KROHNE H250-RR User Manual

Variable area flowmeter (rotameter)
Application Information Sheet
Company name:
Address:
End user (destination):
General Information
Equipment tag #
Piping information,
Meter orientation,
Meter scale range,
Horizontal
Process conditions
Medium name,
Medium properties,
Medium temperature,
System pressure,
Fow rate,
Equipment specifications
Agency approvals,
FM IS (C1, D1)
Accuracy class,
Measuring range,
Cone material,
Float material,
Process connections,
ASME 150#
Pointer damping,
Limit switch (s),
Integrated valve,
dP pressure regulator,
Output signal,
Communications,
Pipe size:
Vertical
Density
Normal
Normal
Normal
Without
1.0%
10:1
SST
SST
Size:
Without
Without
Without
Without
No, local display only
HART
Profibus PA
inltet location
bottom valve
1-limit switch
yes
ASME 300#
Aluminum
glass
100:1
SIL1 certififed
FM XP (C1, D1)
1.6%
Flow direction from left to right
Flow direction from bottom to top (standard)
Contact name:
Phone number:
Email address:
inch NPT
Foundation Fieldbus
current output
outlet location
top valve
2-limit swtiches
ASME 600#
PTFE
PTFE lined
2.5%
FM NI (C1, D2)
SIL2 certified
pulse output
describe:
ASME 900#
Titanium
Titanium
4.0%
FDA approved
6.0%
Triament
Ceramic
ASME 1500#
TFM/ ceramic
Polypropylene
(recommended for gas applications)
Material:
Flow direction from top to bottom
Flow direction from right to left
to
Sp. gravity
Minimum
Minimum
Minimum
liquid state
Viscosity
Maximum
Maximum
Maximum
gas state
°F
psia
units:°Cpsig
bara
barg
page 1 of 2
Raised face
H250 Series H250 H/U/C/HT Special Series DK32 Series DK37 Series
Accuracy class 1.6% Accuracy class 2.5%
Accuracy class 4.0%
Accuracy class 2.5%
SIL 2 compliant
Spring-loaded for horizontal or
• liquids or gas service
• liquid or gas service
• Totalizer
vertical flow down installation
• Integrated valve option
• Integrated valve option
• 2-wire analog output 4-20mA HART
• dP regulator valve option
• dP regulator option
• Foundation Fieldbus or Profibus PA
• 2 optional limit switches
• Food & Pharma compliant
• PTFE or ceramic lined options
or mA analog output
• SST indicator housing option
• High temperatures to 752°F
• High pressures to 43,000 psi
VA40 Series VA45 Series GA24 Series
DK46,47,48 & 800 Series
• Accuracy class 1.0%
• Accuracy class 2.5%
• Accuracy class 1.0%
• Accuracy 1% to 4%
• Glass cone protected by metal
• Glass cone protected by metal • Liquid or gas service
• Integrated valve option
• Liquid or gas service • Gas service at low pressures • 2 optional limit switches
• dP regulator option
• Food & Pharma compliant • Food & Pharma compliant
• PTFE lined option
• 2 optional limit switches
Metal measuring cone
Glass measuring cone
• Increased measuring range 100:1
KROHNE Variable area (rotameters)
Notes/ comments:
Positive material identification (PMI)
Material test certification
Construction drawing (GA) for approval
Certified drawing (GA)
Certificate of compliance
KROHNE standard (IOM + calibration certificate)
Radiographic examination (RT)
Dye penetration test (PT)
Inspection certificate 3.1
Leakage test + certificate
Pressure test
Hardness test
NACE MR0175
Confirmation of accuracy
5-point calibration certificate
10-point calibration certificate
Equipment tag #
Documentation
Variable area flowmeter (rotameter)
Application Information Sheet
(QA/QC)
page 2 of 2
Loading...