Miele G 7881 Installation diagram

Installationsplan / Installation plan

Installatietekening

Plano de instalación

Asennusohje

Plan d`installation

Plano de instalação

Installasjonsplan

Pianta di installazione

Σχέδιο εγκατάστασης

Installationsplan

CA

G 7881

Materialnummer

/

Mat. no.

 

7851870

Änderungsstand

/

Version

 

00

Änderungsnr.

/

Alteration number

 

A11647

Datum Zeichnung

/

Drawing Date

 

01.05.2010

Datum Legende

/

Legend Date

 

01.05.2010

Freigabe

/

Approval

Name:

Götza

Installationsplan G 7881

 

Stand: 01.05.2010

Seite 1

Technical Datasheet

Thermal disinfector

G 7881

 

 

Legend:

Circled, bold-type abbreviations:

 

Connection required

GB

Abbreviations surrounded by broken circle: Connection optional

Electrical

1. Voltage (as supplied)

connection

Rated load

 

Fuse rating

 

Min. cable cross-section

 

Length of supply lead (H05(07)RN-F) with plug

 

Voltage

 

Rated load

 

Absicherung

 

Kabelquerschnitt mindestens

 

Länge Anschlusskabel (H05(07)RN-F) mit

 

Stecker

 

Voltage

 

Rated load

 

Fuse rating

 

Min. cable cross-section

 

Length of supply lead (H05(07)RN-F) with plug

 

Country variations:

 

 

2. Voltage (as supplied)

 

 

Rated load

 

Fuse rating

 

Min. cable cross-section

 

Length of supply lead (H05(07)RN-F) without plug

 

Voltage

 

Rated load

 

Fuse rating

 

Min. cable cross-section

 

Length of supply lead (H05(07)RN-F) without plug

 

Voltage

 

Rated load

 

Fuse rating

 

Min. cable cross-section

 

Length of supply lead (H05(07)RN-F) without plug

 

 

<![if ! IE]>

<![endif]>convertible convertible

<![if ! IE]>

<![endif]>convertible convertible

V/Hz

3N AC 400/50

kW

9.7

A3 x 16

mm²

5 x 2.5

m1.7

V/Hz

2N AC 400/50

kW

6.7

A2 x 16

mm²

5 x 2.5

m1.7

V/Hz

AC 230/50

kW

3.7

A1 x 16

mm²

5 x 2.5

m1.7

V/Hz

3N AC 400/50

kW

7.3

A3 x 16

mm²

5 x 2.5

m1.7

V/Hz

3 AC 230/50

kW

7.3

A3 x 20

mm²

5 x 2.5

m1.7

V/Hz

AC 230/50

kW

5.1

A1 x 25

mm²

3 x 4.0

m2.1

Installationsplan G 7881

 

Stand: 01.05.2010

Seite 2

 

 

3. Voltage (as supplied)

 

V/Hz

3 AC 230/50

 

 

Rated load

 

kW

7.3

 

 

Fuse rating

 

A

3 x 20

 

 

Min. cable cross-section

 

mm²

5 x 2.5

 

 

Length of supply lead (H05(07)RN-F) without plug

 

m

1.7

 

 

Voltage

<![if ! IE]>

<![endif]>convertible

V/Hz

3N AC 400/50

 

 

 

 

Rated load

kW

7.3

 

 

 

 

 

Fuse rating

 

A

3 x 16

 

 

Min. cable cross-section

 

mm²

5 x 2.5

 

 

Length of supply lead (H05(07)RN-F) without plug

 

m

1.7

 

 

Voltage

<![if ! IE]>

<![endif]>convertible

V/Hz

AC 230/50

 

 

 

 

Rated load

kW

5.1

 

 

 

 

 

Fuse rating

 

A

1 x 25

 

 

Min. cable cross-section

 

mm²

3 x 4.0

 

 

Length of supply lead (H05(07)RN-F) without plug

 

m

2.1

 

 

 

 

 

 

 

 

4. Voltage (as supplied)

 

V/Hz

3N AC 400/50

 

 

Rated load

 

kW

9.2

 

 

Fuse rating (integrated in plug)

 

A

3 x 15/16

 

 

Min. cable cross-section

 

mm²

5 x 2.5

 

 

Length of supply lead (H05(07)RN-F) with plug

 

m

1.7

 

 

Voltage

<![if ! IE]>

<![endif]>convertible

V/Hz

AC 230/50

 

 

 

 

Rated load

kW

6.7

 

 

 

 

 

Fuse rating

 

A

1 x 30

 

 

Min. cable cross-section

 

mm²

3 x 4.0

 

 

Length of supply lead (H05(07)RN-F) without plug

 

m

2.1

 

 

 

 

 

 

 

 

5. Voltage (as supplied)

 

V/Hz

AC 230/50

 

 

Rated load

 

kW

6.7

 

 

Fuse rating (integrated in plug)

