Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Electrical
connection
Country variations:
Voltage
1. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
2. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
convertible
3N AC 400/50
9.7
3 × 16
5 × 2.5
1.7
3N AC 400/50
7.3
3 × 16
5 × 2.5
1.7
3 AC 230/50
7.3
3 × 20
5 × 2.5
1.7
Voltage
Voltage
3. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
4. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead with plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
convertible
3 AC 230/50
7,3
3 × 20
5 × 2,5
1,7
3 N AC 400/50
7.3
3 × 16
5 × 2.5
1.7
3N AC 400/50
9,2
3 × 15/16
5 × 2.5
1.7
AC 230/50
6.7
1 × 30
3 × 4
2.1
Installation plan G 7893
As per: 01.12.2012
Page 2
5. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead with plug
V/Hz
kW
A
mm²
m
AC 230/50
6.7
1 × 30
3 × 4
2.1
Voltage
Voltage
Voltage
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
6. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead with plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead with plug
7. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead with plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead with plug
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
convertible
3N AC 400/50
9.2
3 × 15/16
5 × 2.5
1.7
3N AC 400-415/50
9.2-9.9
3 × 15
5 × 2.5
2.1
AC 230-240/50
6.7-7.2
1 × 30
3 × 6
2.1
AC 230-240/50
6.7-7.2
1 × 30
3 × 6
2.1
3N AC 400-415/50
9.2-9.9
3 × 15
5 × 2.5
2.1
Voltage
Voltage
8. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead without plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead without plug
9. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead without plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead without plug
10. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
V/Hz
kW
A
AWG
m
V/Hz
kW
A
AWG
m
convertible
V/Hz
kW
A
AWG
m
V/Hz
kW
A
AWG
m
convertible
V/Hz
kW
A
mm²
m
3 AC 208/60
6.0
3 × 20
4 × 12
1.9
AC 208/60
6.0
2 × 30
3 × 10
1.9
AC 208/60
6.0
2 × 30
3 × 10
1.9
3 AC 208/60
6.0
3 × 20
4 × 12
1.9
3 AC 200/50
5.7
3 × 20
5 × 2.5
2.3
Voltage
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
Installation plan G 7893
As per: 01.12.2012
Page 3
V/Hz
kW
A
mm²
m
convertible
AC 200/50
5,7
2 × 30
3 × 4
2.1
11. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
V/Hz
kW
A
mm²
m
3 AC 200/60
5.7
3 × 20
5 × 2.5
2.3
Voltage
Voltage
Voltage
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
12. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
13. Voltage (as supplied)
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
AC 200/60
5.7
2 × 30
3 × 4
2.1
3N AC 380/60
6.7
3 × 16
5 × 2.5
2.3
3 AC 220/60
6.7
3 × 20
5 × 2.5
2.3
AC 220/60
4.7
1 × 25
3 × 4
2.1
3 AC 220/60
6.7
3 × 20
5 × 2.5
2.3
Voltage
Voltage
Plug and socket connection recommended to facilitate
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
Rated load
Fuse rating
Min. cable cross-section
Length of supply lead (H05(07)RN-F) without
plug
electrical safety tests. Socket must be accessible after
installation.
On hard-wired machines, a multi-pole circuit breaker with a
minimum contact gap of 3 mm must be provided on site.
The use of an earth leakage circuit breaker (ELCB) is
strongly recommended.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
V/Hz
kW
A
mm²
m
convertible
V/Hz
kW
A
mm²
m
convertible
3N AC 380/60
6.7
3 × 16
5 × 2.5
2.3
AC 220/60
4.7
1 × 25
3 × 4
2.1
Installation plan G 7893
As per: 01.12.2012
Page 4