K
M
Room Air Conditioner
SERVICE MANUAL
MODEL : LS-B0760CM/B0760HM
LS-B0960CM/B0960HM
LS-B0962CM/B0962HM
LS-B0962CD/B0962HD
LS-B0960CD/B0960HD
LS-C1260CM/C1260HM
LS-C1260CD/C1260HD
LS-C1120CM/C1420CM
LS-C1420CN
CAUTION
BEFORE SERVICING THE UNIT,
READ THE "SAFETY PRECAUTIONS" IN THIS MANUAL.
K
M
Contents
Functions...................................................................................................................................... 3 Product Specifications (Cooling Only) ...................................................................................... 5 Product Specifications (Cooling & Heating).............................................................................. 6 Dimensions................................................................................................................................... 7 Maximum Length of Pipe and Freon Extra Charge................................................................... 9 Refrigeration Cycle Diagram..................................................................................................... 10 Wiring Diagram .......................................................................................................................... 11 Operation Details ....................................................................................................................... 13 Display Function ........................................................................................................................ 20 Self-diagnosis Function ............................................................................................................ 20 Installation .................................................................................................................................. 21 Operation .................................................................................................................................... 39 Disassembly of the parts(Indoor Unit) ..................................................................................... 41 2-way, 3-way Valve ..................................................................................................................... 44 Cycle Troubleshooting Guide ................................................................................................... 51 Electronic Parts Troubleshooting Guide.................................................................................. 52 Electronic Control Device ......................................................................................................... 56 Schematic Diagram.................................................................................................................... 59 Exploded View & Replacement Parts List ............................................................................... 61
- 2 -
Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
• Room temperature sensor(THERMISTOR).
Room temperature control
•Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
•Indoor fan is delayed for 5 seconds at the starting.
Time Delay Safety Control
• Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
• High, Med, Low, Chaos or Auto
Operation indication Lamps (LED)
--- Lights up in Operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode or Hot Start Mode (only Heating Model)
OUT
DOOR --- Lights during in compressor running (for Cooling Model)
Soft Dry Operation Mode
• Intermittent operation of fan at low speed
Sleep Mode Auto Control
•The fan is switched to low(Cooling), med(Heating) speed.
•The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Auto Air Control by CHAOS Logic
•The fan is switched to intermittent or irregular operation.
•The fan speed is automatically switched from high to low speed.
Airflow Direction Control
•The louver can be set at the desired position or swing up and down, right and left (not on all models) automatically.
AUTO Wind
• The fan speed is automatically switched from high to low speed.
Deice(defrost) control(Heating)
•Both the indoor and outdoor fan stops during deicing.
•Hot start after deice ends.
Hot-start Control(Heating)
•The indoor fan stops until the evaporator piping temperature will be reached at 28°C.
- 3 -
Remote Controller
Operation ON/OFF
Operation Mode Selection
Cooling Operation Mode ( |
) |
Auto Operation Mode ( |
) |
Soft Dry Operation Mode ( |
) |
Heating Operation Mode ( |
) |
(Cooling model only) (Heatling model only) |
|
|
|
Fan Speed Selection
(Low) (Med)
Room, Temperature Display
|
: High: 39°C |
|
LOW : 11°C |
|
Temperature Setting |
|
|
||
TEMPERATURE |
LOW |
HIGH |
Cooling |
Down to 18°C |
|
|
|
||
|
|
|
Up to 30°C, |
|
|
|
|
|
Setting the Time or timer
Timer Selection
(High) |
(AUTO WIND) |
|
(CHAOS) |
Down to 16°C
Heating
Up to 30°C,
: OFF, ON, OFF ON
Timer Setting
Timer Cancel
: Cancel Sleep Mode, Timer ON or Timer OFF
Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control
Fan Operation Mode
: Fan Operates without cooling or heating.
