It is essential to read the operating instructions
and service documents before installation or use
of this appliance. This will prevent both personal
injury and damage to the machine.
en - AU, NZ
M.-Nr. 10 720 840
Page 2
Installation notes
Please read and observe the operating instructions and the
service documents regarding installation and setting up of this
dishwasher.
Installation
requirements
Electrical
connection
This dishwasher must be installed by a suitably qualified person
with the appropriate electrical and plumbing qualifications in
accordance with the installation instructions supplied.
This dishwasher must be installed in accordance with all applicable
standards and guidelines, including legal requirements and health
and safety regulations.
The machine must be commissioned and operatives trained in its
use by Miele Professional Service or by an authorised Miele Service
Partner only.
Connection to the electrical supply must be in accordance with valid
legal requirements, health and safety regulations, and applicable
standards. The mains connection cable must be protected from the
risk of thermal damage.
We recommend connecting the dishwasher to the power supply via a
suitable plug and socket as this will make it easier to carry out the
electrical safety test during commissioning and after any service
work.
For hard-wired dishwashers, connection must be via a main switch
to be provided on site, which must completely isolate the machine
from the power supply with a contact gap of at least 3mm.
The plug, socket, and main switch must be easily accessible once the
dishwasher has been installed.
Equipotential
bonding and
earthing
Water connection
Environmental
requirements
For added safety, the dishwasher should be protected with a residual
current device with a trip current of 30mA.
Equipotential bonding should be carried out if required. The screw
connection point for equipotential bonding is located at the back of
the dishwasher. Equipotential bonding and earthing must be carried
out before the machine is commissioned.
This appliance must be installed according to AS/NZS3500.1. This
appliance has been supplied with a separate backflow prevention
device (non-return valve) and must be connected to the water tap..
The tap for the water supply must be easily accessible.
The dishwasher can be connected to either a cold water or hot water
supply.
Condensate can build up in the area surrounding the dishwasher.
Any cabinetry and fittings in the room must therefore be suitable for
purpose. If the machine is fitted under a suitable worktop (built-under
and integrated models), the stainless steel steam deflector plate
provided must be fitted above the door aperture to protect the
worktop from moisture damage. A matching steam deflector plate is
also available for order at a later date from Miele Professional Service.
2PG 8130 / PG 8131 / PG 8132 / PG 8133
Page 3
Installation notes
Connecting an
external
dispensing
system
A dispensing system for liquid detergent and rinse aid can be
connected at the back of the machine.
PG 8130 / PG 8131 / PG 8132 / PG 81333
Page 4
Illustrations
PG 8130-31 dimensions
PG 8132-33 XXL dimensions
4PG 8130 / PG 8131 / PG 8132 / PG 8133
Page 5
Connections at the back of the machine
On-site connections
Illustrations
KW/WWConnection to cold or hot waterELElectrical connection
AWDrain connectionPAEquipotential bonding
DSExternal dispensing
PG 8130 / PG 8131 / PG 8132 / PG 81335
Page 6
Illustrations
Machine versions
PG 8130 freestanding model
PG 8130 U/iPG 8130i / PG 8131i
PG 8130 U
PG 8132 SCi XXL
6PG 8130 / PG 8131 / PG 8132 / PG 8133
PG 8133 SCVi XXL
Page 7
Technical data
Electrical connection for PG 8130
Voltage (standard delivered)AC 230V/50Hz
Total rated load3.1kW
Fuse rating1 x 15A
Mains connection cable, min. cross-section3 x 1.5mm²
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/52.4m
Voltage (convertible)AC 230V/50Hz
Total rated load2.3kW
Fuse rating1 x 10A
Mains connection cable, min. cross-section3 x 1.5mm²
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/52.4m
Electrical connection for PG 8131, PG 8132 and PG 8133
Voltage (standard delivered)AC 230V/50Hz
Total rated load2.3kW
Fuse rating1 x 10A
Mains connection cable, min. cross-section3 x 1.5mm²
,
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/52.4m
Voltage (convertible)AC 230V/50Hz
Total rated load5.3kW
Fuse rating1 x 25A
Mains connection cable, min. cross-section3 x 4mm²
Length of mains connection cable with plug SAA/3/25 Typ HPM 106/52.4m
Water connection
Max. temperature60°C
Max. water hardness6.5 mmol/l
36°dH
On-site water pressure50 - 1000kPa
Recommended flow pressure200kPa
On-site threaded union in accordance with AS3688 (flat sealing)3/4inches
Length of cold water inlet hose1.5 m
PG 8130 / PG 8131 / PG 8132 / PG 81337
Page 8
Technical data
Drain water
Drain water temperature75°C
Standard length of drain hose1.5 m
Max. drainage length of drain hose4.0 m
Max. drain pump head height from bottom edge of machine1.0 m
Max. transient flow rate16l/min
Hose sleeves to be provided on site (ext. dia.xl)22 x 30 mm
Internal diameter of drain hose22 mm
Machine feet
Machine feet height adjustment65 mm
Diameter of machine feet30 mm
Insert for machine feet, size of thread20 mm
Machine data
Height including lid PG 8130845 mm
Building-under height PG 8130 / PG 8131805 mm
Building-under height PG 8132 XXL / PG 8133 XXL845 mm
Width PG 8130 freestanding model600 mm
Width without lid598 mm
Depth PG 8130 freestanding model600 mm
Depth without lid570 mm
Door height PG 8130 freestanding model720 mm
Door height PG 8130-31650 mm
Door height PG 8132-33 XXL690 mm
Weight PG 8130 freestanding model61.5kg
Weight PG 8130 U54.0kg
Weight PG 8130i / PG 8131i54.7kg
Weight PG 8132 SCi XXL56.2kg
Weight PG 8133 SCVi XXL56.0kg
Floor load in operation1000 N
Min. access width incl. transport pallet670 mm
Min. access depth including transport pallet690 mm
Min. access height including transport pallet970 mm
Noise level in dB (A),
sound power pressure LpA during cleaning and drying phases (ECO programme)45dB (A)
8PG 8130 / PG 8131 / PG 8132 / PG 8133
Page 9
Technical data
Ambient conditions
Permitted temperature range in operation5 - 40°C
Max. relative humidity up to 31°C80%
Relative humidity, declining proportionally to 40°C50%
Transport conditions - permitted temperature range-20 - 60°C
Transport conditions - permitted relative humidity10 - 85%
Transport conditions - permitted air pressure500 - 1060hPa