Keyence FS-MC8P, FS-MC8N Instruction Manual

Page 1
Reference
96M14747

2 Installation

NOTICE
NOTICE
(1)
(2)
(3)
This product
Expansion connector
Amplifier
End unit
End unit
Load
Load
10 to 30 VDC
0 V
Brown
(Separate control output*)
Red (common output)
Pink (common input)
Blue
Multi-output Unit
FS-MC8N/P
Instruction Manual
Read this manual before using the product in order to achieve maximum performance. Keep this manual in a safe place after reading it so that it can be used at any time.
Symbols
The following symbols are used in this instruction manual to enable the recognition of important information at a glance. Be sure to read these messages carefully.
It indicates a hazardous situation which, if not avoided, will result
DANGER
in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
WARNING
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
CAUTION
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product
NOTICE
damage as well as property damage.
It indicates tips for better understanding or useful information.

1 Before Operation

Safety Precautions

This product is only intended to detect objects. Do not use this product for the purpose of protecting a human body or a part of a human body.
DANGER
This product is not intended for use as an explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
WARNING
This is a direct current (DC) power supply type sensor. Application of an alternating current may result in explosion or fire.
Use separate conduits for power lines and high-voltage lines. Use of a common conduit may result in device malfunction due to noise or damage to the sensor.
NOTICE

Precautions on Regulations and Standards

CE Marking
KEYENCE Corporation has confirmed, on the basis of the following specifications, that this product complies with the essential requirements of the applicable EU Directive(s). Be sure to consider the following specifications when using this product in the member states of the European Union.
z EMC Directive, applicable standard: EN61326-1, Class A
Ensure that the cable length is 30 meters or less. These specifications do not give any guarantee that the end-product with this product incorporated complies with the essential requirements of the EMC Directive. The manufacturer of the end-product is solely responsible for confirming the compliance of the end-product itself according to the EMC Directive.
UL Certificate
This product is a UL/c-UL Listed product.
UL File No. E222809 Category QUYX/QUYX7 Be sure to consider the following specifications when using this product as a UL/ c-UL Listed product.
Use this product with one of the following power supplies.
UL/CSA certified power supply that provides Class 2 output as defined in the
UL/CSA certified power supply that has been evaluated as a Limited Energy
Ensure the circuits to be connected to the input/output terminals are SELV
Circuits.
Use this product under pollution degree 2.
Use this product at the altitude of 2000 m or less.
Indoor use only.
FCC Regulations
This product complies with the following regulations specified by the FCC.
Applicable regulation FCC Part 15 Subpart B Class A
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Always ground the frame ground terminal when using an off-the-shelf switching regulator.
Do not use this product outdoors.
NFPA70 (NEC: National Electrical Code) and CEC (Canadian Electrical Code).
circuit as defined in UL61010-1 and CAN/CSA-C22.2 No. 61010-1.

Expansion Unit Connection

This section explains how to install this product on a DIN rail and how to connect this product to an expansion unit. Up to 8 expansion units can be connected to 1 instance of this product. However, each dual output type will be treated as 2 expansion units.
Turn off the power supply before connecting this product to an expansion unit.
1 Align the claw at the bottom of this product with the DIN rail. While pushing this
product in the direction of arrow 1, push down in the direction of arrow 2.
Reference
To remove this product, raise it in the direction of arrow 3 while pushing
2 Repeat step 1 to install expansion units on the DIN rail and connect them to this
3 Mount the end units (OP-26751: a two-unit set is included with this product) on
it in the direction of arrow 1.
product.
If the amplifier connector has an expansion protection cover, remove the cover before connecting the sensor.
Securely connect this product and the expansion units. If they are connected at an angle or are not inserted fully, this product and the expansion units may be damaged when the power is turned on.
both sides of this product and the expansion units. Then, fix the end units in place with the screws on the top of each end unit. (Tightening torque: 0.6 N•m or less)
Mount the end units on the DIN rail in the same manner as described above.

