IC1System µ-COMSystem controller
IC4Power ICSignal amplifier
IC7Power supply ICDC5Vx1, 7.9x1, 8.1Vx2, 10.2Vx1, P-CON, P-ANT output
IC8Mute logic ICControls for mute operation
IC10E-VOL & TunerE-VOL, tuner, stereo decoder
IC11Reset IC“L”: detection. Voltage is below 3.6V
IC12E2PROMSaves and loads for tuner adjustment data
Q10BU detectionON when the base goes “Hi” during BU is applied
Q20ACC detectionON when the base goes “Hi” during ACC is applied
Q40Mute driver for PRE OUTON when the base goes “Lo”
Q505V SWON when the base goes “Lo”
Q51Control SW for SERVO+BON when the base goes “Hi”
Q53Control SW for IC3ON when the base goes “Hi”. Output voltage is 10.3V
Q55SERVO+B AVROutput voltage is 7.5V
Q70Surge detectionON when the base goes “Hi”
Q102Panel 5V SWON when the base goes “Lo”
Q223Mute SW for Lch PRE OUTPre-output is muted when the base goes “Hi”
Q224Mute SW for Rch PRE OUTPre-output is muted when the base goes “Hi”
Q251IC4 SVR discharge SWON when the base goes “Hi”
Q501AM RF amplifierAdjusts for gain
Q502FM RF amplifierRF amplifier
Generation of RF signal based on the signals from the APC circuit and pickup, and
IC1
RF AMPLIFIER respondinggeneration of servo error (focusing error and tracking error) signals.
to CD-RWDetection of dropout, anti-shock, track crossing and off-tracking conditions, included
Focusing, tracking, sled and spindle servo processing.
IC2
IC34ch BTL DRIVER
IC4LPF (LOW PASS FILTER)2nd low pass filter for audio signals
Q1
Q2DIGITAL +5V SWON when P. ON signal goes “Lo”
Q3Q4 SWON when P. ON signal goes “Lo” (SW+5V is ON)
Q4ANALOG +8V SWON when P. ON signal goes “Lo” (Q3 is ON)
Q5, 6CURRENT AMPCurrent driver
CD SIGNAL PROCESSORAutomatic adjustment (focusing, tracking, gain, offset and balance) operations.
built-in µ-COMDigital signal processing (DSP, PLL, sub-codes, CIRC error correction, audio data
interpolation processing) operations, and microcomputer function.
Focusing coil, tracking coil, spindle motor and sled motor driver, disc loading and
eject operation.
7AVREF18NC-Not used (connected to pin 9)
9IC10-DATAI/O E2PROM communication data for IC10H for no communication
10IC10-CLKO E2PROM communication clock for IC10H for no communication
11L-DATALICommunication data from LCD driver
12L-DATALOCommunication data to LCD driverL-output when panel detached
13L-CLKOCommunication clock to LCD driverL-output when panel detached
14R-DATAICommunication data from RDSL-output for models without RDS
15R-QUALICommunication qualification from RDSL-output for models without RDS
16~18NC-Not used (output L)
19FUNC OUTOFunction output resultH: OK, L: NG
Truth value table
Processing Operation Description
H: Eject completed
Always L-output for models that do not support 8cm CD
H: When panel detached, L: Reset
Normally H, L when Power OFF
H: Select (Panel communication)
L-output when panel detached
H for no communication, L when panel detached
Pull Down at over X34
4
KDC-1032/132/132CR
KDC-133/233/234SGY
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OApplication
20NC-Not used (output L)
21AFSOConstant switching for noise
22~25NC-Not used (output L)
26TYPE REFO5V output for destination settingH: When reading destination
27SDITuner SD inputH: Staion found
28NC-Not used (output L)
29TYPE2IDestination 2q
30TYPE1IDestination 1q
31TYPE0IDestination 0q
32
33VSS134
35MUTEOMute (E-Vol/Pre) control
36M-DATAI/O CD mechanism communication dataH for no communication
37M-CLKOCD mechanism communication clockH for no communication
38ADJOTuner line adjustment
39P-MUTEO Power IC mute control
40SVROPower IC SVR controlH: When reduction of power is detected, L: Normal
41P-STBYOPower IC STBY controlH: Power IC ON, L: Power IC OFF
42SW5VOSW5V control