Reset
- 4 -
Product Specifications (Cooling Only)
|
Model Name |
LS-B0760CM |
LS-B0960CD LS-B0962CD |
LS-C1120CM |
LS-C1260CD LS-C1420CM |
||||
|
|
|
|||||||
Item |
Unit |
|
LS-B0960CM LS-B0962CM |
|
LS-C1260CM |
LS-C1420CN |
|||
|
|
|
|
|
|
||||
Cooling Capacity |
BTU/h(kcal/h) |
7,300(1,840) |
8,700(2,190) |
8,700(2,190) |
11,000(2,770) |
12,000(3,020) |
14,000(3,528) |
||
Moisture Removal |
ℓ/h |
1.0 |
1.2 |
1.2 |
1.2 |
1.7 |
1.7 |
||
Power Source |
|
Ø, V, Hz |
1Ø, 220-240V, 50Hz |
1Ø, 220V~,60Hz |
1Ø, 220-240V,50Hz |
1Ø, 220V~,60Hz |
|||
Air Circulation |
Indoor |
m3/min |
4.85 |
5.3 |
5.3 |
8.5 |
10.2 |
9.5 |
|
Outdoor |
25 |
25 |
25 |
25 |
25 |
25 |
|||
|
|
||||||||
Noise Level |
Indoor |
dB(A) |
36±3 |
39±3 |
38±3 |
39±3 |
41±3 |
41±3 |
|
Outdoor |
47±3 |
49±3 |
49±3 |
49±3 |
50±3 |
50±3 |
|||
|
|
||||||||
Input |
|
W |
755 |
920 |
920 |
1,050 |
1,140 |
1,270 |
|
Runnig Current |
|
A |
3.2 |
4.0 |
4.0 |
4.9 |
5.0 |
5.9 |
|
E.E.R. |
|
BTU/h-W |
9.7 |
9.5 |
9.5 |
10.5 |
10.5 |
11 |
|
Motor Output |
Indoor |
W |
7 |
10 |
10 |
10 |
15 |
15 |
|
Outdoor |
25 |
25 |
25 |
25 |
25 |
25 |
|||
|
|
||||||||
Dimensions |
Indoor |
mm |
810 x 220.5 x 152 |
900 x 290 x 183 |
|||||
(W x H x D) |
Outdoor |
660 x 540 x 260 |
|
801 x 555 x 262 |
|||||
|
|
||||||||
Net. Weight |
Indoor |
kg |
6.5 |
6.5 |
6.5 |
10 |
10 |
10 |
|
Outdoor |
27 |
27 |
27 |
33 |
33 |
35 |
|||
|
|
||||||||
Refrigerant(R-22) |
g |
540 |
670 |
690 |
1,080 |
840 |
980 |
||
Airflow Direction Control (Up & Down) |
O |
O |
O |
O |
O |
O |
|||
Remocon type |
|
|
|
|
L.C.D Wireless |
|
|
||
Service valve |
|
Liquid |
1/4"(6.35) |
|
1/4"(6.35) |
|
|||
|
|
|
|
|
|
|
|
||
|
|
Gas |
3 /8"(9.52) |
3/8"(9.52) |
|
1/2"(12.7) |
|
||
Sleeping Operation |
|
O |
O |
O |
O |
O |
O |
||
Drain Hose |
|
|
O |
O |
O |
O |
O |
||
Connecting Cable |
|
|
|
1.0mm2 |
|
|
|||
Power Cord |
|
|
|
|
1.0mm2 |
|
|
- 5 -
Product Specifications (Cooling & Heating)
|
Model Name |
LS-B0760HM |
LS-B0960HD |
LS-B0962HD |
LS-C1260HD |
|||
|
|
|
||||||
Item |
Unit |
LS-B0960HM |
LS-B0962HM |
LS-C1260HM |
||||
|
|
|||||||
Cooling Capacity |
|
BTU/h(kcal/h) |
7,000(1,764) |
8,500(2,142) |
8,500(2,142) |
12,000(3,020) |
||
Heating Capacity |
|
7,500(1,890) |
9,500(2,394) |
9,500(2,394) |
12,500(3,150) |
|||
|
|
|||||||
Moisture Removal |
ℓ/h |
1.0 |
|
1.2 |
1.2 |
1.7 |
||
Power Source |
|
Ø, V, Hz |
|
|
1Ø, 220-240V, 50Hz |
|
||
Air Circulation |
|
m3/min |
Indoor |
4.85 |
5.3 |
5.6 |
10.2 |
|
|
Outdoor |
25 |
25 |
25 |
25 |
|||
|
|
|
||||||
Noise Level |
|
dB(A) |
Indoor |
36±3 |
39±3 |
40±1 |
41±3 |
|
|
Outdoor |
47±3 |
49±3 |
50±1 |
51±3 |
|||
|
|
|
||||||
Input |
Cooling |
W |
