Voltage V/Hz 3N AC 230/50
Rated load kW 7.8
Fuse rating A 3 × 20
Connection cable, min. cross-section mm² 5 × 2,5
3. Voltage (as supplied)
Rated load kW 7.8
Fuse rating A 3 × 20
Connection cable, min. cross-section mm² 5 × 2.5
Rated load kW 10.2
Fuse rating A3 × 16
1. Voltage
Length of supply lead (H05(07)RN-F) with plug m 1.7
Length of supply lead (H05(07)RN-F) with plug
Length of supply lead (H05(07)RN-F) with plug m 1.7
V/Hz 3N AC 400/50
V/Hz 3N AC 400/50
convertible
m 1.7
V/Hz 3N AC 230/50
Voltage V/Hz 3N AC 400/50
Rated load kW 7.8
Fuse rating A 3 × 16
Connection cable, min. cross-section mm² 5 × 2.5
4. Voltage
Rated load kW 8.7
Fuse (integrated into plug) A3 × 15/16
Connection cable, min. cross-section mm² 5 × 2.5
5. Voltage
Rated load kW 8.7-9.3
Fuse rating A3 × 15
Connection cable, min. cross-section mm² 5 × 2.5
Length of supply lead (H05(07)RN-F) with plug
Length of supply lead with plug m 1.7
Length of supply lead without plug m 1.7
m 1.7
convertible
V/Hz 3N AC 400/50
V/Hz 3N AC 400-415/50
Installationsplan G 7836 CD
Stand: 01.11.2004
Seite 5
Page 6
6. Voltage
Rated load kW 6.6
Fuse rating A3 × 20
Connection cable, min. cross-section AWG 4 × 12
7. Voltage
Rated load kW 6.2
Fuse rating A3 × 20
Connection cable, min. cross-section mm² 5 × 2.5
8. Voltage
Rated load kW 6.2
Fuse rating A3 × 20
Connection cable, min. cross-section mm² 5 × 2.5
9. Voltage (as supplied)
Rated load kW 7.2
Connection cable, min. cross-section mm² 5 × 2.5
Length of supply lead (H05(07)RN-F) without plugm 2.3
Voltage V/Hz 3 AC 220/60
Rated load kW 7.2
Fuse rating A 3 × 20
Connection cable, min. cross-section mm² 5 × 2.5
Length of supply lead (H05(07)RN-F) without plug
10. Voltage (as supplied)
Rated load kW 7.2
Connection cable, min. cross-section mm² 5 × 2.5
Length of supply lead (H05(07)RN-F) without plugm 2.3
Length of supply lead without plug m 1.9
Length of supply lead (H05(07)RN-F) without plugm 2.3
Length of supply lead (H05(07)RN-F) without plugm 2.3
Fuse rating A3 × 16
Fuse rating A 3 × 20
V/Hz 3 AC 208/60
V/Hz 3 AC 200/50
V/Hz 3 AC 200/60
V/Hz 3N AC 380/60
convertible
m 2.3
V/Hz 3 AC 220/60
Voltage V/Hz 3N AC 380/60
Rated load kW 7.2
Fuse rating A 3 × 16
Connection cable, min. cross-section mm² 5 × 2.5
Length of supply lead (H05(07)RN-F) with plug
Plug and socket connection recommended to facilitate
electrical safety tests. Socket must be accessible after
installation.
Connection to electrical supply should be in accordance with
valid regulations and safety standards. Observe correct phase
sequence (clockwise). Supply lead should not be in direct
contact with any source of heat.
The use of a current-operated ELCB is recommended!
In the case of a run of several units, the connections for the
middle units should be extended to the side. This may require
substituting a longer supply lead. Replacement supply leads
must be provided on site and available at the time of
commissioning.
m 2.3
convertible
Installationsplan G 7836 CD
Stand: 01.11.2004
Seite 6
Page 7
Cold water Two cold water connections required on models with steam
Max. temperature °C 20
Max. water hardness °dH 60
Min. flow pressure kPa 250
Max. pressure kPa 1000
Throughput l/min 10
On-site connection thread according to DIN 44 991 Inch 3/4" external thread
Length of connection hose (supplied) mm 1500
Length of steam condenser inlet hose (supplied with DK
DVGW certification Direct connection without fuse box permissible. Water connection Australia:
Hot water Max. temperature °C 70
Max. water hardness °dH 60
Min. flow pressure kPa 250
Max. pressure kPa 1000
Throughput l/min 10
On-site connection thread according to DIN 44 991 Inch 3/4" external thread
Length of connection hose (supplied) mm 1500
DVGW certification Direct connection without fuse box permissible. Water connection Australia:
condenser (DK).
Second cold water inlet hose can be connected using Y-piece
supplied.
version)
To prevent back-syphonage, the water connection must be
via an approved Dual-Check-Valve supplied with the
machine.
To prevent back-syphonage, the water connection must be
via an approved Dual-Check-Valve supplied with the
machine.
(USA: 11.5 NH)
mm 1500
(USA: 11.5 NH)
Demineralised
water
Min. flow pressure kPa 250
Min. flow pressure with extended fill time kPa 100
Max. pressure kPa 1000
Throughput l/min 10
Connection thread (on site) Inch ¾ external
Length of connection hose (supplied) mm 1500
Version with demin. water feed pump (ADP): Min. flow pressure kPa 5
Max. pressure kPa 30
Machine-side connection (ext. dia. × wall thickness) mm 6 × 30
Waste water Two drain hoses supply with DK version.
Drain hose (Int. dia. × wall thickness × l) Drain pump (supplied) mm 22 × 6 × 1500
Steam condenser (supplied with DK version) mm 22 × 6 × 1500
Drain pump head height from floor level, max. m 1.0
Max. transient throughput – Drain hose l/min 50
On-site hose connector (Ext. dia. × l) Drain pump mm 22 × 30
Steam condenser (DK version) mm 22 × 30
Machine data Height incl. lid mm 1175
Width mm 900
Depth mm 700
Net weight kg 190
Dynamic floor load N 3000
Min. transport width incl. pallet mm 800
Min. transport height incl. pallet mm 1400
Standard version:
(USA: 11.5 NH)
Installation should only be carried out by authorised fitters in accordance with valid regulations!