43B.U-DETIBack Up detectionH: Reduction of power, L: BU found
44ACC-DETIACC detectionH: ACC OFF, L: ACC ON
45PS1-0O
46PS1-1O
47PS1-2OPower IC SW1 control 2 (P-ANT)
48PS2-0OPower IC SW2 control 0 (ILLUMI/FM/AM)
49PS2-1OPower IC SW2 control 1 (ILLUMI/FM/AM)
50BEEPOBeep
51ENC CCWIRotary encoder input
52ENC CWIRotary encoder input
53DSIODSI control
54LOE/LIM SWICD mechanism Down & Limit detectionH: Chucking detection, L: Normal
55MO SWOCD mechanism motor switching SWH: Loading/Eject/Break, L: Play
TUNER-TYPE1
TUNER-TYPE1
IE-VOL setting switchingH: OEM model 1, L: KENWOOD brand model
IE-VOL setting switchingH: OEM model 0, L: KENWOOD brand model
Power IC SW1 control 0
(AUDIO8V/P-CON)
Power IC SW1 control 1
(AUDIO8V/P-CON)
Truth value table
Processing Operation Description
H: Normal, L: FM/AM seek and AF search
(L for Tuner SRC Auto Zero)
H: Mute ON, L: Mute OFF
L in 15 seconds after Power OFF
When ADJ=H, PS1-0,1=L, PS1-2,2-0,1=Hi-z
IC10-DATA, CLK=Hi-z
L: Mute OFF, L: Mute ON
H in 15 seconds after Power OFF
H: SW5V OFF, L: SW5V ON
H in 10 seconds after Power OFF
5
KDC-1032/132/132CR
KDC-133/233/234SGY
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OApplication
56LO/EJI/O CD mechanism Loading/Eject switchingH: Eject, L: Loading
57M-STOPOCD mechanism Stop outputH: CD ON, L: Stop
58M-RSTOCD mechanism Reset outputH: Normal, L: Mechanism reset
59M-MUTEICD mechanism mute inputH: Mute OFF, L: Mute ON
60RESETISystem µ-com reset input
61REMOIRemote controller input
62R-CLKIRDS clock inputL-output for models without RDS
63NC-Not used (output L)
64LOS SWICD mechanism Loading SW detectionH: No DISC, L: DISC IN (Loading start)
● CD MECHANISM µ-COM : IC2 on X32- (CD PLAYER UNIT)
Pin No.Pin NameI/OApplicationProcessing Operation
1TVDOTraverse drive output (PWM output)
2SPLOSpindle motor drive output (PWM output)
3NC-No connection
4PWMOMultipurpose PWM output
5TBALO Tracking balance adjustment output (PWM output)
6FBALO Focusing balance adjustment output (PWM output)
7NRFDETIRF detection signal inputL: Detection
8OFTIOff-tracking signal inputH: Detection
9BDOIDrop-out signal inputH: Detection
10LDONOLaser-on signal outputH: Focus ON
11DSLBODSL balance output
12DVDD1-Power supply for digital circuit
13DVSS1-GND for digital circuit
14AVSS2-GND for analog circuitFor DSL, PLL and A/D converter
15DSLFI/O Loup filter for DSL and bias output for ARF
16ARFIRF signal input
17RFSWIDSL circuit time constant switch
18PLLFI/O Loup filter for PLL
19PLLF2I/O Loup filter character switch for PLL
20IREFIReference current input
21RFENVIRF envelope signal input
22TRCRSITracking cross signal input
23TEITracking error signal input
24FEIFocusing error signal input
25AVDD2-Power supply for analog circuitFor DSL, PLL and A/D converter
26AVSS1-GND for analog circuitFor Lch/Rch audio output
27OUTRO Rch audio output
28AVDD1-Power supply for analog circuitFor Lch/Rch audio output
29OUTLO Lch audio output
30DVSS3-GND for digital circuit
31CSEL32NC-No connection
33ASEL34MSEL035MSEL136~39NC-No connection
40VREFP-Reference power supply input for A/D converter
41HOT428EJE SW-
7
KDC-1032/132/132CR
KDC-133/233/234SGY
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No.Pin NameI/OApplicationProcessing Operation
43
44LOE/LIM SWI
45~49NC-No connection
50DVDD2-Power supply for digital circuit
51X1IMain clock input
52X2OMain clock output
53DVSS2-GND for digital circuit
54XSUB155NC-No connection
56TEST1-Test terminalNormal condition: “H” fixed
57TEST2-Test terminalNormal condition: “H” fixed
58,59NC-No connection
60DRV MUTEODriver mute controlL: Mute ON, H: Mute OFF
61MUTE LOAudio Lch mute output
62MUTE ROAudio Rch mute output
63RSTILSI reset input
64OCD CLK65MSTOPIStandby detection
66DATAI/O
67SBIOIData inputDuring serial writer is connected.
