NEC plasma display
External Control Manual
(for PX-42VP5/42XM5/42XM3/50XM4/61XM3)
Application
These specifications are applicable to NEC plasma monitors and communications control from external equipment.
"Please also support the command of VP series and refer to the manual of the conventional model about specification."
Connections
Connections should be made as described below.
External equipment
plasma monitor
e.g., Personal computer
1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.
Type of connector: D-Sub 9-pin male
No. |
Pin Name |
|
|
1 |
No Connection |
|
|
2 |
RXD (Receive data) |
|
|
3 |
TXD (Transmit data) |
|
|
4 |
DTR (DTE side ready) |
|
|
5 |
GND |
6 |
DSR (DCE side ready) |
7 |
RTS (Ready to send) |
8 |
CTS (Clear to send) |
|
|
9 |
No Connection |
2
2)Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is to be connected for the type of connector and the pin assignment.
3)Wiring
Use a crossed (reverse) cable.
Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS (Clear to send).
Communication Parameters
(1) |
Communication system |
Asynchronous |
(2) |
Interface |
RS-232C |
(3) |
Baud rate |
9600 bps |
(4) |
Data length |
8 bits |
(5) |
Parity |
Odd |
(6) |
Stop bit |
1 bit |
(7) |
Communication code |
Hex |
3
Communication Format
8bit |
|
8bit |
|
8bit |
|
8bit |
|
8bit |
|
8bit |
|
8bit |
|
8bit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Command 1
Unit ID 1
Unit ID 2
Command 2
Data length
Data
Check sum
Command1
Command 1, along with command 2, is a number used to distinguish each command.
When making it operate using ID, bit1 and bit0 are set up as follows.
Bit1,Bit0 Unit ID distinction bit
11B |
:Usually, a form (with no ID) |
10B |
:Usually, a form (with no ID) |
01B |
:Set ID |
00B |
:Video wall ID |
In the case of ACK, when the lower order 4 bits is FH (as in 3FH and 7FH), this indicates that the commands and data of the supported equipment have been received. When the lower order 4 bits is BH (as in 3BH and 7BH), this indicates that unsupported commands and data have been received.
Unit ID1,2 (UA1,UA2)
Unit ID 1 and unit ID 2 are numbers used to identify the equipment that is to be connected.
60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer.
4
1)Unit ID 1: Indicates the equipment sending the signal. When supporting Set ID by the command 1, 4 bits of low ranks of Set ID are set up.
2)Unit ID 2: Indicates the equipment receiving the signal. When supporting Set ID by the command 1, 4 bits of higher ranks of Set ID are set up.
* Set ID : it is the apparatus number assigned to each plasma monitor.
5
Command 2
Command 2, along with command 1, is a number used to distinguish each command.
Check Sum (CKS), Error Processing, and ACK
1)The check sum described below and RS-232C odd parity are used together for a check of the received data. The check sum is the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2, Command 2, Data Length, and Data.
Check Sum Example
DFH |
80H |
60H |
47H |
01H |
01H |
08H |
||
Command1 |
Unit ID1 |
Unit ID2 |
Command2 |
Data Length |
Data |
Check Sum |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total 208H
2) Error Processing
•When the communication interval is vacant for more than 4 ms, thereafter a received Command 1 will be recognized. If, at this time, meaningful data cannot be recognized, that data will not be recognized (as valid data).
•An ACK will not be returned unless the receive data error, the check sum error, and the receive data are all taken in.
6
The control method of the set by Set ID
When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable individually.
The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below.
It is not based on ID but is the POWER ON command to all sets. 9F 80 60 4E 00 CD
In ID= "5", the value of ID-1=4 is set up. 9D 84 60 4E 00 CF
The example of a change in the single mode of a 4th page multi-system configuration and the multi-mode is shown below.
ID of the set used as a master(etc PC) is set to 50, and it assumes that ID is shaken by AUTO ID to each set. ID shaken at each set is as follows.
Upper left set (master) ID = 50 = 32h
Upper right set ID = 51 = 33h
Lower right set ID = 52 = 34h
Lower left set ID = 53 = 35h
Transmission Data
DD |
81 |
63 |
03 |
03 |
03 |
01 |
00 |
CB |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DD |
82 |
63 |
03 |
03 |
03 |
02 |
00 |
CD |
|||
|
|
|
|
|
|
|
|
|
|
|
|
DD |
83 |
63 |
03 |
03 |
03 |
03 |
00 |
CF |
|||
|
|
|
|
|
|
|
|
|
|
||
DD |
84 |
63 |
03 |
03 |
03 |
04 |
00 |
D1 |
Transmission of the above command performs a 4th page multi SPLIT display. Moreover, the following commands are published in order to change a 4th page multi-display into a single mode display.