760 |
|
940 |
895 |
1,250 |
|
Heating |
780 |
|
1,030 |
950 |
1,100 |
|||
|
|
|
||||||
Runnig Current |
Cooling |
A |
3.2 |
|
4.1 |
3.8 |
5.5 |
|
Heating |
3.3 |
|
4.4 |
4.1 |
4.8 |
|||
|
|
|
||||||
E.E.R. |
Cooling |
BTU/h·W |
9.2 |
|
9.0 |
9.5 |
9.6 |
|
C.O.P |
Heating |
W/W |
2.82 |
|
2.7 |
2.76 |
3.3 |
|
Motor Output |
|
W |
Indoor |
7 |
10 |
10 |
15 |
|
|
Outdoor |
25 |
25 |
25 |
25 |
|||
|
|
|
||||||
Dimensions |
|
mm |
Indoor |
|
810 x 220.5 x 152 |
900 x 290 x 183 |
||
(W x H x D) |
|
Outdoor |
|
660 x 540 x 260 |
810 x 555 x 262 |
|||
|
|
|
||||||
Net. weight |
|
kg |
Indoor |
6.5 |
6.5 |
6.5 |
10 |
|
|
Outdoor |
30 |
30 |
30 |
35 |
|||
|
|
|
||||||
Refrigerant(R-22) |
|
g |
590 |
|
690 |
720 |
810 |
|
Airflow Direction Control (Up & Down) |
O |
|
O |
O |
O |
|||
Remocon Type |
|
|
|
|
L.C.D Wireless |
|
||
Service Valve |
|
|
Liquid |
|
1/4"(6.35) |
|
|
|
|
|
Gas |
|
3/8"(9.52) |
|
1/2"(12.7) |
||
|
|
|
|
|
||||
Sleeping Operation |
|
O |
|
O |
O |
O |
||
Drain Hose |
|
|
O |
|
O |
O |
O |
|
Connecting Cable |
|
|
|
|
1.0mm2 |
|
|
|
Power Cord |
|
|
|
|
1.0mm2 |
|
|
- 6 -
Dimensions
(1) Indoor Unit
(7K, 9K) |
(11K, 12K, 14K) |
D |
D |
H H
Tubing hole cover |
Tubing hole cover |
Tubing hole cover |
50 |
Tubing hole cover |
Hole for piping
Installation plate
2cm
Installation plate
4.5cm
8cm
4cm
Hole for piping
|
MODEL |
7K, 9K BTU |
11K, 12K, 14K BTU |
DIM |
|
Series |
Series |
W |
mm |
810 |
900 |
H |
mm |
220.5 |
290 |
D |
mm |
152 |
183 |
- 7 -
(2) Oudoor Unit (7K, 9K, 11K, 12K, 14K)
W
D |
L1 |
L2
H |
L3 |
L10
|
|
|
|
L9 |
L4 |
L6 |
L5 |
L7 |
L8 |
|
|
|
|
Liquid side 2-way valve
Gas side 3-way valve
|
MODEL |
7K, 9K, 11K BTU Series |
12K, 14K BTU Series |
DIM |
|
||
|
|
|
|
W |
mm |
660 |
801 |
H |
mm |
540 |
555 |
D |
mm |
260 |
262 |
L1 |
mm |
297 |
339 |
L2 |
mm |
18.5 |
37 |
L3 |
mm |
523 |
543.6 |
L4 |
mm |
17 |
11.4 |
L5 |
mm |
447 |
591 |
L6 |
mm |
76.5 |
105 |
L7 |
mm |
76.5 |
105 |
L8 |
mm |
66 |
72.5 |
L9 |
mm |
82 |
86.4 |
L10 |
mm |
77 |
77 |
- 8 -
Maximum Length of Pipe and Freon Extra Charge
Charge amount per 1m
Capacity |
STANDARD |
|
MAXIMUM LENGTH |
Charge amount (g) |
||
|
|
|
|
|||
(Btu/h) |
LENGTH(m) |
|
|
|
|
per 1m |
|
A |
|
B |
|||
|
|
|
|
|
||
|
|
|
|
|
|
|
~7000 |
4 |
|
7 |
|
15 |
20 |
|
|
|
|
|
|
|
~9000 |
4 |
|
7 |
|
15 |
20 |
|
|
|
|
|
|
|
~12000 |
4 |
|
7 |
|
15 |
20 |
|
|
|
|
|
|
|
~18000 |
5 |
|
15 |
|
30(25) |
40 |
|
|
|
|
|
|
|
~24000 |
5 |
|
15 |
|
25 |
40 |
|
|
|
|
|
|
|
Indoor unit
Oil trap
Outdoor unit
*A, B mean indoor unit higher located than outdoor unit
*Capicity is based on standard length and maximum allowance length is the basis of reliability.
