Nec PX-42VP5, PX-42XM5, PX-42XM3, PX-50XM4, PX-61XM3 External Control Manual

0 (0)

NEC plasma display

External Control Manual

(for PX-42VP5/42XM5/42XM3/50XM4/61XM3)

Nec PX-42VP5, PX-42XM5, PX-42XM3, PX-50XM4, PX-61XM3 External Control Manual

Application

These specifications are applicable to NEC plasma monitors and communications control from external equipment.

"Please also support the command of VP series and refer to the manual of the conventional model about specification."

Connections

Connections should be made as described below.

External equipment

plasma monitor

e.g., Personal computer

1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.

Type of connector: D-Sub 9-pin male

No.

Pin Name

 

 

1

No Connection

 

 

2

RXD (Receive data)

 

 

3

TXD (Transmit data)

 

 

4

DTR (DTE side ready)

 

 

5

GND

6

DSR (DCE side ready)

7

RTS (Ready to send)

8

CTS (Clear to send)

 

 

9

No Connection

2

2)Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is to be connected for the type of connector and the pin assignment.

3)Wiring

Use a crossed (reverse) cable.

Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS (Clear to send).

Communication Parameters

(1)

Communication system

Asynchronous

(2)

Interface

RS-232C

(3)

Baud rate

9600 bps

(4)

Data length

8 bits

(5)

Parity

Odd

(6)

Stop bit

1 bit

(7)

Communication code

Hex

3

Communication Format

8bit

 

8bit

 

8bit

 

8bit

 

8bit

 

8bit

 

8bit

 

8bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command 1

Unit ID 1

Unit ID 2

Command 2

Data length

Data

Check sum

Command1

Command 1, along with command 2, is a number used to distinguish each command.

When making it operate using ID, bit1 and bit0 are set up as follows.

Bit1,Bit0 Unit ID distinction bit

11B

:Usually, a form (with no ID)

10B

:Usually, a form (with no ID)

01B

:Set ID

00B

:Video wall ID

In the case of ACK, when the lower order 4 bits is FH (as in 3FH and 7FH), this indicates that the commands and data of the supported equipment have been received. When the lower order 4 bits is BH (as in 3BH and 7BH), this indicates that unsupported commands and data have been received.

Unit ID1,2 (UA1,UA2)

Unit ID 1 and unit ID 2 are numbers used to identify the equipment that is to be connected.

60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer.

4

1)Unit ID 1: Indicates the equipment sending the signal. When supporting Set ID by the command 1, 4 bits of low ranks of Set ID are set up.

2)Unit ID 2: Indicates the equipment receiving the signal. When supporting Set ID by the command 1, 4 bits of higher ranks of Set ID are set up.

* Set ID : it is the apparatus number assigned to each plasma monitor.

5

Command 2

Command 2, along with command 1, is a number used to distinguish each command.

Check Sum (CKS), Error Processing, and ACK

1)The check sum described below and RS-232C odd parity are used together for a check of the received data. The check sum is the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2, Command 2, Data Length, and Data.

Check Sum Example

DFH

80H

60H

47H

01H

01H

08H

Command1

Unit ID1

Unit ID2

Command2

Data Length

Data

Check Sum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total 208H

2) Error Processing

When the communication interval is vacant for more than 4 ms, thereafter a received Command 1 will be recognized. If, at this time, meaningful data cannot be recognized, that data will not be recognized (as valid data).

An ACK will not be returned unless the receive data error, the check sum error, and the receive data are all taken in.

6

The control method of the set by Set ID

When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable individually.

The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below.

It is not based on ID but is the POWER ON command to all sets. 9F 80 60 4E 00 CD

In ID= "5", the value of ID-1=4 is set up. 9D 84 60 4E 00 CF

The example of a change in the single mode of a 4th page multi-system configuration and the multi-mode is shown below.

ID of the set used as a master(etc PC) is set to 50, and it assumes that ID is shaken by AUTO ID to each set. ID shaken at each set is as follows.

