2 Installation
This product
Expansion
connector
Amplifier
Load
Load
10 to 30 VDC
0 V
Brown
(Separate control
output*)
Red
(common output)
Pink
(common input)
Blue
Multi-output Unit
FS-MC8N/P
Instruction Manual
Read this manual before using the product in
order to achieve maximum performance.
Keep this manual in a safe place after reading it
so that it can be used at any time.
Symbols
The following symbols are used in this instruction manual to enable the recognition
of important information at a glance. Be sure to read these messages carefully.
It indicates a hazardous situation which, if not avoided, will result
DANGER
in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
WARNING
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
CAUTION
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product
NOTICE
damage as well as property damage.
It indicates tips for better understanding or useful information.
1 Before Operation
Safety Precautions
•
This product is only intended to detect objects. Do not use this product for the
purpose of protecting a human body or a part of a human body.
DANGER
•
This product is not intended for use as an explosion-proof product. Do not use
this product in a hazardous location and/or potentially explosive atmosphere.
•
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
WARNING
•
This is a direct current (DC) power supply type sensor. Application of an
alternating current may result in explosion or fire.
•
Use separate conduits for power lines and high-voltage lines. Use of a common
conduit may result in device malfunction due to noise or damage to the sensor.
•
NOTICE
Precautions on Regulations and Standards
CE Marking
KEYENCE Corporation has confirmed, on the basis of the following specifications,
that this product complies with the essential requirements of the applicable EU
Directive(s). Be sure to consider the following specifications when using this
product in the member states of the European Union.
z EMC Directive, applicable standard: EN61326-1, Class A
Ensure that the cable length is 30 meters or less.
These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of the EMC
Directive. The manufacturer of the end-product is solely responsible for confirming
the compliance of the end-product itself according to the EMC Directive.
UL Certificate
This product is a UL/c-UL Listed product.
• UL File No. E222809 • Category QUYX/QUYX7
Be sure to consider the following specifications when using this product as a UL/
c-UL Listed product.
• Use this product with one of the following power supplies.
• UL/CSA certified power supply that provides Class 2 output as defined in the
• UL/CSA certified power supply that has been evaluated as a Limited Energy
• Ensure the circuits to be connected to the input/output terminals are SELV
Circuits.
• Use this product under pollution degree 2.
• Use this product at the altitude of 2000 m or less.
• Indoor use only.
FCC Regulations
This product complies with the following regulations specified by the FCC.
• Applicable regulation FCC Part 15 Subpart B Class A
• This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interface, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
• FCC Caution
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Always ground the frame ground terminal when using an off-the-shelf switching
regulator.
•
Do not use this product outdoors.
NFPA70 (NEC: National Electrical Code) and CEC (Canadian Electrical Code).
circuit as defined in UL61010-1 and CAN/CSA-C22.2 No. 61010-1.
Expansion Unit Connection
This section explains how to install this product on a DIN rail and how to connect
this product to an expansion unit.
Up to 8 expansion units can be connected to 1 instance of this product. However,
each dual output type will be treated as 2 expansion units.
Turn off the power supply before connecting this product to an
expansion unit.
1 Align the claw at the bottom of this product with the DIN rail. While pushing this
product in the direction of arrow 1, push down in the direction of arrow 2.
Reference
To remove this product, raise it in the direction of arrow 3 while pushing
2 Repeat step 1 to install expansion units on the DIN rail and connect them to this
3 Mount the end units (OP-26751: a two-unit set is included with this product) on
it in the direction of arrow 1.
product.
If the amplifier connector has an expansion protection cover, remove the cover
before connecting the sensor.
Securely connect this product and the expansion units. If they are
connected at an angle or are not inserted fully, this product and the
expansion units may be damaged when the power is turned on.
both sides of this product and the expansion units. Then, fix the end units in
place with the screws on the top of each end unit.
(Tightening torque: 0.6 N•m or less)
Mount the end units on the DIN rail in the same manner as described above.
3 Connection Diagram
FS-MC8N FS-MC8P
Brown
(Separate control
output*)
Red
(common output)
Pink
(common input)
Blue
* Black, white, orange, yellow, green, violet, gray, pink/violet
10 to 30 VDC
Load
Load
0 V
Package Contents
• Main unit • Instruction manual • End units
1
E FS-MC8N/P IM

4 Wire Colors
Usage example:
When units are connected as shown in the following figure, the
corresponding wire colors are assigned as shown in the table below.
The LV-N12 is a dual output type, so it is treated as 2 expansion units.