68CLKI/O
69TXODigital audio interface signal output
70NC-No connection
71XSEL72MCNTILoading control / Eject controlL: OFF (Host control), H: Mecha µ-com control
73P. ONOAudio & Servo power supply controlL: Power supply ON, H: Power supply OFF
74,75NC-No connection
76CD-RWO CD-RW controlH: CD-RW, L: Normal disc
77NC-No connection
78DVDD3-Power supply for digital circuit
79FODOFocusing drive output (PWM output)
80TRDOTracking drive output (PWM output)
I2C bus data line (Communication line to system µ-com)
I2C bus clock line (Communication line to system µ-com)
During serial writer is connected.
During serial writer is connected.
8
TEST MODE
KDC-1032/132/132CR
KDC-133/233/234SGY
● How to enter the test mode
• Press Preset [1] and Preset [3] keys simultaneously to reset the unit.
● How to clear the test mode
Reset. (Do not clear by Power OFF and ACC OFF.)
● Initial conditions of the test mode
• Source is STANDBY.
• Displays lights are all turned on.
• The volume is at -10dB (The display is 30).
• CRSC is OFF, regardless of whether there are switching
functions or not.
• LOUD is OFF.
• SYSTEM Q is NATURAL (FLAT).
• BEEP should always work by pressing a key.
● Test mode specification for TUNER
• TUNER (FM) Preset [4] key shall be 98.3MHz.
● CD receiver test mode specifications
•Forced discharging operation is prohibited at reset start. Note
that a CD is not to be recognized by reset when it is inserted.
•[Track up] key triggers a jump to the following tracks.
No. 9 → No. 15 → No. 10 → No. 11 → No. 12 → No. 13 →
No. 22 → No. 14 → No. 9 (recursive)
• [T rack down] key moves back to the previous track from the
current track.
• Preset [1] key triggers a jump to No. 28.
• Preset [2] key triggers a jump to No. 14. (Scan function is
invalid.)
● Audio adjust mode
• Pushing the [VOL] key enters the audio function mode.
• The initial item is Fader. (FAD → BALANCE → BASS →
MID → TRE)
• Use [AM/FM] key to switching items.
• Use [Seek Up/Down] key to switching the adjusted value.
• Adjust Fader/Balance to three levels (15 ↔ 0 ↔ 15) with
Volume up/down. (initial value: 0)
•Adjust Bass/Middle/Treble to three levels (-8 ↔ 0 ↔ +8)
with Volume up/down. (initial value: 0)
• Pressing the [VOL] key for more than a second enters the
audio setup mode.
• Use [AM/FM] key to switching items.
• Use [Seek Up/Down] key to switching the adjusted value.
• Adjust Volume offset to two levels (-8 ↔ 0). (initial value: 0)
• Initialize everything with the [Track-Up] key in the standby
source.
• Pressing [∗] key on the remote controller enters the audio
adjustment mode. (Use [ ∗] k ey to cancel. KDC-132CR only)
• Continuous feed with a remote controller shall not be used.
Pressing a key activates a motion. (KDC-132CR only)
● Special display when all lights are on
The following information will be displayed by pressing the
preset key when STANDBY indicators are on.
[1] key•
[2] key• All LCD light up.
[3] key• Press the key for less than a second: Power-on time
[4] key• Press the key for less than a second: CD operation
[5] key• Press the key for less than a second: CD EJECT
Press [1] key. The current destination SW is displayed.
(Display) TP-X
• Press a key while the destination SW is displayed.
Version display (month, date, hour, minute in 8 digits)
(Display) XXXXxxxx
display (STANDBY time should not be counted).
• Press the key for more than 2 seconds while the
power-on time is displayed: The power-on time is
cleared.
(Display) Pon_xXXXXMAX 60000 (time)
time display.
• Press the key for more than 2 seconds while the CD
operation time is displayed: CD operation time is
cleared.
(Display) PLY_xXXXXMAX 60000 (time)
count display.
• Press the key for more than 2 seconds while the CD
EJECT count is displayed: CD EJECT count is
cleared.
(Display) EJC_xXXXXMAX 60000 (time)
9
KDC-1032/132/132CR
KDC-133/233/234SGY
TEST MODE
[6] key• Press the key for less than a second: PANEL open/
close count display.
• Press the key for more than 2 seconds while the
PANEL open/close count is displayed: PANEL open/
close count is cleared.
(Display) PnL_xXXXXMAX 60000 (time)
[FM] key • ROM correction version display.
(Display)
When valid: RKKK (K: numeric)
When invalid (when unreadable): R– – –
When invalid (when the version is different): Rooo
[AM] key • IC10 adjustment status.
(Display)
Adjustment complete: E2OK
Unadjusted: E2ER
Communication error: ICER
∗ Set Pin 19 to “H” output for E2P OK.
