IC1Panel microprocessorPanel control microprocessor
IC2ROM ICGraphic ROM
IC3Flash ROM ICFor Display customize memory IC
IC4AVRFor 3.3V power supply
IC5AVRFor 2.5V power supply
IC6Buffer ICLevel shift buffer IC (5V→3.3V)
IC7Buffer ICLevel shift buffer IC (3.3V→5V)
IC8Remote control ICFor Remote control sensor
IC9Logic ICControl for FL contrast
IC10Analog ICSpectrum analyzer IC
Q13.3V RegulatorWhile PAN5V is applied when 3.3V regulator output is +3.3V
Q22.5V RegulatorWhile PAN5V is applied when 2.5V regulator output is +2.5V
Q3,4FL +B SWFL +B (VDD1) is turned on when Q3 base level goes H
Q53.3V SWSW3.3V is turned on when Q5 base level goes L
Q6,200FL 3.3V SWFL +3.3V (VDD1) is turned on when Q200 base level goes H
Q7,8Remote control ON SWThe power supply of IC8, 10 is turned on when Q10 base level goes H
Q9FL BLK SWVFD is turned on when Q9 base level goes H
Q10Display blackout LED SWGreen LED is turned on when Q10 base level goes H
Q11Red LED SWRed LED is turned on when Q11 base level goes H
Q1DSI LED SWDSI LED blinks when Q1 base level goes H/L
Q2KEY Illumination SW (Green)KEY Illumination SW “ON” when the Q2 base level goes H
Q3KEY Illumination SW (Red)KEY Illumination SW “ON” when the Q3 base level goes H
Q4KEY Illumination SW (Blue)KEY Illumination SW “ON” when the Q4 base level goes H
IC1Motor driverLoading & Eject motor driver
IC2AVRBU3.3V AVR
IC4AVRSW3.3V AVR (When CNTL is goes H, IC3 is actives)
IC5Mechanism control micro processorIC6PWM driverFocus, Tracking coil, Feed and Spindle motor driver IC
IC7DSPCD signal processor, RF amp, Servo control, MP3 & WMA decoder
IC8EDO DRAMDate buffer (16MB)
IC9AVRAudio 3.3V AVR (When P-ON level goes H, Q12, 13 are turned ON)
IC10LPFAudio LPF
Q1Switching TRWhen MRST goes L, Q1 is turned ON
Q2Switching TRWhen Q1 goes ON, Q2 is turned ON
Q6Switching TRWhen Q7 goes ON, Q6 is turned ON
Q7Switching TRWhen P-On goes H, Q7 is turned ON
Q8APCAuto power control & A 5V constant current circuit
Q9Driver1.6V AVR driver
Q10Switching TRLoading & Eject motor drive voltage selector
Q11Switching TRGuarantee of proper operation for between IC’s Low level voltage
Q12Switching TRWhen Q13 base level goes H, Q12 is turned ON
Q13Switching TRWhen P-On goes H, Q13 is turned ON
IC1System control ICSystem control microprocessor
IC2E-VOL & tuner ICE-VOL. FM/AM tuner & stereo decoder
IC3Power supply ICFor A8V AVR
IC4Audio power ICAudio power amplifier
IC7Power supply IC-9V AVR (For 4.5V Pre-out)
IC8Reset ICWhen BU5V line voltage is less than 3.5V, this IC output line is “L”
IC9Muting logic ICControl for MUTE, P-ANT & RESET muting
IC10Buffer ICFor spectrum analyzer
IC11~13OP AMPFor 4.5V Pre-out
IC14RDS decoderDecode for RDS signal
IC15,16Motor driverControl for Panel mechanism motor
IC18P-CON ICPower control IC
IC19Power supply ICSwitching regulator IC for CD4.7V
IC20Analog SWLogic IC for muting control
Q1,2BU 5V AVRWhile BU is applied when BU5V regulator output is +5V
Q3,601SW5V AVRWhen Q601base level goes H, SW5V regulator output is +5V