DF 80 60 03 03 01 01 00 C7
All sets become a single mode display by the above-mentioned command. Since this command does not specify Set ID, all sets execute it.
*:Control by ID may not be able to be performed depending on connection with external control apparatus.
7
Command Reference List
|
|
CMD1 |
CMD2 |
LEN |
01 |
Power ON |
9FH |
4EH |
00H |
02 |
Power OFF |
9FH |
4FH |
00H |
03 |
Input Switch Change |
DFH |
47H |
01H |
04 |
VOLUME Gain Data |
DFH |
7FH |
03H |
05 |
AUDIO Mute ON |
9FH |
3EH |
00H |
06 |
AUDIO Mute OFF |
9FH |
3FH |
00H |
07 |
CONTRAST Gain Data |
DFH |
7FH |
03H |
08 |
BRIGHT Gain Data |
DFH |
7FH |
03H |
09 |
SHARPNESS Gain Data |
DFH |
7FH |
03H |
10 |
Color Gain Data |
DFH |
7FH |
03H |
11 |
TINT Gain Data |
DFH |
7FH |
03H |
12 |
PICTURE MODE Select |
DFH |
0AH |
01H |
13 |
COLOR TEMP SELECT |
DFH |
00H |
01H |
14 |
RED Gain Data |
DFH |
7FH |
04H |
15 |
GREEN Gain Data |
DFH |
7FH |
04H |
16 |
BLUE Gain Data |
DFH |
7FH |
04H |
17 |
NR MODE Set |
DFH |
C0H |
01H |
18 |
BASS Gain Data |
DFH |
7FH |
03H |
19 |
TREBLE Gain Data |
DFH |
7FH |
03H |
20 |
BALANCE Gain Data |
DFH |
7FH |
03H |
21 |
SCREEN MODE Select |
DFH |
51H |
01H |
22 |
V.POSITION Gain Data |
DFH |
7FH |
03H |
23 |
H.POSITION Gain Data |
DFH |
7FH |
03H |
24 |
V-HEIGHT Gain Data |
DFH |
7FH |
03H |
25 |
H-WIDTH Gain Data |
DFH |
7FH |
03H |
26 |
AUTO PICTURE Select |
DFH |
7FH |
03H |
27 |
PHASE Gain Data |
DFH |
7FH |
03H |
28 |
CLOCK Gain Data |
DFH |
7FH |
03H |
29 |
OSM Select |
DFH |
58H |
01H |
30 |
OSM ADJ. Gain Data |
DFH |
1AH |
02H |
31 |
POWER MGT Select |
DFH |
1AH |
02H |
32 |
GRAY LEVEL Set |
DFH |
C6H |
01H |
33 |
CINEMA MODE Set |
DFH |
C1H |
01H |
34 |
LONG LIFE Set |
DFH |
6BH |
03H |
35 |
INVESE Set |
DFH |
C7H |
03H |
36 |
SCREEN WIPER Set |
DFH |
C8H |
04H |
37 |
RESET |
1FH |
54H |
00H |
38 |
Audio Select Set |
DFH |
70H |
02H |
39 |
BNC INPUT |
DFH |
8CH |
01H |
40 |
RGB Select |
DFH |
8BH |
01H |
41 |
HD Select |
DFH |
8AH |
01H |
42 |
LANGUAGE Select |
DFH |
5BH |
01H |
8
43 |
COLOR SYSTEM Select |
DFH |
5CH |
01H |
44 |
FREQUENCY Request |
1FH |
26H |
00H |
45 |
Input MODE Request |
1FH |
41H |
00H |
46 |
VIDEO ADJ Request |
1FH |
45H |
00H |
47 |
Audio Select Request |
1FH |
6FH |
00H |
48 |
Failure Mode Request |
1FH |
3FH |
00H |
49 |
MODEL NAME Request |
1FH |
17H |
00H |
50 |
D-SUB INPUT |
DFH |
8DH |
01H |
51 |
TIMER SWITCH |
DFH |
02H |
01H |
52 |
LOW TONE |
DFH |
0CH |
01H |
53 |
COLOR TUNE |
DFH |
0DH |
08H |
54 |
TIMER PROGRAM SETTING |
DFH |
30H |
08H |
55 |
PRESENT TIME SETTING |
DFH |
31H |
03H |
56 |
MULTI MODE Select |
DFH |
03H |
03H |
57 |
MULTI MODE Request |
1FH |
3BH |
00H |
58 |
AUTO ID SET START |
5FH |
F0H |
01H |
59 |
PLE LINK |
DFH |
F1H |
03H |
60 |
VIDEO WALL SETTING |
DFH |
F3H |
02H |
61 |
POWER DELAY ON |
DFH |
F2H |
01H |
|
(DIVIDER setting : 1/4/9) |