• The detection status is cleared by pressing [TRACKDOWN] key for more than 2 seconds during status
display.
(Display)
When communication OK: ICOK
Communication error: ICER
Not detected: En – – (n: 1~3)
When detected: En∗∗ (∗∗: error code)
[TRACK- • AUDIO data initial value setting
UP] key(Display) INIT
● Backup current measurement
The MUTE terminal turns off in 2 seconds instead of 15
seconds when moved to ACC OFF.
● LCD short check
Switching the process in the following order by pressing [ATT]
key in the STANDBY source.
1. All indicators turn off.
2. Turn on odd terminals and even terminals of the largest
group of segments in every 250m sec.
3. Turn on only odd terminals.
4. Turn on only even terminals.
5. All indicators turn on.
(∗ Return to the first to repeat.)
● Others
•When you star t up the system in test mode, change the
LINE MUTE inhibition time to 1 second from 10 seconds.
● Clearing CD mechanism error information
(E2PROM data clear)
Press [ATT] + [Q] keys to reset (Reset is the only way to
cancel information).
• Memory clear mode display
Display: MCLR
• Memory clear status display (The result of clearing will be
displayed in 2 seconds after startup).
Display
Normal termination: CD_O
Abnormal termination: CD_–
●
FM/AM channel space switching
(only K or M destination models)
Press [1] + [5] keys and [SRC] key simultaneously during
ACC ON/Power OFF.
● IC10 (X34-) stereo adjustment (VCO adjustment)
Press [1] key and [6] ke y simultaneously while all indicators
are on (STANDBY) in test mode.
(Adjusted data will be written on E2PROM)
● Setting for OEM destination
Use pin 2 on the system µ-com terminal to support OEM
model.
TUN TYPE1 TUN TYPE2
(Pin 5)(Pin 6)
LowLowq KENWOOD brand model
HighLoww KENWOOD brand
CRSC changed
LowHighe OEM model with CRSC changed
HighHighr OEM model with CRSC &
De-emphasis changed
Description
model with
10
ADJUSTMENT
1.
IC10 (X34-) -The Tuner adjustment method
• When IC10 and its circumference are repaired, according
to the following order, it readjusts if needed.
• The adjustment item changes with parts to exchange. Please
refer to "Parts vs Adjustment item table".
1-1.
VCO coil adjustment - adjustment of tunning voltage
Voltage Check Point: Vt-Check Land
(PWB Side B, around D506)
Adjustment Coil: L507 (VCO Coil)
The adjustment method : VCO coil is turned and adjusted
Setting of Signal Generator : Refer to the following tables
Type Modefreq.Mod.ANT InputFig.
E/MFM87.5MHzOFF 5 or 11dBµEMF 1~3 (A),(C)
KFM87.9MHzOFF 5 or 11dBµEMF 1~3 (A),(C)
JFM76.0MHzOFF 5 or 11dBµEMF 1~3 (A),(C)
qThe appearance and the coil with which S-METER DC volt-
age serves as the maximum are turned and adjusted in the
above-mentioned SG input.
wBy the above-mentioned adjustment method, same adjust-
ment is performed to both sides (ANT & RF Coil).
M : AM Adjustment
For Your Information : The frequency of this unit is only set
up by preset key in case this adjustment
1-2. Adjustment of 1st & 2nd-MIX coil
Voltage Check Point: S-METER-Check Land
(PWB Side B, around W572)
Adjustment Coil: 1
Setting of Signal Generator : Refer to the following tables
TypeModefreq.Mod.ANT InputFig.
KAM1000kHzOFF35dBµEMF 1~3 (B),(C)
E/M/JAM999kHzOFF35dBµEMF 1~3 (B),(C)
qThe appearance and the coil with which S-METER DC volt-
age serves as the maximum are turned and adjusted in the
above-mentioned SG input.
wBy the above-mentioned adjustment method, same adjust-
ment is performed to both sides (1st & 2nd MIX Coil).
(
REAR VIEW
[Fig.1]
st IFT=L508 / 2nd IFT=L509
)
(
TUNER ANT
)
(A)
FM-SG
(B)
AM-SG
1-4.
Adjustment of STEREO (adjustment of 456k-VCO)
Adjust in TEST MODE
• How to enter the test mode
While pressing on [FM] and Preset [6] keys, reset the unit.
• Adjustment method
Complete on condition that show “STANDBY” when pressing on Preset [1] and Preset [6] keys f or 1 second or more .
(Writing adjustment valve to the E2PROM.)
Effect of adjustment is in cofirmation of adjustment status
at Preset [4] key.