Q4,5SW14V AVRWhen Q5 base level goes H, SW14V regulator output is +14V
Q6~8Audio 8V AVRWhen Q6 base level goes H, A8V regulator output is +8.3V
Q9,602Servo +B AVRWhen Q602 base level goes H, S+B regulator output is +7.5V
Q11~14Illumination & DC/DC +B AVRWhen Q11 base level goes H, AVR output is +9.2V
Q15,16Audio 10.5V AVRWhen Q16 base level goes H, AVR output is +10.5V
Q17~19Pre Amp & -9V AVR
Q20~22Pre Amp & +9V AVR
Q23,24P-ANT SWWhen Q23 base level goes H, P-ANT SW output is +14V
Q25BufferEX amp control buffer
Q26Small lamp det. SWWhen Q26 base level goes H, Q26 turned ON
Q27BU detectorWhen Q27 base level goes H, Q27 turned ON
Q29ACC detectorWhen Q29 base level goes H, Q29 turned ON
Q30,31Muting driverWhen base level goes L, muting driver is turned ON
Q32,33Surge DET.When Q32 base level goes H, Q32, 33 are turned ON
Q34Muting driverWhen Q34 base level goes L, muting driver is turned ON
Q201BufferNoise detect buffer amp
Q202E-VOL muting SWWhen Q202 base level goes H, muting SW is turned ON
Q203~208 Pre-out muting SWWhen base level goes H, Pre-output is muted
Q210AGCFor AGC for spectrum analyzer
Q303,304AM +B SWWhen Q303 base level goes H, AM +B is out to tuner unit
Q18, 19 work as differential amplifier, Q17 wark as driver and -9.1V is supplied to OP
AMP for Pre-out
Q20, 22 work as differential amplifier, Q21 wark as driver and +9.4V is supplied to OP
AMP for Pre-out
1CD SDAI/O CD mechanism, IC2, IC5, ROM correction DATA line
2TUN SCLI/O Clock input/ output to Tuner front-end
3RDS AFS MI/O RDS control for MPX PLL hold
4NC-NC
5CD SCLI/O CD mechanism, IC2, IC5, ROM correction CLOCK line
6EVDD-VDD 5V
7EVSS-GND
8RDS AFS LI/O RDS control for MPX PLL hold
9PWIC BEEPOBEEP audio output terminal
10REMOIRemote control input terminal
11BMSOPL2 BMS control terminal (H : BMS ON, L : BMS OFF)
12DSP RQODSP chip select output terminal ( L : Active)
13DSP SIODSP serial data output terminal
14DSP CLKODSP serial data clock output terminal
15DSP CODEC RST OReset for DSP (AD/DA & DSP, L : RESET)
16DSP INT RSTOReset for DSP (System reset, L : RESET)
17DSP MUTEODSP input muting control (L : Mute ON, H : Mute OFF)
18TEST-NC (GND)
19PWIC MUTEOAudio power IC muting control terminal (POWER OFF, ALL OFF, TEL MUTE : L)
20P STBYOAudio power IC Stand-by terminal (POWER IC ON, ALL OFF : H, POWER IC OFF : L)
21P CONI/O Power control terminal (POWER ON : H, POWER OFF, ALL OFF : Hi-Z)
22DIAGIOver voltage/Over current detection terminal (Normal : H, Bad condition : L)
23MUTEOMuting control terminal (ON : OPEN, OFF : L)
24MUTE PRE ROPREOUT (Rch) muting control terminal
25MUTE PRE LOPREOUT (Lch) muting control terminal
26EXT AMP CONTOExternal amplifier control terminal
27BU DETI
28ACC DETIACC detection terminal (With ACC : L, Without ACC : H)
29ILLUMI DETISmall lamp detection terminal (ON : L, OFF : H)
30
31RESETIReset input terminal
32,33XT1/XT2-Sub clock (32.768kHz)
34REGC-Connect to 1u capacitor
35,36X2/X1-Main clock (20MHz)
37VSS-GND
38VDD-AVR 5V
39CLKOUT-NC