|
|
|
62 |
POWER DELAY ON |
DFH |
F6H |
01H |
|
(DIVIDER setting : 16/25) |
|
|
|
63 |
GAMMA Gain Data |
DFH |
13H |
04H |
64 |
Running Sense |
1FH |
88H |
00H |
65 |
ORBITTER SET |
DFH |
1EH |
04H |
66 |
OSM OBITER |
DFH |
5FH |
01H |
67 |
OSM ANGLE |
DFH |
60H |
01H |
68 |
Input Skip |
5FH |
61H |
01H |
69*1 |
PICTURE Size |
DFH |
2AH |
01H |
70 |
OPTION Select |
DFH |
63H |
04H |
71 |
REPEAT Timer |
DFH |
64H |
06H |
72 |
SERIAL No. Request |
1FH |
15H |
00H |
73 |
S1/S2 SELECT |
DFH |
89H |
01H |
74 |
SOFT FOCUS |
DFH |
65H |
01H |
75 |
PLUG and PLAY |
DFH |
8EH |
01H |
76 |
DIGITAL SIGNAL |
DFH |
8FH |
01H |
|
LEVEL SELECT |
|
|
|
77*1 |
MULTI(SPRIT) SCREEN |
DFH |
07H |
01H |
|
Select |
|
|
|
78*1 |
SUB.P DETECT |
DFH |
7AH |
01H |
79*1 |
ZOOM NAV |
DFH |
7BH |
01H |
80*1 |
PIC FREEZE |
DFH |
7CH |
01H |
81*1 |
PAUSE COMMAND |
DFH |
7DH |
01H |
82*1 |
SEAMLESS SW |
DFH |
7EH |
03H |
83*1 |
MULTI(SPRIT) SCREEN |
DFH |
32H |
0AH |
|
PROGRAM TIMER |
|
|
|
9
84*1 |
MULTI(SPRIT) SCREEN |
DFH |
33H |
04H |
|
POWER ON MODE |
|
|
|
85*1 |
MULTI(SPRIT) SCREEN |
DFH |
34H |
09H |
|
REPEAT TIMER |
|
|
|
86 |
OSM CONTRAST |
DFH |
37H |
01H |
87*2 |
CLOSECAPTION |
DFH |
3CH |
01H |
|
(Closed Caption) |
|
|
|
88*2 |
CAPTION CONT |
DFH |
3DH |
01H |
*1:This function is only 50 or 61 inch model *2:This function is only A version
10
01. Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4EH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched on.
3FH 60H 80H 4EH 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
02. Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4FH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched off.
3FH 60H 80H 4FH 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
11
03. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH 80H 60H 47H 01H |
DATA00 CKS |
|
|
DATA00 : Input Select |
01H : Video1 |
||
|
02H |
: Video2 |
|
|
03H |
: Video3 |
|
|
05H |
: HD (HD1 or DTV or DTV1) |
|
|
06H |
: HD2(DTV2 or SCART1/SCART2) |
|
|
07H |
: RGB1 / PC1 |
|
|
08H |
: RGB2 / PC2 |
|
|
0CH : RGB3 / PC3 |
||
|
0DH : HD3(SCART3) |
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 47H 00H CKS
12
04. VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
|
DATA00: USER SOUND Gain Flag |
05H |
|
|
DATA01: VOLUME Gain Flag |
01H |
|
|
DATA02: VOLUME Gain |
00H: Step0 |
|
|
|
: |
|
|
|
0AH: Step10 (Default) |
|
|
|
: |
|
|
|
2AH: Step42 |
|
ACK |
|
|
|
|
|
|
|
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS |
||
|
DATA00: USER SOUND Gain Flag |
05H |
|
|
DATA01: VOLUME Gain Flag |
01H |
05. AUDIO Mute ON
Function
The external control equipment switches on AUDIO Mute of the plasma monitor.
Transmission Data
9FH 80H 60H 3EH 00H CKS
ACK
3FH 60H 80H 3EH 00H CKS
06. AUDIO Mute OFF
Function
The external control equipment switches off AUDIO Mute of the plasma monitor.
