This machine conforms to current
safety requirements. However,
inappropriate use can lead to
personal injury and property
damage. Read the operating
instructions carefully before using
this machine.
The manufacturer cannot be held
responsible for damage caused by
non-observance of these Important
Safety Instructions.
Use
This machine is designed for
commercial use and for
specialized applications only, as
described in these Operating
Instructions. Do not use for purposes
other than those for which it was
designed, as this could be dangerous.
Miele is not responsible for damages
caused by improper use.
The installation of this unit in non
stationary locations (e.g. ships)
must be performed by a qualified
installer or service agency in strict
accordance with national and local
safety regulations and standards.
Please pay attention to the following
notes to maintain safe procedures.
The machine should be
commissioned and maintained only
by a Miele Service Technician. Repairs
by unqualified persons could be
dangerous.
Do not install the machine in an
area where a danger of explosion
or freezing may be present.
Be certain this appliance is
properly installed and grounded by
an authorized technician. To guarantee
the electrical safety of this appliance,
continuity must exist between the
appliance and an effective grounding
system. It is imperative that this basic
safety requirement be met. If there is
any doubt, have the electrical system
checked by a qualified technician. The
manufacturer cannot be held
responsible for damage or injury
caused by the lack, or inadequacy, of
an effective grounding system
(e.g. electric shock).
A damaged machine is dangerous.
Turn off the machine immediately at
the power switch and call the Miele
Service Department.
Personnel operating the machine
should be trained regularly.
Children and untrained personnel must
not be allowed access to the machine
or its controls.
5
IMPORTANT SAFETY INSTRUCTIONS
Take care when handling liquids
such as detergents, neutralizing
agents, wetting agents and rinse aids.
These may contain irritant or corrosive
ingredients, acids or alkalis. Never use
any organic solvents, as the danger of
explosion exists. Wear protective
gloves and goggles. The
manufacturer’s safety conditions must
be observed at all times.
The water in the machine must not
be used as drinking water.
Be careful when sorting items with
sharp pointed ends. Position them
in the machine so that you do not hurt
yourself or create a danger for others.
When using this machine regard
the high temperatures and be
especially careful not to scald or burn
yourself. When opening the door
bypassing the electrical lock, a danger
of burning, scalding and corrosion
exist. Let mobile units, inserts and
cleaned items cool before touching
them. Any water which may remain in
containers will be very hot and must be
emptied into the wash cabinet.
After drying with the TA drying unit
open the door to allow the items
and inserts to cool.
Do not touch the heating elements
(under the wide area filter) during
or directly after the end of a program,
you could burn yourself. They remain
hot for some time after the program
end.
If the boiler has been programmed
to "BOILER READY", be particularly
careful of hot water and steam when
opening the door. Danger of burning or
scalding. The water inlet pipe to the
wash cabinet is located, as viewed
from the unclean side, underneath the
basket runner on the left hand side.
Steam heating is permissible up to
a pressure of 145 psi. This
corresponds to a water steam
temperature of 354°F (179 °C).
Never clean the machine near or
with a water or high pressure hose.
Before servicing, disconnect the
power supply by either removing
the fuse, unplugging the unit or
manually "tripping" the circuit breaker.
,
Mount on non-combustible floors
only!
6
IMPORTANT SAFETY INSTRUCTIONS
The following points should be
observed to assist in maintaining
quality standards, for critical lab
glassware, to protect patients, and to
avoid damage to the loads being
cleaned.
Use only Miele approved cleaning
agents with this machine. Use of
unsuitable cleaning agents could
adversely affect the components of the
machine. Damages resulting from using
unsuitable cleaning agents are not
covered by the warranty.
Pre-treating (e.g. with cleaning
agents), certain soiling and
cleaning agents with a chemical
interaction, can cause foam. For
pre-treatment and/or cleaning only use
low-sudsing detergents which have
been approved by Miele. Suds can
have an adverse effect on the operation
of the machine.
After START has been pressed the
program must not be interrupted
by pressing the I-0 button. A program
should not be interrupted since the
result may be effected. Otherwise the
program must be repeated.
When a chemical additive is
recommended, the manufacturer of
the machine takes no responsibility for
the effect of the chemical on the items
being cleaned.
The machine must only be
operated with water and the
recommended cleaning agents.
Organic solvents must not be used in
the machine as there is the danger,
under certain circumstances, of
explosion and damage to rubber and
synthetic materials. Follow the dosage
recommendations of the cleaning
agent’s manufacturer.
In critical applications where very
high requirements have to be met,
it is strongly recommended that all the
relevant factors for the process, such
as cleaning agent, quality of water, etc.
are discussed with the Miele
Applications Specialists.
If the cleaning result is subject to
particularly stringent requirements
(e.g. chemical analysis, specialized
processes), a regular quality control
test should be carried out by the user to
ensure that the required standards of
cleanliness are being achieved.
The cleaning standard in the
routine use must be verified by the
user. The process should be checked
regularly using thermoelectric and
documented results.
