Keyence FS-MC8P, FS-MC8N Instruction Manual

Reference
96M14747

2 Installation

NOTICE
NOTICE
(1)
(2)
(3)
This product
Expansion connector
Amplifier
End unit
End unit
Load
Load
10 to 30 VDC
0 V
Brown
(Separate control output*)
Red (common output)
Pink (common input)
Blue
Multi-output Unit
FS-MC8N/P
Instruction Manual
Read this manual before using the product in order to achieve maximum performance. Keep this manual in a safe place after reading it so that it can be used at any time.
Symbols
The following symbols are used in this instruction manual to enable the recognition of important information at a glance. Be sure to read these messages carefully.
It indicates a hazardous situation which, if not avoided, will result
DANGER
in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
WARNING
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
CAUTION
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product
NOTICE
damage as well as property damage.
It indicates tips for better understanding or useful information.

1 Before Operation

Safety Precautions

This product is only intended to detect objects. Do not use this product for the purpose of protecting a human body or a part of a human body.
DANGER
This product is not intended for use as an explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
WARNING
This is a direct current (DC) power supply type sensor. Application of an alternating current may result in explosion or fire.
Use separate conduits for power lines and high-voltage lines. Use of a common conduit may result in device malfunction due to noise or damage to the sensor.
NOTICE

Precautions on Regulations and Standards

CE Marking
KEYENCE Corporation has confirmed, on the basis of the following specifications, that this product complies with the essential requirements of the applicable EU Directive(s). Be sure to consider the following specifications when using this product in the member states of the European Union.
z EMC Directive, applicable standard: EN61326-1, Class A
Ensure that the cable length is 30 meters or less. These specifications do not give any guarantee that the end-product with this product incorporated complies with the essential requirements of the EMC Directive. The manufacturer of the end-product is solely responsible for confirming the compliance of the end-product itself according to the EMC Directive.
UL Certificate
This product is a UL/c-UL Listed product.
UL File No. E222809 Category QUYX/QUYX7 Be sure to consider the following specifications when using this product as a UL/ c-UL Listed product.
Use this product with one of the following power supplies.
UL/CSA certified power supply that provides Class 2 output as defined in the
UL/CSA certified power supply that has been evaluated as a Limited Energy
Ensure the circuits to be connected to the input/output terminals are SELV
Circuits.
Use this product under pollution degree 2.
Use this product at the altitude of 2000 m or less.
Indoor use only.
FCC Regulations
This product complies with the following regulations specified by the FCC.
Applicable regulation FCC Part 15 Subpart B Class A
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Always ground the frame ground terminal when using an off-the-shelf switching regulator.
Do not use this product outdoors.
NFPA70 (NEC: National Electrical Code) and CEC (Canadian Electrical Code).
circuit as defined in UL61010-1 and CAN/CSA-C22.2 No. 61010-1.

Expansion Unit Connection

This section explains how to install this product on a DIN rail and how to connect this product to an expansion unit. Up to 8 expansion units can be connected to 1 instance of this product. However, each dual output type will be treated as 2 expansion units.
Turn off the power supply before connecting this product to an expansion unit.
1 Align the claw at the bottom of this product with the DIN rail. While pushing this
product in the direction of arrow 1, push down in the direction of arrow 2.
Reference
To remove this product, raise it in the direction of arrow 3 while pushing
2 Repeat step 1 to install expansion units on the DIN rail and connect them to this
3 Mount the end units (OP-26751: a two-unit set is included with this product) on
it in the direction of arrow 1.
product.
If the amplifier connector has an expansion protection cover, remove the cover before connecting the sensor.
Securely connect this product and the expansion units. If they are connected at an angle or are not inserted fully, this product and the expansion units may be damaged when the power is turned on.
both sides of this product and the expansion units. Then, fix the end units in place with the screws on the top of each end unit. (Tightening torque: 0.6 N•m or less)
Mount the end units on the DIN rail in the same manner as described above.