*Oil trap should be installed per 10 meters.
* Numerical value in "( )" is for Rotary Comp. model.
- 9 -
Refrigeration Cycle Diagram
INDOOR UNIT |
|
OUTDOOR UNIT |
|
LIQUID SIDE |
CAPILLARY TUBE |
|
|
|
|
2-WAY VALVE |
|
HEAT |
|
|
|
HEAT |
|
EXCHANGE |
|
|
|
EXCHANGE |
|
(EVAPORATOR) |
|
|
|
(CONDENSER) |
|
|
|
|
|
||
|
|
|
GAS SIDE |
|
|
|
3-WAY VALVE |
ACCUMU- |
REVERSING |
|
LATOR |
VALVE |
||
|
|||
|
COMPRESSOR |
COOLING |
|
|
|
HEATING |
- 10 -
Wiring Diagram
(1) 7K, 9K, 11K, 12K, 14K BTU Cooling Only
1. Indoor Unit |
(7K, 9K, 12K) |
(11K, 14K) |
POWER |
|
|
TRANS |
FORCED |
|
|
|
|
OPERATION |
|
|||
|
|
|
FORMER |
SWITCH |
|
|
|
GN/YL |
|
CN-TRANS |
|
|
|
|
|
FAN-CN |
|
|
|
|
1(L) 2(N) |
|
|
|
|
|
|
|
|
|
|
|
N |
|
|
|
BL |
RY-L |
|
|
|
|
|
OR |
RY-M |
|
|
|
MOTOR |
BR |
|
|
|
||
|
|
YL |
RY-H |
|
CN-TH |
|
SH-CAPA 1 |
|
THERMISTOR |
||||
POWER-CN |
|
|
||||
BR BL |
|
|
|
|
|
|
RD BR |
|
|
|
UP/DOWN-CN |
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FUSE T2A |
|
STEP |
|
|
|
|
4 |
3 |
|
MOTOR |
|
|
|
|
|
||
|
|
|
RY-COMP |
|
|
|
|
|
|
|
|
MAIN PCB |
|
|
GN/YN |
|
|
|
ASM |
|
YL BL |
|
|
|
CN-DISP |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
1(L) 2(N) |
PILLAR |
|
DISPLAY PCB ASM |
|||
|
TERMINAL |
|
INDOOR WIRING DIAGRAM
TO OUTDOOR UNIT
TRANS |
FORCED |
OPERATION |
|
FORMER |
SWITCH |
THERMISTOR
MAIN PCB
ASM
PILLAR
TERMINAL
DISPLAY PCB ASM
INDOOR WIRING DIAGRAM
2. Outdoor Unit
COMP
FAN
MOTOR
PILLAR
TERMINAL
TO INDOOR UNIT
OUTDOOR WIRING DIAGRAM
- 11 -
(2) 7K, 9K, 12K BTU Cooling & Heating
1. Indoor Unit
POWER
TRANS |
FORCED |
|
OPERATION |
||
FORMER |
||
SWITCH |
||
|
CN-TRANS
CN-FAN
CN-TH
THERMISTOR
|
UP/DOWNCN- |
STEP |
|
MOTOR |
|
RY-COMP |
|
|
|
|
|
CN-4WAY |
|
|
RY-4WAY |
MAIN PCB |
|
|
ASM |
|
RY-FAN |
CN-DISP |
|
PILLAR TERMINAL
DISPLAY PCB ASM
INDOOR WIRING DIAGRAM
TO OUTDOOR UNIT
2. Outdoor Unit
REVERSING VALVE
FAN MOTOR
PILLAR
TERMINAL
TO INDOOR UNIT
OUTDOOR WIRING DIAGRAM
- 12 -
Operation Details
(1) The function of main control
1. Time Delay Safety Control
•3min... The compressor is ceased for 3minutes to balance the pressure in the refrigeration cycle. (Protection of compressor)
•2sec... The indoor fan is ceased for 2sec. to prevent relay noise.