3 Connection Diagram

FS-MC8N FS-MC8P
Brown
(Separate control output*)
Red (common output)
Pink (common input)
Blue
* Black, white, orange, yellow, green, violet, gray, pink/violet
10 to 30 VDC
Load
Load
0 V

Package Contents

Main unit Instruction manual End units
1
E FS-MC8N/P IM
Page 2

4 Wire Colors

Reference
Usage example: When units are connected as shown in the following figure, the corresponding wire colors are assigned as shown in the table below. The LV-N12 is a dual output type, so it is treated as 2 expansion units.
FS-N40
LV- N1 2
AP-N10
NU-EN8N
Control output Wire color
FS-N40 output Black
LV-N12 output 1 White
LV-N12 output 2 Orange
AP-N10 output Yellow
NU-EN8N No. 1 output Green
NU-EN8N No. 2 output Violet
NU-EN8N No. 3 output Gray
NU-EN8N No. 4 output
Pink/violet
In the above usage example, the No. 5 to No. 8 outputs of the NU-EN8N cannot be used.
* The MU-N11/N12 and OP-87199 cannot be used with this product.
FS-MC8N/P
SAVE button
Save the settings of the connected expansion units.
SELECT button
Select the memory number.
LOAD button
Write settings to the connected expansion units.
LOCK indicator/button
This is both an indicator and a button. It lights (in orange) when the operation of the buttons are disabled.
MEMORY indicators
The indicator whose memory number matches the expansion units model configuration and settings will be lit (in orange). While a memory number is selected, the corresponding memory indicator blinks.
STATUS indicator
Display
status
Product status
Green (lit) Normal operating status
Off Power OFF
Green (blinking)
SAVE, LOAD, or initialization being performed
Red (blinking)
Error status
Saving settings [SAVE]
Up to three sets of settings for the expansion units connected to this product can be saved.
1 Press the SELECT button to select the memory number in which to save the
settings. (Each time the SELECT button is pressed, the memory number that is blink­ing changes.)
2 With the desired MEMORY indicator blinking, hold down the SAVE button
for 3 seconds or more.
Writing settings [LOAD]
Write the saved settings on this product to the connected expansion units.
1 Press the SELECT button to select the memory number in which the set-
tings to write have been inserted. (Each time the SELECT button is pressed, the memory number that is blink­ing changes.)
2 With the desired MEMORY indicator blinking, hold down the LOAD button
for 3 seconds or more.
* An error will occur if the settings to write do not match the number of
expansion units, the expansion unit models, and/or the position in which the expansion units are connected. (See page 3.)
Preventing incorrect operations (batch key lock) [LOCK]
Disable button operations not only on this product but also on all expansion units that are connected to this product.
1 Hold down the LOCK button for 3 seconds or more. Cancel: Use the same
procedure.
Common input
A common external input signal can be sent to the expansion units that support external input by controlling the common input (pink wire) of this product. * For details on the expansion units that support the common input, see
page 3.
* If the external input for an expansion unit is in already in the ON state, the
common external input will be ignored by that unit.
Common output
When an error occurs on this product or on an expansion unit connected to this product, the common output (red wire) turns ON. If the "Limit Detection" or “Limit Setting Output Mode” of an expansion unit is being used, the alarm output of each function will be linked to the common output (red wire).
Setting initialization
Initialize all the settings and return this product to its factory default state.
1 Hold down the SAVE button, LOAD button, and LOCK button for 3 seconds
or more.
The connected expansion units are not initialized.
Save lock function
This function prevents incorrect operations of the SAVE button and only the SAVE button. By using the LOCK button at the same time that the settings are saved, it can be ensured that it is not easy to overwrite the settings.
1 Press the SELECT button to select the memory number in which to save the
settings. (Each time the SELECT button is pressed, the memory number that is blinking changes.)
2 With the desired MEMORY indicator blinking, hold down the LOCK button
and the SAVE button for 3 seconds or more.
To overwrite the settings, perform the save lock function operation again. (The settings cannot be saved by just pressing the SAVE button.)
To cancel the save lock function, initialize the settings. (By initializing the settings, this product will return to its factory default state.)
By connecting expansion units to this product, it is possible to send independent control output information from each expansion unit through this device. The control outputs are assigned to the wire colors in the following table in the order in which the expansion units are connected next to this product.
1st unit
Red
Pink
Blue
Black
Brown
White
Orange
Brown Blue Pink Red
Power supply
0 V
Common
input
Yellow
Gray
Violet
Green
Common
output
Pink/violet
FS-MC8N/P
FS-N40 x 8

