INSTALLATION PLAN
PG 8130
PG 8133
It is essential to read the operating instructions as
well as the service documentation before the
machine is installed or used for the first time.
en - US
M.-Nr. 10 783 381
Installation notes
Please read and observe the operating instructions and the
service documents regarding installation and setting up of this
dishwasher.
Installation requirements
Electrical connection
This dishwasher must be installed by a suitably qualified person
with the appropriate electrical and plumbing qualifications in ac-
cordance with the installation instructions supplied.
This dishwasher must be installed in accordance with all applicable
standards and guidelines, including legal requirements and health
and safety regulations.
The machine must be commissioned and operatives trained in its
use by Miele Technical Service or by an approved Miele Service Partner only.
Connection to the electrical supply must be in accordance with valid
legal requirements, health and safety regulations, and applicable
standards. The power cord must protected from the risk of thermal
damage.
We recommend connecting the dishwasher to the power supply via a
suitable plug and socket as this will make it easier to carry out the
electrical safety test during commissioning and after any service
work.
For hard-wired dishwashers, connection must be via a main switch
to be provided on site, which must completely isolate the machine
from the power supply with a contact gap of at least 1/8" (3mm).
The plug, socket, and main switch must be easily accessible once the
dishwasher has been installed.
Equipotential
bonding and
grounding
Water connection
Surrounding area
For added safety, the dishwasher should be protected with a residual
current device with a trip current of 30mA.
Equipotential bonding should be carried out if required. The screw
connection point for equipotential bonding is located at the back of
the dishwasher. Equipotential bonding and grounding must be carried
out before the machine is commissioned.
The machine can be plumbed in to the cold water, hot water, and
drainage points without a backflow protection device. The shut-off
valves for the water lines must be easily accessible.
The dishwasher can be connected to both cold water and hot water
points.
Condensate can build up in the area surrounding the dishwasher.
Any cabinetry and fittings in the room must therefore be suitable for
purpose. If the machine is fitted under a suitable countertop (built-under and integrated models), the stainless-steel steam protector provided must be fitted above the door aperture to protect the countertop from moisture damage. A matching steam protector is also available for order at a later date from Miele Technical Service.
2 PG 8130 / PG 8133
Installation notes
Connecting an external dispensing
system
A dispensing system for liquid detergent and rinse aid can be connected at the back of the machine.
PG 8130 / PG 8133 3