(Protection of fan relay and micro chip)
• 30sec... The 4-way valve is ceased for 30sec. to prevent the refrigerant-gas abnormal noise when the Heating operation is OFF or switched to the other operation mode.
2. Airflow Direction Control
•This function is to swing the louver up and down automatically and to set it at the desired position.
•The procedure is as the following.
1st ;Press the ON/OFF Button to operate the product.
2nd ;Press the Airflow Direction Control Button to swing the louver up and down automatically. 3rd ;Repress the Airflow Direction Control Button to set the louver as the desired position.
Operating Mode |
Louver Position |
||
|
|
|
|
Cooling |
Start |
2 |
|
|
|
||
Auto. Swing |
1 4 |
||
|
|||
|
|
|
|
Heating |
Start |
5 |
|
|
|
||
Auto. Swing |
3 6 |
||
|
|||
|
|
|
3. Cooling Mode Operation
•When selecting the Cooling ( ) Mode Operation, the unit will operate according to the setting by the remote controller and the operation diagram is as following.
|
|
|
Intake Air temp. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
COMP. ON |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
(SET TEMP.+0.5°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
COMP. OFF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
(SET TEMP.-0.5°C |
|
|
|
|
|
|
More than |
|
|
|
|
|
More than |
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 minutes |
|
|
|
|
|
3 minutes |
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Selectig |
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
Selecting |
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Selectin |
||||||||
INDOOR FAN SPEED |
|
|
|
|
|
|
|
|
|
Low |
|
|
|
|||||||||||||||||
|
|
|
Low |
|
|
|
|
|
|
|||||||||||||||||||||
|
fan speed |
|
|
|
|
fan speed |
|
|
|
|
fan speed |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
OFF |
|
|||||||||||||||||||||||||
|
ON |
|
|
OFF |
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
ON |
ON |
|||||||||||||||||||||
|
COMPRESSOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4. Cooling or Heating Mode with Sleep Mode Auto Operation
•When selecting the Cooling( ) or the Heating( ) combined with the Sleep Mode Auto Operation( ), the operation diagram is as following.
-13 -
• Cooling Mode with the Sleep Mode
The setting temperature will be raised by 1°C 30minutes later and by 2°C 1 hour later.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
|
|
30 minutes |
|
|
30 minutes |
Intake Air temp. |
|
|
|
|
1°C |
COMP. ON |
|
|
|
1°C |
|
|
|
|
|
|
|
(SET TEMP. +0.5°C |
|
|
|
|
|
COMP. OFF |
|
|
|
|
|
(SET TEMP. -0.5°C |
|
More than |
|
More than |
|
|
|
3 minutes |
|
3 minutes |
|
INDOOR FAN SPEED |
Low |
Low |
Low |
Low |
Low |
COMPRESSOR |
ON |
OFF |
ON |
OFF |
ON |
• Heating Mode with the Sleep Mode.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
SETTING TEMP. +3°C |
|
|
|
|
|
|
(COMPRESSOR OFF) |
|
|
|
|
|
|
SETTING TEMP. |
|
|
|
|
|
|
(COMPRESSOR ON) |
|
|
|
|
|
|
INDOOR FAN SPEED |
Med. |
Low or OFF |
Med. |
Low or OFF |
Med. |
Low or OFF |
COMPRESSOR |
ON |
OFF |
ON |
OFF |
ON |
OFF |
- 14 -
5.Auto Operation
•The operation procedure is as following.