Transmission Data
9FH 80H 60H 3FH 00H CKS
ACK
3FH 60H 80H 3FH 00H CKS
13
07. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma c
Transmission Data
|
DFH 80H 60H 7FH 03H DATA00 |
DATA01 DATA02 CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
|
|
DATA01 : CONTRAST Gain Flag |
07H |
|
|
|
DATA02 : CONTRAST Gain |
CCH : -52 |
||
|
|
: |
|
|
|
|
FFH : -01 |
||
|
|
00H |
: 0 |
|
|
|
01H |
: +01 |
|
|
|
: |
|
|
|
|
14H |
: +20 |
|
ACK |
|
|
|
|
|
|
|
||
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS |
|||
|
DATA00: USER PICTURE Gain Flag |
01H |
|
|
|
DATA01: CONTRAST Gain Flag |
07H |
|
|
08. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma monitor.
Transmission Data
|
DFH 80H 60H 7FH 03H DATA00 |
DATA01 |
DATA02 CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
|
|
|
DATA01 : BRIGHT Gain Flag |
08H |
|
|
|
|
DATA02 : BRIGHT Gain |
E0H : -32 |
|
|
|
|
|
: |
|
|
|
|
|
FFH : -01 |
|
|
|
|
|
00H |
: 0 |
|
|
|
|
01H |
: +01 |
|
|
|
|
: |
|
|
|
|
|
20H |
: +32 |
|
|
ACK |
|
|
|
|
|
|
|
|
|
|
|
|
7FH 60H 80H 7FH 02H DATA00 |
DATA01 |
CKS |
||
14 |
|
|
|
|
DATA00 |
: USER PICTURE Gain Flag |
01H |
DATA01 |
: BRIGHT Gain Flag |
08H |
09. SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the plasma monitor.
Transmission Data
|
DFH 80H 60H 7FH 03H DATA00 |
DATA01 |
DATA02 CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
|
|
|
DATA01 : SHARPNESS Gain Flag |
06H |
|
|
|
|
DATA02 : SHARPNESS Gain |
F0H : -16 |
|
|
|
|
|
: |
|
|
|
|
|
FFH : -01 |
|||
|
|
00H |
: 0 |
|
|
|
|
01H |
: +01 |
|
|
|
|
: |
|
|
|
|
|
10H |
: +16 |
|
|
|
Only when a RGB signal is connected |
|
|
|
|
|
DATA02 : SHARPNESS Gain |
01H |
: 1 |
|
|
|
|
02H |
: 2 |
|
|
|
|
03H |
: 3 |
|
|
|
|
04H |
: 4 |
|
|
ACK |
|
|
|
|
|
|
|
|
|
|
|
|
7FH 60H 80H 7FH 02H DATA00 |
DATA01 |
CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
|
|
|
DATA01 : SHARPNESS Gain Flag |
06H |
|
|
|
15
10. COLOR Gain Data
Function
The external control equipment changes the COLOR gain data of the plasma monitor.
Transmission Data
|
DFH 80H 60H 7FH 03H DATA00 |
DATA01 DATA02 CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
|
|
DATA01 : COLOR Gain Flag |
04H |
|
|
|
DATA02 : COLOR Gain |
E0H : -32 |
||
|
|
: |
|
|
|
|
FFH : -01 |
||
|
|
00H |
: 0 |
|
|
|
01H |
: +01 |
|
|
|
: |
|
|
|
|
20H |
: +32 |
|
* COLOR Gain is from -22 (EAH) to +22 (16H) only during video. |
||||
ACK |
|
|
|
|
|
|
|
||
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS |
|||
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
|
|
DATA01 : COLOR Gain Flag |
04H |
|
|
11. TINT Gain Data
Function
The external control equipment changes the TINT gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 |
DATA01 DATA02 CKS |
|
DATA00 : USER PICTURE Gain Flag |
01H |
|
DATA01 : TINT Gain Flag |
05H |
|
DATA02 : TINT Gain |
E0H: -32 |
|
|
: |
|
* TINT Gain is from -22 (EAH) to |
FFH : -01 |
|
+22 (16H) only during video. |
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
|
20H |
: +32 |
16 |
|
|
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag |
01H |
DATA01 : TINT Gain Flag |
05H |
12. PICTURE MODE Select
Function
The external control equipment sets the picture mode of the plasma monitor. Transmission Data
DFH 80H 60H 0AH 01H DATA00 CKS
DATA00: 01H : NORMAL
02H : THEATER1(It cannot choose in the still picture input of a personal computer.)
03H : THEATER2(It cannot choose in the still picture input of a personal computer.)