40LX REQ MOCommunication request to external slave unit (Request : L)
41LX MUTEIMute request from external slave unit (MUTE : H)
ANT CONT (TYPE2)
Momentary power dropped detection terminal (No Backup, Momentary power dropped : H, Backup : L)
I/O Antenna control/ Destination select terminal (TUNER ON : H)
42LX CONOExternal slave unit (ON : H, OFF : L)
43LX RSTOReset output to external slave unit (Normal : L, After system reset : H 400ms or more and then L)
44P ONI/O SW14V, SW5V control terminal (POWER ON : H, POWER OFF : Hi-Z)
45PON ILLI/O FL, illumination control terminal (ON : H, OFF : Hi-Z)
46PON CDOCD5V output terminal (CD : H, Except CD source : L)
47FAC1OFAC motor driver control terminal (Pulls cycle 16ms)
48NC-NC
49,50TYPE0/TYPE1IDestination select terminal
51PON PANOPanel 5V control terminal (ON : H, Momentary power dropped : Hi-Z)
52DSII/O DSI control (ON : L, OFF : Hi-Z)
53MC REQOCommunication request to panel microprocessor
54PAN RSTOReset output to panel microprocessor (Normal : H, Reset, Momentary power dropped : L)
55DVDD-AVR 5V
56DVSS-GND
57SC CONOPanel microprocessor control terminal (POWER OFF, ACC OFF : L)
58CD MRSTOReset output to CD mechanism (Normal : H, Reset : L)
59CD MSTOPOStop request to CD mechanism (STOP : L, CD : H)
60CD LOE SWICD DOWN SW detection terminal (CD disc chucking : H)
61CD EJECTOCD mechanism loading/ eject control
62CD LOADOCD mechanism loading/ eject control
63FPM MOTOR BOFPM mechanism (Slider) control terminal1
64FPM MOTOR FOFPM mechanism (Slider) control terminal1
65FPM MOTOR OOFPM mechanism (Angle) control terminal1
66FPM MOTOR COFPM mechanism (Angle) control terminal1
67OPEL DATAI/O External display DATA terminal
68OPEL CLKI/O External display CLK terminal
69OPEL CEI/O External display chip enable terminal
70CD MUTE RIMute request from CD mechanism (Rch ON : L)
71AVDD-AVR 5V
72AVSS-GND
73AVREFIConnect to P-ON(45PIN)
74CD MUTE LIMute request from CD mechanism (Lch ON : L)
75PAN DETIPANEL, E2PROM detection terminal (With panel : L, Without : H)
76LINE MUTEIPHONE detection terminal (TEL MUTE : 1V or less, NAVI MUTE : 2.5V or more)
77FPM SW4I
78FPM SW1IFPM mechanism position detect terminal1
79FPM SW2IFPM mechanism position detect terminal1
80FPM SW3IFPM mechanism position detect terminal1
81FPM PHOUTIFPM mechanism position detect terminal (2.2V or more : H)1
FPM mechanism position detect/ CD Mechanism detection terminal (3.75V or more : No mechanism,
82TUN SMETERIS meter detection terminal
83RDS NOISEIFM noise detection terminal
84TUN IFC OUTIFront end IFC OUT input terminal (Receiving station : 2.5V or more)
85PWIC DC DETIAudio power IC DC offset detection (H : OK, L : ERROR)
86CD 8EJEI8cmDISC detection terminal (8cmDISC : L)
87RDS CLKIRDS decoder clock input terminal
88LX REQ SIReceive request from external slave unit (Request : L)
89SC REQICommunication request from panel microprocessor
90CD LOS SWILOADING SW detection terminal (LOADING start, POWER OFF : L)
91CD 12EJEI12cmDISC detection terminal (12cmDISC, POWER OFF : L)