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor fan speed |
|
|
|
|
|
|
are automatically decided by Fuzzy rule. |
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
Setting temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Intake-air |
|
|
|
below 21°C |
|
Over |
~ |
|
below |
|
|
|
|
Over 24°C |
||||||
|
|
|
temperature |
|
|
|
|
21°C |
|
24°C |
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation Mode |
|
|
|
Heating |
|
Soft Dry |
|
|
|
|
|
Cooling |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
If initial mode is decided, that mode is continued despite of the room temperature changing. |
|||||||||||||||||||||
|
|
• Auto Operation for Cooling |
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
Operation Condition |
|
|
|
|
Intake-air Temperature |
Setting Temperature |
|
Fan Speed |
Air DirectionControl |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Over 26°C |
|
25°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
Over 24°C~below 26°C |
|
Intake air -1°C |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
When Auto Operation |
|
|
|
Over 22°C~below 24°C |
Intake air -0.5°C |
|
|
|
|
|
|
|
|
||||||||
|
|
initial start |
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
Over 20°C~below 22°C |
Intake air temperature |
|
Controlled by |
|
|
|
1/f rhythm |
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fuzzy logic |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
below 20°C |
|
20°C |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
Over 20°C~below 30°C |
|
Fuzzy control |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
When Switch to Auto |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
below 20°C |
|
20°C |
|
|
|
|
|
|
|
|
|
|||||||
|
Operation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
over 30°C |
|
30°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Intake-Air temp. |
|
|
|
|
Setting Temp. +0.5°C |
|
|
|
|
(Compressor OFF) |
|
|
|
|
Setting Temp. -0.5°C |
|
|
|
|
(Compressor ON) |
|
|
|
|
INDOOR FAN SPEED |
|
Fuzzy Speed |
|
|
COMPRESSOR |
ON |
OFF |
ON |
OFF |
|
|
- 15 - |
|
|
■ Auto Operation for Soft Dry
The Setting temperature will be same that of the current intake-air temperature.
-Compressor ON temperature; Setting temperature +1°C
-Compressor OFF temperature; Setting temperature -0.5°C
■Auto Operation for Heating
Intake Air temp. |
below 20°C |
Over 20°C~below 21°C |
|
|
|
Setting temp. |
20°C |
Intake air temperature +0.5°C |
|
|
|
- 16 -
6.Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as following.
For 9K, 12K Models
Intake Air temp. |
|
|
|
|
|
|
|
|
|
Setting temp. +3°C |
|
|
|
|
|
|
|
|
|
(Compressor OFF) |
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
B |
|
|
A |
|
|
|
|
|
|
|
|
|||
Setting temp. |
|
|
|
|
|
|
|
|
|
(Compressor ON) |
|
|
minimum |
|
minimum |
|
minimum |
|
|
|
|
|
|
|
|
||||
|
|
|
10sec. |
|
10sec. |
|
10sec. |
|
|
|
Hot |
|
|
|
|
|
|
|
|
|
Start |
|
|
|
|
|
|
|
|
INDOOR FAN SPEED |
OFF |
Selecting |
LOW |
OFF |
LOW |
Selecting |
LOW |
OFF |
|
fan speed |
fan speed |
||||||||
|
|
|
|
|
|
|
|||
COMPRESSOR |
|
ON |
|
OFF |
|
ON |
|
OFF |
• A point; The indoor pipe temperature to be 35°C.
The indoor fan operates minimum 10sec. even if falls lower than 35°C.
• B point; The indoor pipe temperature to be 35°C.
The indoor fan operates minimum 10sec. even if falls lower than 35°C.