 

A

1 x 30

 

 

Min. cable cross-section

 

mm²

3 x 4.0

 

 

Length of supply lead (H05(07)RN-F) with plug

 

m

2.1

 

 

Voltage

<![if ! IE]>

<![endif]>convertible

V/Hz

3N AC 400/50

 

 

 

 

Rated load

kW

9.2

 

 

 

 

 

Fuse rating

 

A

3 x 15/16

 

 

Min. cable cross-section

 

mm²

5 x 2.5

 

 

Length of supply lead (H05(07)RN-F) without plug

 

m

1.7

 

 

 

 

 

 

 

 

6. Voltage (as supplied)

 

V/Hz

AC 230/50

 

 

Rated load

 

kW

2.9

 

 

Fuse rating (integrated in plug)

 

A

1 x 13

 

 

Min. cable cross-section

 

mm²

1 x 1.5

 

 

Length of supply lead (H05(07)RN-F) with plug

 

m

2.1

 

 

 

 

 

 

 

 

7. Voltage (as supplied)

 

V/Hz

3N AC 400-415/50

 

 

Rated load

 

kW

9.2-9.9

 

 

Fuse rating

 

A

3 x 15

 

 

Min. cable cross-section

 

mm²

3 x 2.5

 

 

Length of supply lead with plug

 

m

2.1

 

 

Voltage

<![if ! IE]>

<![endif]>convertible

V/Hz

AC 230-240/50

 

 

 

 

Rated load

kW

6.7-7.2

 

 

 

 

 

Fuse rating

 

A

1 x 30

 

 

Min. cable cross-section

 

mm²

3 x 4.0

 

 

Length of supply lead with plug

 

m

2.1

 

 

 

 

 

 

 

 

8. Voltage (as supplied)

 

V/Hz

AC 230-240/50

 

 

Rated load

 

kW

6.7-7.2

 

 

Fuse rating

 

A

1 x 30

 

 

Min. cable cross-section

 

mm²

3 x 4.0

 

 

Length of supply lead with plug

 

m

2.1

 

 

Voltage

<![if ! IE]>

<![endif]>convertible

V/Hz

3N AC 400-415/50

 

 

 

 

Rated load

kW

9.2-9.9

 

 

 

 

 

Fuse rating

 

A

3 x 15

 

 

Min. cable cross-section

 

mm²

3 x 2.5

 

 

Length of supply lead with plug

 

m

2.1

 

 

 

 

 

 

Installationsplan G 7881

 

Stand: 01.05.2010

Seite 3

Miele G 7881 Installation diagram

9. Voltage (as supplied) Rated load

Fuse rating

Min. cable cross-section Length of supply lead with plug

Voltage

Rated load

Fuse rating

Min. cable cross-section

Length of supply lead with plug

10. Voltage (as supplied) Rated load

Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

Voltage Rated load Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

11. Voltage (as supplied) Rated load

Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

Voltage Rated load Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

12. Voltage (as supplied) Rated load

Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

Voltage Rated load Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

Voltage Rated load Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

13. Voltage Rated load Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

Voltage (as supplied) Rated load

Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

Voltage Rated load Fuse rating

Min. cable cross-section

Length of supply lead (H05(07)RN-F) without plug

<![if ! IE]>

<![endif]>convertible

<![if ! IE]>

<![endif]>convertible

<![if ! IE]>

<![endif]>convertible

<![if ! IE]>

<![endif]>convertible convertible

<![if ! IE]>

<![endif]>convertible convertible

V/Hz

2 AC 208/60

kW

6.0

A2 x 30

AWG

3 x 10

m1.9

V/Hz

3 AC 208/60

kW

6.0

A3 x 20

AWG

4 x 12

m1.9

V/Hz

3 AC 200/50

kW

5.7

A3 x 20

mm²

5 x 2.5

m2.3

V/Hz

AC 200/50

kW

5.7

A2 x 30

mm²

3 x 4

m2.1

V/Hz

3 AC 200/60

kW

5.7

A3 x 20

mm²

5 x 2.5

m2.3

V/Hz

AC 200/60

kW

5.7

A2 x 30

mm²

3 x 4

m2.1

V/Hz

3N AC 380/60

kW

6.7

A3 x 16

mm²

5 x 2.5

m2.3

V/Hz

3 AC 220/60

kW

6.7

A3 x 20

mm²

5 x 2.5

m2.3

V/Hz

AC 220/60

kW

4.7

A1 x 25

mm²

3 x 4

m2.1

V/Hz

3 AC 220/60

kW

6.7

A3 x 20

mm²

5 x 2.5

m2.3

V/Hz

3N AC 380/60

kW

6.7

A3 x 16

mm²

5 x 2.5

m2.3

V/Hz

AC 220/60

kW

4.7

A1 x 25

mm²

3 x 4

m2.1

Installationsplan G 7881

 

Stand: 01.05.2010

Seite 4

Loading...