92R QUALIRDS decoder QUAL input terminal
93R DATAIRDS decoder DATA input terminal
94LX DATA SIData input from external slave unit
95LX DATA MOData output to external slave unit
96LX CLKI/O Clock input / output with external slave unit
97PAN RXIData input from panel microprocessor
98PAN TXOData output to panel microprocessor
99PON AMI/O AM+B (AM operation : H)
100TUN SDAI/O Clock input/ output to Tuner front-end
64,65MODE0,1-GND
66PAN RSTIReset signal request form system microprocessor (L : Reset)
67VREF-Connect to 83PIN (VREF)
68,69NC-NC
70,71AVSS1,0-GND
72VREF-Connect to 83PIN (VREF)
73WAVE INIAudio signal input terminal
74F06ISpectrum analyzer input terminal (BPF 10KHz)
75F05ISpectrum analyzer input terminal (BPF 3.3KHz)
76F04ISpectrum analyzer input terminal (BPF 1KHz)
77F03ISpectrum analyzer input terminal (BPF 330Hz)
78F02ISpectrum analyzer input terminal (BPF 150Hz)
79F01ISpectrum analyzer input terminal (BPF 63Hz)
80NC-NC
812.5V VDD-AVR 2.5V
82VSS-GND
83VREF CONOVREF control terminal (Connect to VREF terminal)
84NC-NC
85FLGCP3OFL bright control terminal
86NC-NC
87FL LATCHOLatch output to FL driver IC
88,89NC-NC
90REMO ONOPower supply control for remote control IC (H : ON, Hi-Z : OFF)
91FL3.3V SWOFL3.3V control terminal (H : ON, Hi-Z : OFF)
92FL+B SWOFL+B control terminal (H : ON, Hi-Z : OFF)
933.3V SWO3.3V control terminal (L : ON, Hi-Z : OFF)
94NC-NC
95OEOOE control for Flash ROM (L : DATA transmission, Hi-Z : Wait ready)
96NC-NC
97WE/WROWRITE/READ control for Flash ROM (L : Writing, Hi-Z : Wait ready)
983.3V VDD-AVR 3.3V
99EVSS-GND
100CE ROMOCE control for ROM (L : DATA transmission, Hi-Z : Wait ready)
101CE F/ROMOCE control for Flash ROM (L : DATA transmission, Hi-Z : Wait ready)
102
103,104NC-NC
105GREEN LEDOSelect for illumination (GREEN H : ON, L : OFF)
106RED LEDOSelect for illumination (RED H : ON, L : OFF)
107DISP LEDODISP LED control (Normal H: ON, L : OFF)
108BLACK DISPOLight up to DISP LED (H : ON, L : OFF)
FLASHROM CHECK
OWriting condition check for Flash ROM (H : OK, L : NG)
1AVREF0-Reference voltage to A/D converter
2AVSS-GND (For AD converter)
3SLD1OStepping motor control terminal 1
4SLD2OStepping motor control terminal 2
5AVREF1IReference voltage to D/A converter
6D-MUTEOMUTE driver (L : MUTE ON)
7BMSOBMS MODE (L : R-BRAKE)
8IC/FLMD0-FLASH memory writing voltage output
9VDD-AVR (3.3V)
10REGC-Connect to 1u capacitor
11VSS-GND
12,13X1/X2-System clock
14RESETIReset input terminal (L : RESET)
15~17NC-NC
18MSTOPIInterrupt for Standby mode (L : STOP)
19INTSVIInterrupt for servo IC
20FOGUPIInterrupt for focus gain up (L : NORMAL)
21FOKIFocus condition detect (L : Focus OK)
22E2P_SDAI/O E2P I2C data for ROM correction
23E2P_CLKOE2P I2C clock for ROM correction
24~26NC-NC
27TZCITracking Zero cross input terminal
28LIM_SWIPickup inside detector (L : Inside)
29PONOPower ON/OFF control (L : Power OFF)
30~32NC-NC
33EVSS-GND
34EVDD-VDD
35SYS_SDAI/O System I2C data input / output terminal
36SYS_SCLI/O System I2C clock input / output terminal