6 Basic Operation and Functions

Black White Orange Yellow Green
Unit 1
output
Unit 2
output
Unit 3
output
Unit 4
output
Unit 5
output
Violet Gray
Unit 6
output
Unit 7
output
Pink/ violet
Unit 8
output
In the above example, only single output types have been used. When dual output types are used, each dual output type is treated as 2 expansion units.

7 Useful Functions

If the order in which expansion units are connected is changed, the wire colors corresponding to the outputs will also change.

5 Part Names and Functions

E FS-MC8N/P IM
2
Page 3

8 Amplifier (Expansion Unit) Support Table

A list of the amplifiers (expansion units) that can be connected to this product to expand the system, and the supported functions, are shown below.
9: supported,
Series Model Typ e
FS-N40 1 output 99 9 9*499
FS-N40 Series
FS-N10 Series
LV-N10 Series
PS-N10 Series
AP-N10 Series
Other NU-EN8N
*1 The types of expansion unit errors are shown below. The NU-EN8N does not sup port expansion unit errors. 9: supported,
Expansion unit error type Error description
Overcurrent error An overcurrent is flowing through the control output. 999
EEPROM error The attempt to write/read internal data failed. 9999
DATUM correction error A correction error occurred in DATUM mode. 999
APC correction error The reduction in LED light intensity exceeded the APC correction limit. 9
Head error The head cable is broken or not connected.
*2 When using the Limit Detection (limit setting output mode), it is necessary to configure settings on the expansion unit side. See the instruction manual of the expansion unit. *3 For details on the expansion unit settings, see the instruction manual (the sections related to external inputs) of the expansion unit. *4 The external input function can be used when connected to this product. *5 If the expansion unit's switch is set to [TERA] or [MEGA], the power mode setting may not be saved/written correctly. Change the switch to [SEL]. *6 Further expansion units cannot be connected after the NU-EN8N in order to expand the system.
FS-N42N 1 output 99 9 9*49
FS-N42P 1 output 99 9 9*49
FS-N44N 2 outputs 99 9 999
FS-N44P 2 outputs 99 9 999
FS-N10 1 output 99
FS-N12N 1 output 99
FS-N12P 1 output 99
FS-N12CN 1 output 99
FS-N12CP 1 output 99
FS-N12EN 1 output 99
FS-N14N 2 outputs 999(limit setting output mode) 999
FS-N14P 2 outputs 999(limit setting output mode) 999
FS-N14CP 2 outputs 999(limit setting output mode) 9
LV-N10 1 output 999(limit setting output mode) 9
LV-N12N 2 outputs 999(limit setting output mode) 999
LV-N12P 2 outputs 999(limit setting output mode) 999
LV-N12CN 1 output 999(limit setting output mode) 99*59
LV-N12CP 1 output 999(limit setting output mode) 99*59
PS-N10 1 output 99
PS-N12N 1 output 99
PS-N12P 1 output 99
PS-N12CN 1 output 99
PS-N12CP 1 output 99
AP-N10 1 output 99
AP-N10D 2 outputs 99
*6
8 outputs 9
Separate control
output
Expansion unit error output
Common output
*1
Limit Detection
-
-
-
-
-
-
-
-
-
-
-
-
-
*2
Common input
9
9
9
99*59
99*59
99*59
9
9
9
99*59
99*59
999
999
*4
*4
*4
*4
*4
*4
*4
*4
Saving settings,
*3
writing settings
*5
*5
99
*5
9
*5
9
99
99
*5
9
*5
9
*5
9
-----
-
: not supported
FS-N40/10 LV- N1 0 PS-N10 AP-N10 NU-EN8N
Supported series
--
--
----
-
999
-
: not supported
Batch key lock
9
9
9
9
9
9
9
-
-

