjustment ¡ 6-3. LCD Gain Adjustment ¡ 6-4. LCD Red Brightness Adjustment ¡ 6-5. LCD Blue Brightness Adjustment ¡
7. Lens Adjustment ¡¡¡
*note)There is no need that you adjust the provided CP1 when changing it without changing the parts of component level.
C-8 Ver. 1/Rev.1
C. ADJUSTMENT METHOD C-100/D-370
C-9 Ver. 1
Loading...