37MUTE_LOLch audio mute control (L : MUTE OFF)
38MUTE_RORch audio mute control (L : MUTE OFF)
39PIC_SELIPICKUP selector (L : KCP8C)
40E2P_WRIWriting condition for E2PROM (L : NORMAL)
41ASELIAudio output detector (L : noninverted signal output)
42SHOCK_SELISHOCK PROOF selector (L : Consist in data for buffer memory)
43,44NC-NC
45M_REMOMemory remaining amount monitor output (L : Memory remaining amount less than 75%)
46NC-NC
47~50TEST1-4ITEST MODE1-4
51~57NC-NC
58FG-NC
59DSP_RESETODSP reset control terminal (L : RESET)
60CSOChip select control (L : ON)
61WAITIWAIT control signal detect terminal
62~64NC-NC
65WR0OMultiplex write signal output terminal
66NC-NC
67RDOMultiplex RD signal output terminal
68ASTBOMultiplex ASTB signal output terminal
69BVSS-GND
70BVDD-AVR (3.3V)
71~78AD0~AD7I/O Multiplex address/ data bus
79~83AB8~AB12OMultiplex address/ bus
84~86NC-NC
87ZMUTE_LILch 0bit MUTE detector (L : MUTE OFF)
88ZMUTE_RIRch 0bit MUTE detector (L : MUTE OFF)
89~99NC-NC
100HOTITemperature rise detector (Detect voltage : 2.55V : 95°C, Release voltage : 2.47V : 90°C)
12
TEST MODE
KDC-9026R/PSW9527
KDC-W9027/X979
● How to enter the test mode
While pressing and holding the Preset 1 and Preset 3 keys,
reset the unit.
● How to exit from the test mode
While holding the Preset 6 key, reset the unit.
Note : Turning ACC off, power off, momentary power down
or panel detaching does not terminate the test mode.
● Initial status in the test mode
• Sources : ALL OFF
• Display : All segments are lit.
• Volume : -10dB (displayed as “30”)
• Loudness : OFF
• CRSC : OFF regardless of the presence of switching function.
• SYSTEM Q : Flat
• WOW : All OFF
• BEEP : When pressing any keys, the buzzer generates a
beep at any time.
When any of the following messages is displayed in Tuner
mode, the F/E may be abnormal.
• “TNE2P NG” : The EEPROM is set to the default (unstable
values) because the F/E was shipped without passing
through the adjustment process, etc.
• “TNCON NG” : Comm unication with the F/E is not possible.
● Forced switching of K3I
Each press of the Preset 6 key in Tuner mode should switch
K3I from AUTO→Forced Wide→Forced Middle→Forced
Narrow→AUTO.
The initial status is AUTO and the display shows these
modes as follows.
• AUTO : FMA
• Forced Wide : FMW
• Forced Middle : FMM
• Forced Narrow : FMN
● Test mode specifications of the CD receiver
•Forced ejection is inhibited in the reset start operation. When
the unit is reset while a CD is loaded in it, resetting does
not recognize the CD.
• Each press of the Trac k Up k e y jumps to the f ollo wing tr ac k
numbers :
No. 9→No. 15→No. 10→No. 11→No. 12→No. 13→No. 22→No. 14→No. 9 (The cycle restarts from here.)
• Each press of the Track Down key jumps to the previous
track number to the track being played.
•When the number of total trucks of the MP3 disc or the
WMA disc is less than 9, 1st truck is played.
• When the disc media is CD, A shor t press of the Preset 1
key jumps to the track number 28.