Upper left set (master) ID = 50 = 32h

Upper right set ID = 51 = 33h

Lower right set ID = 52 = 34h

Lower left set ID = 53 = 35h

Transmission Data

DD

81

63

03

03

03

01

00

CB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DD

82

63

03

03

03

02

00

CD

 

 

 

 

 

 

 

 

 

 

 

DD

83

63

03

03

03

03

00

CF

 

 

 

 

 

 

 

 

 

 

DD

84

63

03

03

03

04

00

D1

Transmission of the above command performs a 4th page multi SPLIT display. Moreover, the following commands are published in order to change a 4th page multi-display into a single mode display.

DF 80 60 03 03 01 01 00 C7

All sets become a single mode display by the above-mentioned command. Since this command does not specify Set ID, all sets execute it.

*:Control by ID may not be able to be performed depending on connection with external control apparatus.

7

Command Reference List

 

 

CMD1

CMD2

LEN

01

Power ON

9FH

4EH

00H

02

Power OFF

9FH

4FH

00H

03

Input Switch Change

DFH

47H

01H

04

VOLUME Gain Data

DFH

7FH

03H

05

AUDIO Mute ON

9FH

3EH

00H

06

AUDIO Mute OFF

9FH

3FH

00H

07

CONTRAST Gain Data

DFH

7FH

03H

08

BRIGHT Gain Data

DFH

7FH

03H

09

SHARPNESS Gain Data

DFH

7FH

03H

10

Color Gain Data

DFH

7FH

03H

11

TINT Gain Data

DFH

7FH

03H

12

PICTURE MODE Select

DFH

0AH

01H

13

COLOR TEMP SELECT

DFH

00H

01H

14

RED Gain Data

DFH

7FH

04H

15

GREEN Gain Data

DFH

7FH

04H

16

BLUE Gain Data

DFH

7FH

04H

17

NR MODE Set

DFH

C0H

01H

18

BASS Gain Data

DFH

7FH

03H

19

TREBLE Gain Data

DFH

7FH

03H

20

BALANCE Gain Data

DFH

7FH

03H

21

SCREEN MODE Select

DFH

51H

01H

22

V.POSITION Gain Data

DFH

7FH

03H

23

H.POSITION Gain Data

DFH

7FH

03H

24

V-HEIGHT Gain Data

DFH

7FH

03H

25

H-WIDTH Gain Data

DFH

7FH

03H

26

AUTO PICTURE Select

DFH

7FH

03H

27

PHASE Gain Data

DFH

7FH

03H

28

CLOCK Gain Data

DFH

7FH

03H

29

OSM Select

DFH

58H

01H

30

OSM ADJ. Gain Data

DFH

1AH

02H

31

POWER MGT Select

DFH

1AH

02H

32

GRAY LEVEL Set

DFH

C6H

01H

33

CINEMA MODE Set

DFH

C1H

01H

34

LONG LIFE Set

DFH

6BH

03H

35

INVESE Set

DFH

C7H

03H

36

SCREEN WIPER Set

DFH

C8H

04H

37

RESET

1FH

54H

00H

38

Audio Select Set

DFH

70H

02H

39

BNC INPUT

DFH

8CH

01H

40

RGB Select

DFH

8BH

01H

41

HD Select

DFH

8AH

01H

42

LANGUAGE Select

DFH

5BH

01H

8

43

COLOR SYSTEM Select

DFH

5CH

01H

44

FREQUENCY Request

1FH

26H

00H

45

Input MODE Request

1FH

41H

00H

46

VIDEO ADJ Request

1FH

45H

00H

47

Audio Select Request

1FH

6FH

00H

48

Failure Mode Request

1FH

3FH

00H

49

MODEL NAME Request

1FH

17H

00H

50

D-SUB INPUT

DFH

8DH

01H

51

TIMER SWITCH

DFH

02H

01H

52

LOW TONE

DFH

0CH

01H

53

COLOR TUNE

DFH

0DH

08H

54

TIMER PROGRAM SETTING

DFH

30H

08H

55

PRESENT TIME SETTING

DFH

31H

03H

56

MULTI MODE Select

DFH

03H

03H

57

MULTI MODE Request

1FH

3BH

00H

58

AUTO ID SET START

5FH

F0H

01H

59

PLE LINK

DFH

F1H

03H

60

VIDEO WALL SETTING

DFH

F3H

02H

61

POWER DELAY ON

DFH

F2H

01H

 

