PARTS MANUAL Gas Furnace N8MSN, N8MSL

Safety Labeling and Signal Words

DANGER, WARNING, CAUTION, and NOTE

The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and throughout this manual and other manuals that may apply to the product.

DANGER − Immediate hazards which will result in severe personal injury or death.

WARNING − Hazards or unsafe practices which could result in severe personal injury or death.

CAUTION − Hazards or unsafe practices which may result in minor personal injury or product or property damage.

NOTE − Used to highlight suggestions which will result in enhanced installation, reliability, or operation.

Signal Words in Manuals

The signal word WARNING is used throughout this manual in the following manner:

!WARNINGWARN G

The signal word CAUTION is used throughout this manual in the following manner:

!CAUTION

Signal Words on Product Labeling

Signal words are used in combination with colors and/or pictures on product labels.

TABLE OF CONTENTS

MODEL NUMBER IDENTIFICATION GUIDE . . . . . . . . 2 PARTS DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

MODELS

N8MSN0451408A1 . . . . . . . . . . . . . . N8MSL0451408A1 N8MSN0451412A1 . . . . . . . . . . . . . . N8MSL0451412A1 N8MSN0701408A1 . . . . . . . . . . . . . . N8MSL0701408A1 N8MSN0701412A1 . . . . . . . . . . . . . . N8MSL0701412A1 N8MSN0701716A1 . . . . . . . . . . . . . . N8MSL0701716A1 N8MSN0901714A1 . . . . . . . . . . . . . . N8MSL0901714A1 N8MSN0902116A1 . . . . . . . . . . . . . . N8MSL0902116A1 N8MSN0902120A1 . . . . . . . . . . . . . . N8MSL0902120A1 N8MSN1101712A1 . . . . . . . . . . . . . . N8MSL1101712A1 N8MSN1102116A1 . . . . . . . . . . . . . . N8MSL1102116A1 N8MSN1102122A1 . . . . . . . . . . . . . . N8MSL1102122A1 N8MSN1352116A1 . . . . . . . . . . . . . . N8MSL1352116A1 N8MSN1352422A1 . . . . . . . . . . . . . . N8MSL1352422A1 N8MSN1552420A1 . . . . . . . . . . . . . . N8MSL1552420A1

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to turn off electric power could result in personal injury or death.

Before installing or servicing system, turn off main power to the system. There may be more than one disconnect switch, including accessory heater(s).

Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org .

441 03 1402 00 Nov. 2012

PARTS MANUAL

 

 

 

 

 

 

 

 

 

Gas Furnace: N8MSN, N8MSL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL NUMBER IDENTIFICATION GUIDE

 

 

 

 

 

DIGIT POSITION

1

2

3

 

4

5

 

6,7,8

 

9,10

11,12

13

14

 

 

 

N

8

M

 

S

L

 

045

 

14

12

A

1

 

N = Entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 = 80% AFUE

EFFICIENCY

 

 

 

 

 

 

 

 

 

 

 

 

M = Multiposition

 

POSITION

 

 

 

 

 

 

 

 

 

 

V = Variable Speed Blower Motor − ECM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X = ECM Blower Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Single−stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T = Two−stage

 

 

 

 

TYPE

 

 

 

 

 

 

 

 

 

N = Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L = Low NOx

 

 

 

 

FEATURE

 

 

 

 

 

 

 

045 = 44,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

070 = 66,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090 = 88,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 = 110,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

135 = 132,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

155 = 154,000 BTU/hr

 

 

 

 

 

 

HEAT INPUT

 

 

 

 

 

14

= 14−3/16”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

= 17−1/2”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

= 21”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

= 24−1/2”

 

 

 

 

 

 

 

CABINET WIDTH

 

 

 

 

08

= 800 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

= 1200 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

= 1400 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

= 1600 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

= 2000 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

= 2200 CFM

 

 

NOMINAL MAXIMUM COOLING AIRFLOW @ .5 IN. W.C.

 

 

 

SALES (MAJOR) REVISION DIGIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGINEERING (MINOR) REVISION DIGIT

 

 

 

 

 

 

 

 

 

 

 

 

 

ECM-Electronically Commutated Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORIES PART NUMBER IDENTIFICATION GUIDE

 

 

 

 

DIGIT POSITION

 

 

 

1

2

 

3

 

4

5, 6, 7

8, 9

10, 11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

A

 

H

 

A

001

01

DH

 

N = Non−Branded

 

 

 

BRANDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Accessory

 

 

 

PRODUCT GROUP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H = Heating

 

 

 

 

 

 

KIT USAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Original

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = 2nd Generation

 

 

 

 

 

 

 

MAJOR SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Identifier Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Package Quantity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of Kit (Example: DH = Draft Hood − Chimney Adapter)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

441 03 1402 00

International Comfort Products N8MSN0451408A1, N8MSL0451408A1, N8MSN0451412A1, N8MSL0451412A1, N8MSN0701408A1 User Manual

PARTS MANUAL

Gas Furnace: N8MSN, N8MSL

 

 

PARTS DIAGRAM

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not

include all components shown.

 

 

 

 

2

A

 

 

 

 

 

 

 

 

 

 

BB

 

 

 

 

 

 

 

AA

 

 

 

 

CC

 

1

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

9

 

18

X

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

Z

 

 

 

 

 

 

 

 

 

27 28

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

D

 

 

 

20

DD

 

 

 

 

 

 

B

 

E

 

 

 

 

G

 

 

 

 

 

C

 

 

LL

 

 

 

 

 

 

N

K

 

7

 

3

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VV

 

 

 

 

 

6

 

 

 

EE

 

J

H

5

 

 

 

 

 

HH

FF

19

441 03 1402 00

3

Loading...
+ 4 hidden pages