• When the model is equipped the CD mechanism assembly
adapted for MP3 or MP3/WMA disc, the mechanism name
and version number are displayed during the FL model is
lower stand and Display mode of LCD model is DNPS.
●Audio-related specifications (Model KDC-X979/
9026R/PSW9527/W9027)
• Pressing the ✽ key on the remote initiates the audio adjust-
ment mode.
• BL/F key on the Fader initials.
• Continuous holding of a remote control key is inhibited, and
workings are short press of any keys.
• Balance is adjusted in 3 steps of L15 / 0 / R15 with the
Track Up/Down keys (Default value at 0).
• Fader is adjusted in 3 steps of R15 / 0 / F15 with the Track
Up/Down keys (Default value at 0).
• HPF is adjusted in 2 steps of OFF / 170Hz (or 220Hz) with
the Track Up/Down keys (Default value at OFF).
• LPF : (Default value at through).
• Each press of the PRO LOGIG II key should s witch in Bass
management control.
● Menu-related specifications
• A short press of the Q key initiates the menu mode.
• Pressing the DNPP key on the remote initiates the Menu
mode.
• Continuous holding of a remote control key is inhibited, and
workings are short press of any keys.
• Contrast is adjusted in 3 steps of 0 / 5 / 10 with the Track
Up/Down keys (Default value at 5).
13
KDC-9026R/PSW9527
KDC-W9027/X979
TEST MODE
● Backup current measurement
When the unit is reset while ACC is OFF (i.e. by turning
Backup ON), the MUTE terminal goes OFF in 2 seconds in
place of 15 second. (The CD mechanism is not activ ated at
this time.)
● Special display when the display is all on
Pressing the Preset keys while the power is ALL OFF displays the following information.
Version display (8 digits, Month/Day/Hour/Minute)
(Display) SYS xxxxxxxx :
PAN xxxxxxxx : FL model only
MEM
xxxxxxxx :
Serial number display (8 digits)
(Display) SNo xxxxxxxx
Short press : View power ON time. (The All OFF
period is not counted.)
2 seconds long press/hold : Clear power ON time
at the power ON time displaying.
(Display) PonTim xxxxxMax. 60000 (hours)
Short press : Display CD operation time.
2 seconds long press/hold : Clear CD operation
time at the CD operation time displaying.
(Display) CDTim xxxxxMax. 60000 (hours)
Short press : Display CD ejection count.
2 seconds long press/hold : Clear CD ejection
count at the CD ejection count displaying.
(Display) EjeCnt xxxxxMax. 60000 (times)
Short press : Display Panel open/close count.
2 seconds long press/hold : Clear Panel open/close
count at the Panel open/close count.
(Display) PnCnt xxxxxxMax. 600000 (times)
(Display) ROM R xxxInvalid : “R – – –”
(Display) P–ROM OK (Registered code)
P–ROM NG (Code is write in error)
P–ROM WAIT (Unregistered code)
P-ROM NON
(Display) AUDIO INIT
4 contrasts FL model only
(Panel security nonfunctional)
● Panel mechanism
• Auto-panel close inhibition when set-in the CD.
• The panel operation inhibition at power ON/OFF and ACC
ON/OFF.
• The panel position changing Eject→Last with a short press
of the PLAY/PAUSE keys.
● Other specifications
• No displays such as “CODE OFF/ON” during Power-ON.
• The LINE MUTE inhibition time is one second from 10 seconds when start-up the test mode.
• Do not write the security code with the security jig on the
test mode.
• Do not write the serial with the serial writing jig on the test
mode.
• OEM display output is not stop if OEM display not connection on the test mode.
● Switching the frequency span (K/M type)
While holding the Preset 1 key and Preset 5 key, reset the
unit.
●Check the Flash ROM (KDC-X979, KDC-9026R,
KDC-W9027)
1. Display to the following effect at ALL OFF by assortment
system computer and panel for cover the customization
model attach the panel with no Flash ROM.