(DIVIDER setting : 1/4/9)

 

 

 

62

POWER DELAY ON

DFH

F6H

01H

 

(DIVIDER setting : 16/25)

 

 

 

63

GAMMA Gain Data

DFH

13H

04H

64

Running Sense

1FH

88H

00H

65

ORBITTER SET

DFH

1EH

04H

66

OSM OBITER

DFH

5FH

01H

67

OSM ANGLE

DFH

60H

01H

68

Input Skip

5FH

61H

01H

69*1

PICTURE Size

DFH

2AH

01H

70

OPTION Select

DFH

63H

04H

71

REPEAT Timer

DFH

64H

06H

72

SERIAL No. Request

1FH

15H

00H

73

S1/S2 SELECT

DFH

89H

01H

74

SOFT FOCUS

DFH

65H

01H

75

PLUG and PLAY

DFH

8EH

01H

76

DIGITAL SIGNAL

DFH

8FH

01H

 

LEVEL SELECT

 

 

 

77*1

MULTI(SPRIT) SCREEN

DFH

07H

01H

 

Select

 

 

 

78*1

SUB.P DETECT

DFH

7AH

01H

79*1

ZOOM NAV

DFH

7BH

01H

80*1

PIC FREEZE

DFH

7CH

01H

81*1

PAUSE COMMAND

DFH

7DH

01H

82*1

SEAMLESS SW

DFH

7EH

03H

83*1

MULTI(SPRIT) SCREEN

DFH

32H

0AH

 

PROGRAM TIMER

 

 

 

9

84*1

MULTI(SPRIT) SCREEN

DFH

33H

04H

 

POWER ON MODE

 

 

 

85*1

MULTI(SPRIT) SCREEN

DFH

34H

09H

 

REPEAT TIMER

 

 

 

86

OSM CONTRAST

DFH

37H

01H

87*2

CLOSECAPTION

DFH

3CH

01H

 

(Closed Caption)

 

 

 

88*2

CAPTION CONT

DFH

3DH

01H

*1:This function is only 50 or 61 inch model *2:This function is only A version

10

01. Power ON

Function

The external control equipment switches on the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4EH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched on.

3FH 60H 80H 4EH 00H CKS

NOTE: Do not set the Power ON or Power OFF command continuously.

02. Power OFF

Function

The external control equipment switches off the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4FH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched off.

3FH 60H 80H 4FH 00H CKS

NOTE: Do not set the Power ON or Power OFF command continuously.

11

03. Input Switch Change

Function

The external control equipment switches the input of the plasma monitor.

Transmission Data

DFH 80H 60H 47H 01H

DATA00 CKS

 

DATA00 : Input Select

01H : Video1

 

02H

: Video2

 

03H

: Video3

 

05H

: HD (HD1 or DTV or DTV1)

 

06H

: HD2(DTV2 or SCART1/SCART2)

 

07H

: RGB1 / PC1

 

08H

: RGB2 / PC2

 

0CH : RGB3 / PC3

 

0DH : HD3(SCART3)

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 47H 00H CKS

12

04. VOLUME Gain Data

Function

The external control equipment changes the VOLUME gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

 

DATA00: USER SOUND Gain Flag

05H

 

DATA01: VOLUME Gain Flag

01H

 

DATA02: VOLUME Gain

00H: Step0

 

 

:

 

 

 

0AH: Step10 (Default)

 

 

:

 

 

 

2AH: Step42

ACK

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00: USER SOUND Gain Flag

05H

 

DATA01: VOLUME Gain Flag

01H

05. AUDIO Mute ON

Function

The external control equipment switches on AUDIO Mute of the plasma monitor.

Transmission Data

9FH 80H 60H 3EH 00H CKS

ACK

3FH 60H 80H 3EH 00H CKS

06. AUDIO Mute OFF

Function

The external control equipment switches off AUDIO Mute of the plasma monitor.