FS-N40
LV- N1 2
AP-N10
NU-EN8N
Control output Wire color
FS-N40 output Black
LV-N12 output 1 White
LV-N12 output 2 Orange
AP-N10 output Yellow
NU-EN8N No. 1 output Green
NU-EN8N No. 2 output Violet
NU-EN8N No. 3 output Gray
NU-EN8N No. 4 output
Pink/violet
In the above usage example, the No. 5 to No. 8 outputs of the NU-EN8N
cannot be used.
* The MU-N11/N12 and OP-87199 cannot be used with this product.
FS-MC8N/P
SAVE button
Save the settings of the
connected expansion
units.
SELECT button
Select the memory
number.
LOAD button
Write settings to the
connected expansion
units.
LOCK indicator/button
This is both an indicator
and a button.
It lights (in orange) when
the operation of the buttons
are disabled.
MEMORY indicators
The indicator whose
memory number matches
the expansion units model
configuration and settings
will be lit (in orange). While
a memory number is
selected, the
corresponding memory
indicator blinks.
STATUS indicator
Display
status
Product status
Green (lit) Normal operating status
Off Power OFF
Green
(blinking)
SAVE, LOAD,
or initialization being
performed
Red
(blinking)
Error status
Saving settings [SAVE]
Up to three sets of settings for the expansion units connected to this product
can be saved.
1 Press the SELECT button to select the memory number in which to save the
settings.
(Each time the SELECT button is pressed, the memory number that is blinking changes.)
2 With the desired MEMORY indicator blinking, hold down the SAVE button
for 3 seconds or more.
Writing settings [LOAD]
Write the saved settings on this product to the connected expansion units.
1 Press the SELECT button to select the memory number in which the set-
tings to write have been inserted.
(Each time the SELECT button is pressed, the memory number that is blinking changes.)
2 With the desired MEMORY indicator blinking, hold down the LOAD button
for 3 seconds or more.
* An error will occur if the settings to write do not match the number of
expansion units, the expansion unit models, and/or the position in which
the expansion units are connected. (See page 3.)
Preventing incorrect operations (batch key lock) [LOCK]
Disable button operations not only on this product but also on all expansion
units that are connected to this product.
1 Hold down the LOCK button for 3 seconds or more. Cancel: Use the same
procedure.
Common input
A common external input signal can be sent to the expansion units that
support external input by controlling the common input (pink wire) of this
product.
* For details on the expansion units that support the common input, see
page 3.
* If the external input for an expansion unit is in already in the ON state, the
common external input will be ignored by that unit.
Common output
When an error occurs on this product or on an expansion unit connected to
this product, the common output (red wire) turns ON. If the "Limit Detection" or
“Limit Setting Output Mode” of an expansion unit is being used, the alarm
output of each function will be linked to the common output (red wire).
Setting initialization
Initialize all the settings and return this product to its factory default state.
1 Hold down the SAVE button, LOAD button, and LOCK button for 3 seconds
or more.
The connected expansion units are not initialized.
Save lock function
This function prevents incorrect operations of the SAVE button and only the
SAVE button.
By using the LOCK button at the same time that the settings are saved, it can
be ensured that it is not easy to overwrite the settings.
1 Press the SELECT button to select the memory number in which to save the
settings.
(Each time the SELECT button is pressed, the memory number that is
blinking changes.)
2 With the desired MEMORY indicator blinking, hold down the LOCK button
and the SAVE button for 3 seconds or more.
To overwrite the settings, perform the save lock function operation again.
(The settings cannot be saved by just pressing the SAVE button.)
To cancel the save lock function, initialize the settings.
(By initializing the settings, this product will return to its factory default state.)
By connecting expansion units to this product, it is possible to send independent
control output information from each expansion unit through this device.
The control outputs are assigned to the wire colors in the following table in the
order in which the expansion units are connected next to this product.
1st unit
Red
Pink
Blue
Black
Brown
White
Orange
Brown Blue Pink Red
Power
supply
0 V
Common
input
Yellow
Gray
Violet
Green
Common
output
Pink/violet
FS-MC8N/P
FS-N40 x 8
6 Basic Operation and Functions
Black White Orange Yellow Green
Unit 1
output
Unit 2
output
Unit 3
output
Unit 4
output
Unit 5
output
Violet Gray
Unit 6
output
Unit 7
output
Pink/
violet
Unit 8
output
In the above example, only single output types have been used. When dual output
types are used, each dual output type is treated as 2 expansion units.
7 Useful Functions
If the order in which expansion units are connected is changed, the
wire colors corresponding to the outputs will also change.
5 Part Names and Functions
E FS-MC8N/P IM
2