• Customization system computer + Flash ROM panel : All
lighting
• Non customization system computer + Non Flash ROM panels : All lighting
• Customization system computer + Non Flash ROM panel :
Panel NG
• Non customization system computer + Flash ROM panel :
Panel NG
2. Output (Hi) to the FLASHROM_CHECK terminal on 102
pin when Flash ROM is function properly.
3. Flash ROM data is initialized when pressing the AM key
long hold at all lighting.
Display is “Data Erase .... ” in data erasing mode . Do not touch
anything this mode. When the data erase completed, display is “Erase OK!!”.
If display is “Erase NG!!!!!!”, Flash ROM data unable erase
for some kind or another factors.
When same effect as pressing the AM key long hold and
data erase once again, Flash ROM is defective.
14
TEST MODE
KDC-9026R/PSW9527
KDC-W9027/X979
● Demonstration mode
1. How to enter to the Demonstration mode
1. Hold down the [Q] key and [TI (AME)] key button when the
power is on and press the Reset button.
2. This will enter to the Demonstration mode.
2. How to chancel the Demonstration mode
1. Hold-down the Preset [5] key button when the power is on
and press the Reset button.
2. This will cancel the Demonstration mode.
● Security information
1. Forced Power ON mode (All models)
Even when the security (Cord) is approved, resetting the
unit while holding the Q and Preset 4 keys makes it possible to turn the power ON for 30 minutes.
After 30 minutes have elapsed, it is not possib le to return to
the previous condition unless the unit is reset again. (Security code is doing not clear at this mode. Put the power on
fill-in.)
When panel security was set up for the unit when it is can
not power on.
In this case, you can use new ROM for the TDF panel that
the unit can be power on for test mode.
Note : Don’t enter the panel security set up for new ROM
panel. User can not power on the unit.
2. Method of registration of the security code after
EEPROM (F/E) replacement (Code security model)
1. Enter the test mode. (See How to enter the test mode)
2. Press the MENU key to enter the Menu mode.
3. When the message “Security” is displayed, press and hold
the Track Up/Down key for 1 second to enter the security
registration mode.
4. Enter the code using the FM/AM/T r ack Up/Track Do wn keys .
FM key : Number up
AM key : Number down
Track Up key : Cursor right shift
Track Down key : Cursor left shift
5. Hold down the Trac k Up key for at least 3 seconds and the
message, “RE-ENTER” appears, so once again enter the
code according to Step 4 above.
6. Press and hold the Track Up key for 3 seconds until “APPROVED” is displayed.
7. Exit from the test mode. (See 2. How to exit from the test
mode)
Note 1 : All Clear is not applicable to the security code of
this model.
Note 2 : When the F/E changed, need re-inscription because the panel security is clear.
3. How to inscription the panel security code
1. Enter the test mode.
2. Pressing the AM key on all lighting, check the “P-ROM WAIT”
display.
3. The NEXT key is long press 2 seconds, writing the code.
4. Display is “P-ROM OK”.
5. Exit from the test mode.
Note : E2PROM connection is NG when displa y is “P-R OM
NG”, so detach the panel and rewrite after the display is
“PROM WAIT”. This code can not clear.
4. Simple way to c lear the security code (K type only)
1. During code request mode, press the Track UP key for at
least 3 seconds while holding down the AUTO key. (– – – –
will disappear)
2. Enter, “KCAR” with the remote controller as described below.
• Press the remote controller 5 key twice, and press the T rac k
Up key. (Enters a “K” )
• Press the remote controller 2 key three times, and press
the Track Up key. (Enters a “C” )
• Press the remote controller 2 key once, and press the T r ack
Up key. (Enters an “A” )
• Press the remote controller 7 key twice, and press the T rac k
Up key. (Enters an “R” )
3. Security function is canceled and unit sets to All-Off mode.