Keithley 2260B-80-13, 2260B-80-27, 2260B-800-1, 2260B-30-72, 2260B-250-9 Quick Start Manual

...
2260B Series
www.keithley.com
Multi-Range Programmable DC Power
Quick Start Guide
/ August 2015
071305502
A Tektronix Company
A Greater Measure of Confidence
ERRATA
Please replace the Accessories section on page 11 through page 13 of the quick start guide with the following replacement:
Accessories
Please check the contents before using the 2260B.
2260B-30/80 Accessories
Standard Accessories
Part number
Description
196353000
Test Leads x1(10AWG, Max. 45A, Max.600V)
174627900
USB Cable
020312300
Basic Accessories Kit:(360W, 720W) M4 terminal screws and washers x2, M8 terminal bolts, nuts and washers x2, Air filter x1, Analog control protection dummy x1, Analog control lock lever x1, Output terminal cover (top & bottom)
020316400
Basic Accessories Kit:(1080W) M4 terminal screws and washers x2, M8 terminal bolts, nuts and washers x2, Air filter x1, Analog control protection dummy x1, Analog control lock lever x1, Output terminal cover (top & bottom), Strain relief
063453401
CD-R 2260B Manuals & Drivers
071305502
Quick Start Guide
PWRKI A*_
Power cord
071305700
China RoHS Declaration
001163200
Calibration of Traceable Certificate
001163300
Packing Check List
Optional Accessories
Part number
Description
2260-001
Accessory Kit:
Pin contact x10, Socket x1, Protection cover x1
2260-002
Simple IDC Tool 2260-003
Contact Removal Tool
2260-004
Basic Accessory Kit:
M4 terminal screws and washers x2, M8 terminal bolts, nuts and washers x2, Air filter x1, Analog control protection dummy x1, Analog control lock lever x1, Output terminal cover (top & bottom), Strain relief
2260-005
Cable for 2 units in Series connection.
2260-006
Cable for 2 units in Parallel connection.
2260-007
Cable for 3 units in Parallel connection.
2260-008
Test Lead Set with Lugs
2260B-EXTERM
Extended terminal
2260B-RMK-JIS
Rack mount adapter (JIS)
2260B-RMK-EIA
Rack mount adapter (EIA)
2260B-GPIB-USB
GPIB to USB adapter
Download
Name
Description
keithley_2260B.inf
USB driver
2260B-250/800 Accessories
Standard Accessories
Part number
Description
196353900
Test Leads x1(20AWG, Max. 9A, Max. 3kV)
174627900
USB Cable
020315700
Basic Accessories Kit: (360W, 720W) Air filter x1, Analog control protection dummy x1, Analog control lock lever x1, Output terminal cover (top & bottom), High voltage output terminal
020316500
Basic Accessories Kit: (1080W) Air filter x1, Analog control protection dummy x1, Analog control lock lever x1, Output terminal cover (top & bottom), High voltage output terminal, Strain relief
063453401
CD-R 2260B Manuals & Drivers
071305502
Quick Start Guide
PWRKI A*_
Power cord
071305700
China RoHS Declaration
001163200
Calibration of Traceable Certificate
001163300
Packing Check List
Optional Accessories
Part number
Description
2260-001
Accessory Kit:
Pin contact x10, Socket x1, Protection cover x1
2260-002
Simple IDC Tool 2260-003
Contact Removal Tool 2260-005
Cable for 2 units in Series connection.
2260-006
Parallel operation cable for 2 units.
2260-007
Parallel operation cable for 3 units.
2260-009
Test Leads (for High Voltage)
2260-010
Basic Accessories Kit: Air filter x1, Analog control protection dummy x1, Analog control lock lever x1, Output terminal cover (top & bottom), High voltage output terminal, Strain relief
2260B-EXTERM­HV
Extended terminal (For 250V/800V HV models)
2260B-RMK-JIS
Rack mount adapter (JIS)
2260B-RMK-EIA
Rack mount adapter (EIA)
2260B-GPIB-USB
GPIB to USB adapter
Download
Name
Description
keithley_2260B.inf
USB driver
Series 2260B
Multi-Range Programmable DC Power Supplies
QUICK START GUIDE
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent.
The information in this manual was correct at the time of printing. However, we continue to improve products and reserves the rights to change specification, equipment, and maintenance procedures at any
time without notice.
Table of Contents
3
Table of Contents
SAFETY INSTRUCTIONS .................................................. 4
GETTING STARTED .......................................................... 8
2260B Series Overview ........................... 8
Appearance .......................................... 15
OPERATION .................................................................. 18
Set Up .................................................. 18
Basic Operation ................................... 19
APPENDIX ..................................................................... 28
2260B Dimensions ............................... 28
2260B Series Quick Start Guide
4
SAFETY INSTRUCTIONS
This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to insure your safety and to keep the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the instrument.
WARNING
Warning: Identifies conditions or practices that could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that could result in damage to the 2260B or to other properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
SAFETY INSTRUCTIONS
5
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
Safety Guidelines
General Guideline
CAUTION
Do not place any heavy object on the 2260B. Avoid severe impact or rough handling that
leads to damaging the 2260B.
Do not discharge static electricity to the 2260B. Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening. Do not disassemble the 2260B unless you are
qualified.
(Measurement categories) EN 61010-1:2010 and EN 61010-2-030 specify the measurement categories and their requirements as follows. The 2260B falls under category II.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Power Supply
WARNING
To avoid electrical shock connect the protective
grounding conductor of the AC power cord to an earth ground.
Cleaning the 2260B
Disconnect the power cord before cleaning. Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
2260B Series Quick Start Guide
6
Operation Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 85% Altitude: < 2000m Temperature: 0°C to 50°C
(Pollution Degree) EN 61010-1:2010 and EN 61010-2-030 specify the pollution degrees and their requirements as follows. The 2260B falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to condensation which is expected. In such conditions, equipment is normally protected against exposure to direct sunlight, precipitation, and full wind pressure, but neither temperature nor humidity is controlled.
Storage environment
Location: Indoor Temperature: -25°C to 70°C Relative Humidity: <90%, no condensation
Disposal
Do not dispose this instrument as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Please make sure discarded electrical waste is properly recycled to reduce environmental impact.
SAFETY INSTRUCTIONS
7
Power cord for the United Kingdom
When using the power supply in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the supplier.
This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used.
Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
Loading...