7
IMPORTANT SAFETY INSTRUCTIONS
The mobile units and special
inserts should only be used for
their specific application.
Empty any containers or utensils
before arranging them in the
machine.
Do not allow any remains of acids,
solvents or corroding ferrous
material, and in particular hydrochloric
acid or chloride solutions to get into the
wash cabinet. Similarly avoid any
materials with a corrosive effect. The
presence in compounds of any solvents
should be minimal, (especially those in
hazard class A1).
To avoid any corrosion damage
ensure that solutions or steam
containing hydrochloric acid do not
come in contact with the stainless steel
casing of the machine.
Please follow the installation advice
in these instructions and the
separate Installation Instructions.
Disposal of an old appliance
When discarding a lab washer,
disconnect it from the power
supply and cut off the power cord.
The old appliance may be
contaminated by blood or other body
fluids and must be disinfected before
disposal.
For environmental and safety reasons
ensure the machine is completely
drained of any residual water and
cleaning agent. (Observe safety
regulations and wear safety goggles
and gloves). Make the door lock
inoperative or remove the door
completely, so that children cannot
accidentally shut themselves in. Make
appropriate arrangements for the safe
disposal of the machine.
Machines with a tank system: remove
the water from the tank before
disposing the machine.
Using accessories
Only specific additional equipment
made by Miele should be
connected to this machine. Consult a
Miele Application Specialist on the type
and application of such equipment.
Only Miele mobile units, modules
and inserts should be used. If
equipment from another manufacturer
is used, Miele cannot ensure the
cleaning and disinfection results.
Damage or injury caused by this are
excluded from the warranty.
8
SAVE THESE
INSTRUCTIONS
Description of the machine
The Miele G 7827/G 7828 Large
Capacity Glassware Washer is
designed for high-throughput,
centralized wash areas. This unit is
ideal for cleaning both large volumes of
small items, and difficult to clean large
items.
Optional peripheric machines
Drying unit (TA)
–
Steam condensor (DK)
–
Report printer (PRT)
–
9
Description of the machine
Electronic controls
10
Description of the machine
a Display
with screen saver
The background light turns off
automatically after 15 minutes.
Press any key to turn the background
^
light on again.
b On/Off button (I-0)
c Cursor left 1
moves the cursor to the left:
– to the previous menu
– to the previous parameter
– to the previous input position
d Cursor right 2
moves the cursor to the right:
– to the next menu
– to the next parameter
– to the next input position
e Minus button 3
– program selection for programs
over 24
– scrolling back pagewise in menus
– entering numbers and letters
– changing default settings,
e.g. service parameter
g Door button 5
h Start button 6
– Starting a program
– Activating insert mode
– Confirming settings
– Confirming menu points,
to get to the respective submenu
i Stop button 7
– Canceling a program
– Leaving the input screen
without saving
– Leaving a menu
j Optical interface 8
(for service technician)
k Program selector
Selecting programs 1-23
f Plus button 4
– program selection for programs
over 24
– scrolling forward pagewise in
menus
– entering numbers and letters
– changing default settings,
e.g. service parameter
11
Description of the machine
Unclean side
a Drying unit (TA)
b Steam condensor (DK)
behind top housing (Optional)
c Electronic circuit board "Profitronic"
(see "Programming manual")
d Controls
12
e Power switch (with "Emergency
cut-off" function for Service)
f Lift door (closed)
g Adapter for the "Miele transfer" cart
h Service panel
Unclean side
Description of the machine
a Lift door (open)
b Filter combination
c Containers for dosage system DOS 1 - DOS 4
13
Description of the machine
Clean side (G 7828 only )
a "Door" button
b Lift door (closed)
c Printer (optional)
G 7827 on the unclean side
d Service panel
with adapter for "Miele transfer" cart
14
Opening and closing the lift door
The lift door can only be opened when:
the lab glassware washer is
–
connected to the electrical supply,
the red ("emergency cut off") switch
–
is in the I-ON position,
the I-0 On-Off button is pressed in,
–
and
no program is running.
–
The lift door on the clean side (G 7828)
can only be opened when:
– DESIN (disinfection) programs have
been correctly completed,
or
– the Door interlock has been
activated, i.e. DOOR MECH. has
been set to one of the following
parameters:
- INTERLOCK,
- DOOR CLEAN+INTERLOCK,
- DOOR UNCL.+INT.LOCK.
(see "Machine function - Door
mechanism..." in the Programming
manual).
To open the lift door
Press the 5 door button. The lift door
^
rises.
Do not touch the heating
,
elements (under the wide area filter)
during or directly after the end of a
program, you could burn yourself.
If the boiler has been programmed
to "BOILER READY", be particularly
careful of hot water and steam when
opening the door. Danger of burning
or scalding. The water inlet pipe to
the wash cabinet is located, as
viewed from the unclean side,
underneath the basket runner on the
left hand side.
To close the lift door
^ Press the 5 door button. The lift door
lowers.
15
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.