Transmission Data

9FH 80H 60H 3FH 00H CKS

ACK

3FH 60H 80H 3FH 00H CKS

13

07. CONTRAST Gain Data

Function

The external control equipment changes the CONTRAST gain data of the plasma c

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

01H

 

 

 

DATA01 : CONTRAST Gain Flag

07H

 

 

 

DATA02 : CONTRAST Gain

CCH : -52

 

 

:

 

 

 

 

FFH : -01

 

 

00H

: 0

 

 

 

01H

: +01

 

 

 

:

 

 

 

 

14H

: +20

 

ACK

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00: USER PICTURE Gain Flag

01H

 

 

 

DATA01: CONTRAST Gain Flag

07H

 

 

08. BRIGHT Gain Data

Function

The external control equipment changes the BRIGHT gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01

DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

01H

 

 

 

 

DATA01 : BRIGHT Gain Flag

08H

 

 

 

 

DATA02 : BRIGHT Gain

E0H : -32

 

 

 

 

:

 

 

 

 

 

FFH : -01

 

 

 

 

00H

: 0

 

 

 

 

01H

: +01

 

 

 

 

:

 

 

 

 

 

20H

: +32

 

 

ACK

 

 

 

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00

DATA01

CKS

14

 

 

 

 

DATA00

: USER PICTURE Gain Flag

01H

DATA01

: BRIGHT Gain Flag

08H

09. SHARPNESS Gain Data

Function

The external control equipment changes the SHARPNESS gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01

DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

01H

 

 

 

 

DATA01 : SHARPNESS Gain Flag

06H

 

 

 

 

DATA02 : SHARPNESS Gain

F0H : -16

 

 

 

 

:

 

 

 

 

 

FFH : -01

 

 

00H

: 0

 

 

 

 

01H

: +01

 

 

 

:

 

 

 

 

 

10H

: +16

 

 

Only when a RGB signal is connected

 

 

 

 

 

DATA02 : SHARPNESS Gain

01H

: 1

 

 

 

 

02H

: 2

 

 

 

 

03H

: 3

 

 

 

 

04H

: 4

 

 

ACK

 

 

 

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00

DATA01

CKS

 

DATA00 : USER PICTURE Gain Flag

01H

 

 

 

 

DATA01 : SHARPNESS Gain Flag

06H

 

 

 

15

10. COLOR Gain Data

Function

The external control equipment changes the COLOR gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

01H

 

 

 

DATA01 : COLOR Gain Flag

04H

 

 

 

DATA02 : COLOR Gain

E0H : -32

 

 

:

 

 

 

 

FFH : -01

 

 

00H

: 0

 

 

 

01H

: +01

 

 

 

:

 

 

 

 

20H

: +32

 

* COLOR Gain is from -22 (EAH) to +22 (16H) only during video.

ACK

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00 : USER PICTURE Gain Flag

01H

 

 

 

DATA01 : COLOR Gain Flag

04H

 

 

11. TINT Gain Data

Function

The external control equipment changes the TINT gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

01H

 

DATA01 : TINT Gain Flag

05H

 

DATA02 : TINT Gain

E0H: -32

 

:

 

* TINT Gain is from -22 (EAH) to

FFH : -01

+22 (16H) only during video.

00H

: 0

 

01H

: +01

 

:

 

 

20H

: +32

16

 

 

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : TINT Gain Flag

05H

12. PICTURE MODE Select

Function

The external control equipment sets the picture mode of the plasma monitor. Transmission Data

DFH 80H 60H 0AH 01H DATA00 CKS

DATA00: 01H : NORMAL

02H : THEATER1(It cannot choose in the still picture input of a personal computer.)

03H : THEATER2(It cannot choose in the still picture input of a personal computer.)

04H : Default

05H : Bright

ACK

7FH 60H 80H 0AH 01H DATA00 CKS

DATA00: 01H : NORMAL 02H : THEATER1 03H : THEATER2 04H : Default 05H : Bright

13. COLOR TEMP SELECT

Function

The external control equipment changes the COLOR TEMP of the plasma monitor.

