All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without
the prior written authorisation of KROHNE Messtechnik GmbH.
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
DK46 - DK800
1.1 Intended use
The variable area flowmeters are suitable for measuring gases, vapors and liquids.
These flowmeters are particularly suitable for measuring:
• Liquids
• Hydrocarbons
• Water
• Chemicals with low corrosiveness
• Industrial gases
DANGER!
In case of instruments which are used in explosive endangered areas please consider the
supplementary installation and operating instructions mentioned in the Ex-manual.
WARNING!
The operator shall bear sole responsibility for the use of the flowmeters with regard to
suitability, intended use and corrosion resistance of the materials used to the process product.
The manufacturer shall not be liable for any damage resulting from improper use or use for
other than the intended purpose.
Do not use any abrasive or highly viscous process products.
SAFETY INSTRUCTIONS 1
1.2 Certifications
CE marking
The flowmeter meets the statutory requirements of the following EC directives:
• EMC Directive 2004/108/EC for instruments with electrical options
• ATEX Directive 94/9/EC for instruments in Ex-areas
The manufacturer certifies successful testing of the product by providing the CE Declaration of
Conformity.
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
5
1 SAFETY INSTRUCTIONS
1.3 Safety instructions from the manufacturer
1.3.1 Copyright and data protection
The contents of this document have been created with great care. Nevertheless, we provide no
guarantee that the contents are correct, complete or up-to-date.
The contents and works in this document are subject to copyright. Contributions from third
parties are identified as such. Reproduction, processing, dissemination and any type of use
beyond what is permitted under copyright requires written authorisation from the respective
author and/or the manufacturer.
The manufacturer tries always to observe the copyrights of others, and to draw on works created
in-house or works in the public domain.
The collection of personal data (such as names, street addresses or e-mail addresses) in the
manufacturer's documents is always on a voluntary basis whenever possible. Whenever
feasible, it is always possible to make use of the offerings and services without providing any
personal data.
DK46 - DK800
We draw your attention to the fact that data transmission over the Internet (e.g. when
communicating by e-mail) may involve gaps in security. It is not possible to protect such data
completely against access by third parties.
We hereby expressly prohibit the use of the contact data published as part of our duty to publish
an imprint for the purpose of sending us any advertising or informational materials that we have
not expressly requested.
1.3.2 Disclaimer
The manufacturer will not be liable for any damage of any kind by using its product, including,
but not limited to direct, indirect or incidental and consequential damages.
This disclaimer does not apply in case the manufacturer has acted on purpose or with gross
negligence. In the event any applicable law does not allow such limitations on implied warranties
or the exclusion of limitation of certain damages, you may, if such law applies to you, not be
subject to some or all of the above disclaimer, exclusions or limitations.
Any product purchased from the manufacturer is warranted in accordance with the relevant
product documentation and our Terms and Conditions of Sale.
The manufacturer reserves the right to alter the content of its documents, including this
disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable
in any way for possible consequences of such changes.
6
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
DK46 - DK800
1.3.3 Product liability and warranty
The operator shall bear responsibility for the suitability of the device for the specific purpose.
The manufacturer accepts no liability for the consequences of misuse by the operator. Improper
installation and operation of the devices (systems) will cause the warranty to be void. The
respective "Standard Terms and Conditions" which form the basis for the sales contract shall
also apply.
1.3.4 Information concerning the documentation
To prevent any injury to the user or damage to the device it is essential that you read the
information in this document and observe applicable national standards, safety requirements
and accident prevention regulations.
If this document is not in your native language and if you have any problems understanding the
text, we advise you to contact your local office for assistance. The manufacturer can not accept
responsibility for any damage or injury caused by misunderstanding of the information in this
document.
This document is provided to help you establish operating conditions, which will permit safe and
efficient use of this device. Special considerations and precautions are also described in the
document, which appear in the form of underneath icons.
SAFETY INSTRUCTIONS 1
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
7
1 SAFETY INSTRUCTIONS
1.3.5 Warnings and symbols used
Safety warnings are indicated by the following symbols.
DANGER!
This information refers to the immediate danger when working with electricity.
DANGER!
This warning refers to the immediate danger of burns caused by heat or hot surfaces.
DANGER!
This warning refers to the immediate danger when using this device in a hazardous atmosphere.
DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.
DK46 - DK800
WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.
CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.
INFORMATION!
These instructions contain important information for the handling of the device.
LEGAL NOTICE!
This note contains information on statutory directives and standards.
• HANDLING
HANDLING
HANDLINGHANDLING
This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
iRESULT
RESULT
RESULTRESULT
This symbol refers to all important consequences of the previous actions.
1.4 Safety instructions for the operator
WARNING!
In general, devices from the manufacturer may only be installed, commissioned, operated and
maintained by properly trained and authorized personnel.
This document is provided to help you establish operating conditions, which will permit safe and
efficient use of this device.
8
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
DK46 - DK800
2.1 Scope of supply
INFORMATION!
Inspect the cartons carefully for damage or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.
INFORMATION!
Check the packing list to check if you received completely all that you ordered.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
DEVICE DESCRIPTION 2
Figure 2-1: Scope of delivery
1 Flowmeter in the ordered version
2 Manual
3 Certificates, calibration certificate (supplied to order only)
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
9
2 DEVICE DESCRIPTION
2.2 Device versions
DK46 - DK800
Figure 2-2: Device versions
1 DK46 with valve and an overall length of 111 mm
2 DK47 with valve and an overall length of 196 mm
3 DK48 with valve and an overall length of 346 mm
4 DK800 with valve and an overall length of 146 mm
Figure 2-3: DK47 with differential pressure regulators
1 DK47 with inlet pressure regulator
2 DK47 with outlet pressure regulator
10
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
DK46 - DK800
2.3 Nameplate
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
DEVICE DESCRIPTION 2
Figure 2-4: Nameplates (Examples)
1 Type of meter
2 Manufacturer
3 Appointed ATEX body
4 Design data: temperature & pressure rating
5 DGRL data
6 Ex data
7 Electrical connection data
8 KROHNE website
Additional markings on the measuring device
• SN - serial number
• SO - sales order / item
• Tag-No - Measuring point identifier
• MD - manufacturing date
• PA - KROHNE order
• Vx - product configurator code
• AC - article code
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
11
2 DEVICE DESCRIPTION
2.4 Description code
The description code* consists of the following elements:
1 R - with integrated inlet pressure regulator (DKR46 only)
2 Device type:
46 - Overall length of measuring cone 65 mm
47 - Overall length of measuring cone 150 mm
48 - Overall length of measuring cone 300 mm
800 - Overall length of measuring cone 100 mm
3 Material for top and bottom fittings
N - brass
R - stainless steel
PV - PVDF
DK46 - DK800
4 Differential pressure regulators
RE - inlet pressure regulator
RA - outlet pressure regulator
5 K1 - one limit switch / K2 - two limit switches
* positions which are not needed are omitted (no blank positions)
12
www.krohne.com05/2011 - 4000302403 MA DK46-800-R03-en
Loading...
+ 28 hidden pages