3 Connection Diagram

FS-MC8N FS-MC8P
Brown
(Separate control output*)
Red (common output)
Pink (common input)
Blue
* Black, white, orange, yellow, green, violet, gray, pink/violet
10 to 30 VDC
Load
Load
0 V

Package Contents

Main unit Instruction manual End units
1
E FS-MC8N/P IM

4 Wire Colors

Reference
Usage example: When units are connected as shown in the following figure, the corresponding wire colors are assigned as shown in the table below. The LV-N12 is a dual output type, so it is treated as 2 expansion units.
FS-N40
LV- N1 2
AP-N10
NU-EN8N
Control output Wire color
FS-N40 output Black
LV-N12 output 1 White
LV-N12 output 2 Orange
AP-N10 output Yellow
NU-EN8N No. 1 output Green
NU-EN8N No. 2 output Violet
NU-EN8N No. 3 output Gray
NU-EN8N No. 4 output
Pink/violet
In the above usage example, the No. 5 to No. 8 outputs of the NU-EN8N cannot be used.
* The MU-N11/N12 and OP-87199 cannot be used with this product.
FS-MC8N/P
SAVE button
Save the settings of the connected expansion units.
SELECT button
Select the memory number.
LOAD button
Write settings to the connected expansion units.
LOCK indicator/button
This is both an indicator and a button. It lights (in orange) when the operation of the buttons are disabled.
MEMORY indicators
The indicator whose memory number matches the expansion units model configuration and settings will be lit (in orange). While a memory number is selected, the corresponding memory indicator blinks.
STATUS indicator
Display
status
Product status
Green (lit) Normal operating status
Off Power OFF
Green (blinking)
SAVE, LOAD, or initialization being performed
Red (blinking)
Error status
Saving settings [SAVE]
Up to three sets of settings for the expansion units connected to this product can be saved.
1 Press the SELECT button to select the memory number in which to save the
settings. (Each time the SELECT button is pressed, the memory number that is blink­ing changes.)
2 With the desired MEMORY indicator blinking, hold down the SAVE button
for 3 seconds or more.
Writing settings [LOAD]
Write the saved settings on this product to the connected expansion units.
1 Press the SELECT button to select the memory number in which the set-
tings to write have been inserted. (Each time the SELECT button is pressed, the memory number that is blink­ing changes.)
2 With the desired MEMORY indicator blinking, hold down the LOAD button
for 3 seconds or more.
* An error will occur if the settings to write do not match the number of
expansion units, the expansion unit models, and/or the position in which the expansion units are connected. (See page 3.)
Preventing incorrect operations (batch key lock) [LOCK]
Disable button operations not only on this product but also on all expansion units that are connected to this product.
1 Hold down the LOCK button for 3 seconds or more. Cancel: Use the same
procedure.
Common input
A common external input signal can be sent to the expansion units that support external input by controlling the common input (pink wire) of this product. * For details on the expansion units that support the common input, see
page 3.
* If the external input for an expansion unit is in already in the ON state, the
common external input will be ignored by that unit.
Common output
When an error occurs on this product or on an expansion unit connected to this product, the common output (red wire) turns ON. If the "Limit Detection" or “Limit Setting Output Mode” of an expansion unit is being used, the alarm output of each function will be linked to the common output (red wire).
Setting initialization
Initialize all the settings and return this product to its factory default state.
1 Hold down the SAVE button, LOAD button, and LOCK button for 3 seconds
or more.
The connected expansion units are not initialized.
Save lock function
This function prevents incorrect operations of the SAVE button and only the SAVE button. By using the LOCK button at the same time that the settings are saved, it can be ensured that it is not easy to overwrite the settings.
1 Press the SELECT button to select the memory number in which to save the
settings. (Each time the SELECT button is pressed, the memory number that is blinking changes.)
2 With the desired MEMORY indicator blinking, hold down the LOCK button
and the SAVE button for 3 seconds or more.
To overwrite the settings, perform the save lock function operation again. (The settings cannot be saved by just pressing the SAVE button.)
To cancel the save lock function, initialize the settings. (By initializing the settings, this product will return to its factory default state.)
By connecting expansion units to this product, it is possible to send independent control output information from each expansion unit through this device. The control outputs are assigned to the wire colors in the following table in the order in which the expansion units are connected next to this product.
1st unit
Red
Pink
Blue
Black
Brown
White
Orange
Brown Blue Pink Red
Power supply
0 V
Common
input
Yellow
Gray
Violet
Green
Common
output
Pink/violet
FS-MC8N/P
FS-N40 x 8

6 Basic Operation and Functions

Black White Orange Yellow Green
Unit 1
output
Unit 2
output
Unit 3
output
Unit 4
output
Unit 5
output
Violet Gray
Unit 6
output
Unit 7
output
Pink/ violet
Unit 8
output
In the above example, only single output types have been used. When dual output types are used, each dual output type is treated as 2 expansion units.

7 Useful Functions

If the order in which expansion units are connected is changed, the wire colors corresponding to the outputs will also change.

5 Part Names and Functions

E FS-MC8N/P IM
2