04H : Default
05H : Bright
ACK
7FH 60H 80H 0AH 01H DATA00 CKS
DATA00: 01H : NORMAL 02H : THEATER1 03H : THEATER2 04H : Default 05H : Bright
13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00 : 00H: low 01H: middle 02H: high
03H: middle low
17
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00 : 00H: low 01H: middle 02H: high
03H: middle low
14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag |
01H |
|
DATA01 : RED Gain Flag |
01H |
|
DATA02 : RED Gain1(Bias) |
D8H : -40 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
|
1EH : +30 |
|
DATA03: RED Gain2(Drive) |
D8H : -40 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag |
01H |
DATA01 : RED Gain Flag |
01H |
18
15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag |
01H |
|
DATA01 : GREEN Gain Flag |
02H |
|
DATA02 : GREEN Gain1(Bias) |
D8H : -40 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
|
1EH : +30 |
|
DATA03: GREEN Gain2(Drive) |
D8H : -40 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
|
: |
|
1EH : +30 |
|
ACK |
|
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag |
01H |
DATA01: GREEN Gain Flag |
02H |
19
16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag |
01H |
|
DATA01 : BLUE Gain Flag |
03H |
|
DATA02 : BLUE Gain1(Bias) |
D8H :-40 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
|
1EH : +30 |
|
DATA03: BLUE Gain2(Drive) |
D8H :-40 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag |
01H |
DATA01: BLUE Gain Flag |
03H |
20
17.NR MODE Set
Function
The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor.
Transmission Data
DFH 80H 60H C0H 01H DATA00 CKS
DATA00: 01H : NR OFF 02H : NR-1 03H : NR-2 04H : NR-3
ACK
7FH 60H 80H C0H 01H DATA00 CKS
DATA00: 01H : NR OFF 02H : NR-1 03H : NR-2 04H : NR-3
18.BASS Gain Data
Function
The external control equipment changes the BASS gain data of the plasma monitor.
Transmission Data
|
DFH 80H 60H 7FH 03H DATA00 |
DATA01 DATA02 CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
05H |
|
|
|
DATA01 : BASS Gain Flag |
03H |
|
|
|
DATA02 : BASS Gain |
F3H : -13 |
||
|
|
: |
|
|
|
|
FFH : -01 |
||
|
|
00H |
: 0 |
|
|
|
01H |
: +01 |
|
|
|
: |
|
|
|
|
0DH : +13 |
||
ACK |
|
|
|
|
|
|
|
||
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS |
|||
|
DATA00 : USER PICTURE Gain Flag |
05H |
|
|
|
DATA01 : BASS Gain Flag |
03H |
|
|
21 |
|
|
|
19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 |
DATA01 DATA02 CKS |
|
DATA00 : USER PICTURE Gain Flag |
05H |
|
DATA01 : TREBLE Gain Flag |
04H |
|
DATA02 : TREBLE Gain |
F3H : -13 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
0DH : +13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag |
05H |
DATA01: TREBLE Gain Flag |
04H |
20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
|
DFH 80H 60H 7FH 03H DATA00 |
DATA01 DATA02 |
CKS |
||
|
DATA00 : USER PICTURE Gain Flag |
05H |
|
|
|
|
DATA01 : BALANCE Gain Flag |
02H |
|
|
|
|
DATA02 : BALANCE Gain |
EAH : -22 |
|
|
|
|
|
: |
|
|
|
|
|
FFH : -01 |
|
|
|
|
|
00H |
: 0 |
|
|
|
|
01H |
: +01 |
|
|
|
|
: |
|
|
|
|
|
16H |
: +22 |
|
|
ACK |
|
|
|
|
|
|
|
|
|
|
|
|
7FH 60H 80H 7FH 02H DATA00 |
|
DATA01 |
CKS |
|
|
DATA00: USER PICTURE Gain Flag |
05H |
|
|
|
22 |
|
|
|
|
DATA01: BALANCE Gain Flag |
02H |
21.SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H 60H 51H 01H DATA00 CKS
DATA00 02H : STADIUM 03H : ZOOM 04H : NORMAL 05H : FULL 06H : REAL
08H : UNDERSCAN
09H : 14:9 0AH : 2.35:1
ACK
7FH 60H 80H 51H 01H DATA00 CKS
DATA00 02H : STADIUM 03H : ZOOM 04H : NORMAL 05H : FULL 06H : REAL
08H : UNDERSCAN
09H : 14:9 0AH : 2.35:1
23
22. V.POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag |
03H |
|
DATA01 : V.POSITION Gain Flag |
01H |
|
DATA02 : V.POSITION Gain |
C0H : -64 |
|
|
: |
|
|
FFH : -01 |
|
|
00H |
: 0 |
|
01H |
: +01 |
|
: |
|
|
40H |
: +64 |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag |
03H |
DATA01: V.POSITION Gain Flag |
01H |
24