7. Hot-Start Control
•The indoor fan stops until the evaporator piping temperature will be reached at 28°C. (BY TEMPERATURE)
•The operation diagram is as following.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PIPE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TEMP 28°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60 sec. |
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INDOOR |
|
|
|
|
|
|
|
|
SELECTING |
|||
|
|
|
|
|
|
|
OFF |
|
|
LOW |
|
|||
|
|
FAN SPEED |
|
|
|
|
|
|
FAN SPEED |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
COMPRESSOR |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
ON |
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HOT-START BY TEMPERATURE |
- 17 -
8. Deice Control
•Deicing operation is controlled by timer and sensing the indoor pipe temperature.
•Deicing operation checks the indoor pipe temperature and Intake-air temperature at 25 minutes and 60 minutes on starting of heating operation, and discriminates by temperature difference.
•When the heating operation passed 25 minutes, the temperature ( T1=TE1–TR1) is checked and memorized with checking the indoor pipe temperture (TE1) and the indoor Intake-air temperature (TR1).
•When the heating operation passed 60 minutes, deicing operation checks the indoor pipe temperature (TE2) and the indoor Intake-air temperature (TR2), and checks indoor pipe temperature(TE2), the temperature difference ( T2=TE2–TR2) and the temperature difference Td(= T1– T2) of T1, T2.
If temperature of indoor pipe is below 32°C Deicing function operates at the priority I condition. If temperature of indoor pipe is over 32°C Deicing function operates at the priority II condition.
If the temperature difference ( Td) become more than the option temperature, deicing operation starts.
•At that time, deicing operation time is decided.
•The deicing operation time starts after deicing operation started.
•If deicing operation start, above heating operation time is reset, so if deicing operation is finished, the heating operation time is recounted.
•The deicinig time and the operation diagram are as following.
TEMP °C |
60 minutes |
|
|
|
|
|
|
|
|
|
|
|
|
|
25 mins |
|
|
|
|
25 mins |
|
TE1 |
|
|
|
|
|
|
|
|
|
TE2 |
|
|
|
T1 |
T2 |
T2 |
|
|
T1 |
Pipe Temp. |
|
|
|
|
|
|
Intake Air |
|
|
|
|
Hot |
|
Temp. |
|
|
|
|
|
|
Heating |
|
|
Deicing |
Start |
Heating |
|
|
|
|
||||
COMPRESSOR |
ON |
|
|
ON |
ON |
ON |
4-WAY VALVE |
ON(Heating Operation) |
|
OFF |
ON |
ON |
|
OUTDOOR FAN |
ON |
|
|
OFF |
ON |
ON |
INDOOR FAN |
ON |
|
|
OFF |
|
ON |
DEICE LED |
OFF |
|
|
ON |
|
OFF |
(DEICING DIAGRAM)
Priority I
TE2 |
below 30°C |
|
30~31°C |
|
|
31~32°C |
|
|
Over 32°C |
|||
|
|
|
|
|
|
|
|
|
||||
Deicing Time |
12mins |
|
11mins |
|
|
10mins |
|
Heating Operation |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Priority II |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T1T2=Td |
Over 3.5°C |
|
3.0 3.5°C |
|
2.5 3.0°C |
|
2.0 2.5°C |
|
below 2.0°C |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Deicing Time |
12mins |
|
11mins |
|
10mins |
|
9mins |
|
Heating Operation |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
- 18 -
9. Soft Dry Operation.
•During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compressor OFF temperature is the setting temperature minus 0.5°C.
•When the room temperature rises over the compressor ON temperature, the operation mode is switched to the cooling mode.
•When the room temperature falls between the compressor ON temperature and OFF temperature, the operation mode is switched to the Soft Dry Operation.
In this temperature range, 10min. Dry operation, 5.5min operation OFF, 1.5min. only fan operation repeat. During 10min Dry operation, even if the room temperature falls below compressor OFF temperature, 10min(MAX) Compressor ON from starting of Dry operation which includes 4 min. Compressor ON operation below the compressor OFF temperature.