9Error Status

Indicator Display Error name
Blinking slowly
(lights and turns off once per
second)
Blinking quickly
(lights and turns off once per
0.25 of a second)
Lit briefly one time
(lit for 0.25 of a second once
per 2 seconds)
STATUS indicator (red)
MEMORY indicator (orange)
LOCK indicator (orange)
Lit briefly twice
(lit for 0.25 of a second twice
per 2 seconds)
Blinks for 3 seconds
Blinks for 3 seconds
Common
output
Configuration
error
Overcurrent
error
Expansion unit
error
System error ON
Verification
error
Memory
selection error
Key lock error
Previous status
maintained
Previous status
maintained
Previous status
maintained
Description Confirmation method and countermeasures
The number of expansion units, the expansion unit
ON
models, or the position in which the expansion units are connected differs from the saved information.
An overcurrent is flowing through one of the separa te
ON
control outputs.
OFF An overcurrent is flowing through the common output.
ON An error has occurred on an expansion unit. Check the status of the connected expansion units.
Communication with an expansion unit has not been established.
The expansion unit configuration was changed during operation.
The sensor is damaged. Replace the expansion unit.
A function could not be executed correctly. Perfor m the operation again.
The save lock has been set. For details on the save lock function, see page 2.
The number of expansion units, the expansion unit models, or the position in which the expansion units are connected differs from the setting data that was written.
An unsupported expansion unit has been connected to expand the system.
The SAVE/LOAD button was pressed with no memory entry selected.
The batch key lock function is enabled. An operation that is disabled while the batch key lock function is enabled was performed.
Return the expansion units to their original status. When updating the expansion unit status, save the settings. Initialize the settings on this product.
Check the load and return it to a value within the rated range.
Check the load and return it to a value within the rated range.
Check whether the expansion units have been connected correctly to expand the system. Restart the system.
Check the position in which the expansion units are connected.
Return the expansion units to their original status. When changing the expansion unit status, save the settings again.
Remove the unsupported expansion unit.
Perform the setting saving/writing operation correctly. (For the operation method, see page 2.)
Release the batch key lock, and then perform the operation. (For the releasing method, see page 2.)
3
E FS-MC8N/P IM
Page 4
Copyright (c) 2017 KEYENCE CORPORATION. All rights reserved.
14747E 1107-2 96M14747 Printed in Japan

10 Specifications

Model
Number of inputs and outputs
Response time
Unit expansion
Indicators
Separate control output, common output
External input time
Protection circuit
Power supply
Environmental resistance
Case material Main unit and cover: polycarbonate
Weight Approx. 110 g
*1 Match the rated power supply voltage of the expansion units to be connected
to expand the system.
*2 The power consumption including the load when the maximum number of
units are connected is 38 W max.
NPN output FS-MC8N
PNP output FS-MC8P
Separate control output: 8,
common output: 1, common input: 1
Depends on the response time settings of the
connected expansion units
Up to 8 expansion units can be connected.
NPN output
PNP output
Power supply
*1
voltage
Power consumption
Ambient temperature
Vibration resistance
Shock resistance
(However, each dual output type will be treated
Allowable passing current: 1200 mA or less
STATUS indicator (green and red two-color display)
Input time of the connected expansion units
Protection against reverse power connection,
reverse output connection, output overcurrent,
10 to 30 VDC (including 10% ripple (P-P) or less),
690 mW or less (when used as a solitary unit)
(26 mA or less at 24 V/38 mA or less at 12 V
*2
500 m/s
as 2 expansion units.)
MEMORY indicator (orange)
LOCK indicator (orange)
NPN open-collector, 30 V or less,
20 mA or less per output,
residual voltage: 1.4 V or less
PNP open-collector, 30 V or less,
20 mA or less per output,
residual voltage: 1.6 V or less
+11 ms
and output surge
class 2 or LPS
[excluding the load current])
-20°C to +55°C (no freezing)
10 to 55 Hz; double amplitude 1.5 mm;
2 hours each for X, Y, and Z axes
2
; 3 times each for X, Y, and Z axes
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the
foregoing warranty disclaimers or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples.
E 1101-3
E FS-MC8N/P IM
4
Loading...