Transmission Data

DFH 80H 60H 00H 01H DATA00 CKS

DATA00 : 00H: low 01H: middle 02H: high

03H: middle low

17

ACK

7FH 60H 80H 00H 01H DATA00 CKS

DATA00 : 00H: low 01H: middle 02H: high

03H: middle low

14. RED Gain Data

Function

The external control equipment changes the RED Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00 : USER PICTURE Gain Flag

01H

 

DATA01 : RED Gain Flag

01H

 

DATA02 : RED Gain1(Bias)

D8H : -40

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

 

1EH : +30

DATA03: RED Gain2(Drive)

D8H : -40

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

1EH : +30

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : RED Gain Flag

01H

18

15. GREEN Gain Data

Function

The external control equipment changes the GREEN Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00 : USER PICTURE Gain Flag

01H

 

DATA01 : GREEN Gain Flag

02H

 

DATA02 : GREEN Gain1(Bias)

D8H : -40

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

 

1EH : +30

DATA03: GREEN Gain2(Drive)

D8H : -40

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

 

:

 

1EH : +30

ACK

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

19

16. BLUE Gain Data

Function

The external control equipment changes the BLUE Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00 : USER PICTURE Gain Flag

01H

 

DATA01 : BLUE Gain Flag

03H

 

DATA02 : BLUE Gain1(Bias)

D8H :-40

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

 

1EH : +30

DATA03: BLUE Gain2(Drive)

D8H :-40

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

1EH : +30

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

20

17.NR MODE Set

Function

The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor.

Transmission Data

DFH 80H 60H C0H 01H DATA00 CKS

DATA00: 01H : NR OFF 02H : NR-1 03H : NR-2 04H : NR-3

ACK

7FH 60H 80H C0H 01H DATA00 CKS

DATA00: 01H : NR OFF 02H : NR-1 03H : NR-2 04H : NR-3

18.BASS Gain Data

Function

The external control equipment changes the BASS gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

05H

 

 

 

DATA01 : BASS Gain Flag

03H

 

 

 

DATA02 : BASS Gain

F3H : -13

 

 

:

 

 

 

 

FFH : -01

 

 

00H

: 0

 

 

 

01H

: +01

 

 

 

:

 

 

 

 

0DH : +13

ACK

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00 : USER PICTURE Gain Flag

05H

 

 

 

DATA01 : BASS Gain Flag

03H

 

 

21

 

 

 

19. TREBLE Gain Data

Function

The external control equipment changes the TREBLE gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

05H

 

DATA01 : TREBLE Gain Flag

04H

 

DATA02 : TREBLE Gain

F3H : -13

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

0DH : +13

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

20. BALANCE Gain Data

Function

The external control equipment changes the BALANCE gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02

CKS

 

DATA00 : USER PICTURE Gain Flag

05H

 

 

 

 

DATA01 : BALANCE Gain Flag

02H

 

 

 

 

DATA02 : BALANCE Gain

EAH : -22

 

 

 

 

:

 

 

 

 

 

FFH : -01

 

 

 

 

00H

: 0

 

 

 

 

01H

: +01

 

 

 

 

:

 

 

 

 

 

16H

: +22

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00

 

DATA01

CKS

 

DATA00: USER PICTURE Gain Flag

05H

 

 

 

22

 

 

 

 

DATA01: BALANCE Gain Flag

02H

21.SCREEN MODE Select

Function

The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH 80H 60H 51H 01H DATA00 CKS

DATA00 02H : STADIUM 03H : ZOOM 04H : NORMAL 05H : FULL 06H : REAL

08H : UNDERSCAN

09H : 14:9 0AH : 2.35:1

ACK

7FH 60H 80H 51H 01H DATA00 CKS

DATA00 02H : STADIUM 03H : ZOOM 04H : NORMAL 05H : FULL 06H : REAL

08H : UNDERSCAN

09H : 14:9 0AH : 2.35:1

23

22. V.POSITION Gain Data

Function

The external control equipment changes the V. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

03H

 

DATA01 : V.POSITION Gain Flag

01H

 

DATA02 : V.POSITION Gain

C0H : -64

 

:

 

 

FFH : -01

 

00H

: 0

 

01H

: +01

 

:

 

 

40H

: +64

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V.POSITION Gain Flag

01H

24

Loading...