•In micom dehumidify mode, control of fan speed is as following.
|
|
|
|
|
|
|
Operation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cooling |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
ROOM TEMP. |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
Dry operation |
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
SETTING TEMP.+1°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
(COMP. ON) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
maximum |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 minutes |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
SETTING TEMP.-0.5°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
(COMP. OFF) |
|
|
|
|
|
1 minutes |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
1.5 minutes |
|
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 minutes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
maximum |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
2 minutes |
|
|
|
|
|
|
|
|
5.5 minutes |
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
10 minutes |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INDOOR FAN SPEED |
Selecting |
OFF |
LOW |
LOW |
OFF |
LOW |
LOW |
fan speed |
|||||||
COMPRESSOR |
ON |
OFF |
|
ON |
OFF |
|
ON |
10. Forced operation
•If you lose wireless remote controller, you can operate the unit with forced operation switch.
•The standard conditions are as following.
|
Cooling Model |
|
Heat pump Model |
|
|
|
|
|
|
|
Room Temp ≥ 24°C |
21°C ≤Room Temp 24°C |
Room Temp 21°C |
|
|
|
|||
|
|
|
|
|
Operation Mode |
Cooling |
Cooling |
Soft Dry |
Heating |
|
|
|
|
|
Indoor Fan Speed |
High |
High |
Low |
High |
|
|
|
|
|
Setting Temp. |
22°C |
22°C |
Room Temp. |
24°C |
|
|
|
|
|
- 19 -
Display Function
1. Heating Model |
2.Cooling Model |
|
|
Operation Indicator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation Indicator |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Cooling, Soft Dry, Fan, Heating |
|
|
|
|
|
|
|
|
||||||
|
• Cooling, Soft Dry, Fan, Heating |
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Timer Indicator |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
Timer Indicator |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Timer Mode |
• Timer Mode |
|
Sleep Timer Indicator |
Sleep Timer Indicator |
|
• Sleep Mode |
• Sleep Mode |
|
Deicer Indicator |
Outdoor unit operation |
OUT |
|
|
DOOR |
• Hot-start, Deice |
• Outdoor Unit Operating or not |
|
Self-diagnosis Function
1. Protection of the eveporator pipe from frosting
If the temperature of the indoor pipe is below 0°C after 7 mins from starting the compressor, the compressor and the outdoor fan is stopped, and then after 3 mins delay of the compressor and the temperature of the indoor pipe is over 7°C, the compressor and the outdoor fan is reoperated.
2. Thermistor Cut Off of Short
Cut Off/Short : Blinks on and off the operation mode LED. (0.5 sec ON/3 sec OFF)
- 20 -
Installation
1. Installation of Indoor, Outdoor unit
1) Selection of the best location
1. Indoor unit.
•There should not be any heat source or steam near the unit.
•There should not be any obstacles to prevent the air circulation.
•A place where air circulation in the room will be good.
•A place where drainage can be easily obtained.
•A place where noise prevention is taken into consideration.
•Do not install the unit near the door way.
•Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles.
More than |
More than 5 cm |
5 cm |
|
More than eye-level |
More than |
5 cm |
2. Outdoor unit.
•If an awning is built over the unit to prevent direct sunlight or rain exposure, be careful that heat radia-
tion from the condenser is not restricted. |
More than 10 cm |
More than 10 cm |
|
||
• There should not be any animals or plants which |
|
|
could be affected by hot air discharged. |
|
|
• Ensure the spaces indicated by arrows from the wall, |
|
|
ceiling, fence, or other obstacles. |
|
|
|
More than 70 cm |
|
- 21 -
2) Indoor Unit Installation
The mounting wall should be strong and solid enough to prevent it from the vibration.
1.Mount the installation plate on the wall with four Type "A" screws.
•Always mount the Installation plate horizontally by aligning the marking-off line with using the thread and a level.
2.Drill the piping hole with 70mm dia. holecore drill.
•Drill the piping hole at either the right or the left and the hole should be slightly slant to the outdoor side.
Installation Plate
Type "A" screw |
marking-off line |
Thread
Weight
The lower left and right side of Installation Plate
<7K, 9K BTU>
Left rear piping |
Right rear piping |
80mm |
|
20mm |
20mm |
|
50mm |
ø 70mm |
ø 70mm |
<11K, 12K, 14K BTU> |
|
Left rear piping |
Right rear piping |
A |
A |
Center |
Center |
A |
A |
ø 70mm |
ø 70mm |
WALL |
|
Indoor |
Outdoor |
|
5~7mm |
- 22 -