HP SN8000B Installation Instructions Manual

Page 1
HP Director Blade Installation Instructions
Overview
Table 1 (page 1). Install the blades in compatible
director models only.
NOTE: This document refers to blades by their
short names.
Table 1 Director blades
Short name
Compatible HP director
models
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
8Gb 32-port Enhanced Fibre Channel Blade
8Gb 48-port Enhanced Fibre Channel Blade
16Gb 32-port Fibre Channel Blade
(imprinted
on blade)Model
FC16-32HP SN8000B
Part
number
QW940AFC8-32EHP SN8000B
QW941AFC8-48EHP SN8000B
QK713A QK713B
© Copyright 2011–2012 Hewlett-Packard Development Company, L.P. Printed in the US
Published: June 2012 Edition: 6
*5697-2056*
16Gb 48-port Fibre Channel Blade
Director Switch 10/24 FCoE blade
nl
option
Director Switch
nl
Multi-protocol
nl
Extension blade option
nl
Director
nl
Encryption blade
Director
nl
16-port 4Gb FC blade
FC16-48HP SN8000B
QK714A QK714B
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
FCOE10-24HP DC SAN
AP866A AP866B
FX8-24HP DC SAN
AP865A AP865B
DC SAN Backbone
nl
Director,
nl
DC04 SAN Director
DC SAN Backbone
nl
Director,
nl
DC04 SAN Director,
nl
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
FS8-18HP DC SAN
AR945A AR945B
DC SAN Backbone Director,
nl
DC04 SAN Director,
nl
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
FC4-16HP SAN
A7990A A7990B
2/128 SAN Director, 4/256 SAN Director
Page 1
Page 2
Director
nl
48-port 4Gb FC blade
Director
nl
32-port 4Gb FC blade
FC4-48HP SAN
4/256 SAN DirectorAG561A
AG561B
Identifying blade components
This section identifies the blade components.
FC4-32HP SAN
A7991B
4/256 SAN DirectorA7991A
NOTE: Ports are numbered from bottom to
top.
FC8-16HP SAN
Director
nl
16-port 8Gb FC blade DC04 SAN Director
FC8-32HP SAN
Director
nl
32-port 8Gb FC blade
FC8-48HP SAN
Director
nl
48-port 8Gb FC blade
FC8-64HP DC SAN
Director
nl
64-port 8Gb
AK858A AK858B AK858C
AK859A AK859B AK859C
AK860A AK860B AK860C
BK798A BK798B
Fibre Channel Blade
4/256 SAN Director, DC SAN Backbone Director,
nl
DC SAN Backbone Director,
nl
DC04 SAN Director
DC SAN Backbone Director,
nl
DC04 SAN Director
DC SAN Backbone
nl
Director,
nl
DC04 SAN Director,
nl
SN8000B 8-Slot SAN Backbone Director, SN8000B 4-Slot SAN Director
AK861A AK861B
Director
nl
6-port 10Gb FC
FC10-6HP SAN
blade DC04 SAN Director
4/256 SAN Director, DC SAN Backbone Director,
nl
FC8-32E components
Figure 1 FC8-32E
iSCSI
nl
Director blade
nl
Multi-protocol (MP) Router blade
FC4-16IPHP B-series
4/256 SAN DirectorAG671A
AG671B
FR4-18iHP B-series
AG461A AG461B
4/256 SAN Director,
nl
DC04 SAN Director
2. Status LED1. Power LED
4. Port and trunking group map3. FC ports 24–31
6. FC ports 0–75. FC ports 16–23
7. FC ports 8–15
Page 2
Page 3
FC8-48E components
FC16-32 components
Figure 2 FC8-48E
Figure 3 FC16-32
2. Status LED1. Power LED
4. FC ports 0–233. FC ports 24–47
2. FC ports 8–151. Power LED
4. Port status LED3. FC ports 0–7
6. Port and trunking group map5. FC ports 24–31
7. FC ports 16–23
Page 3
Page 4
FC16-48 components
FCOE10-24 components
Figure 4 FC16-48
Figure 5 FCOE10-24
2. 10-GbE FCoE ports 0–111. Power LED
4. 10-GbE FCoE ports 12–233. Status LED
2. FC ports 0–231. Power LED
4. FC ports 24–473. Status LED
Page 4
Page 5
FX8-24 components
FS8-18 components
Figure 6 FX8-24
Figure 7 FS8-18
7. FC ports 6–11
2. 1 GbE ports 0–31. Power LED
4. FC ports 0–53. 10-GbE ports 0–1
6. 1 GbE ports 4–95. Status LED
2. Status LED1. Power LED
4. Port status LED3. FC port
5. FC ports 0–15
Page 5
Page 6
FC4-16 components
FC4-32 components
Figure 8 FC4-16
Figure 9 FC4-32
2. Status LED1. Power LED
4. Port speed LED3. FC Port
6. FC ports 0–155. Port status LED
2. Status LED1. Power LED
4. Port speed LED (left port)3. FC Port
6. Port speed LED (right port)5. Port status LED (left port)
8. FC ports 16–317. Port status LED (right port)
9. FC ports 0–15
Page 6
Page 7
FC4-48 components
FC8-16 components
Figure 10 FC4-48
Figure 11 FC8-16
2. Status LED1. Power LED
4. Port status LED3. FC Port
6. FC ports 0–235. FC ports 24–47
2. Status LED1. Power LED
4. Port status LED3. FC Port
5. FC ports 0–15
Page 7
Page 8
FC8-32 components
FC8-48 components
Figure 12 FC8-32
Figure 13 FC8-48
2. Status LED1. Power LED
4. Port status LED3. FC Port
6. FC ports 0–155. FC ports 16–31
2. Status LED1. Power LED
4. Port status LED3. FC Port
6. FC ports 0–235. FC ports 24–47
Page 8
Page 9
FC8-64 components
FC10-6 components
Figure 14 FC8-64
Figure 15 FC10-6
2. Power LED1. Status LED
4. Port status LED3. FC Port
6. FC Port5. FC Port
8. FC ports 0–317. FC ports 32–63
NOTE: FC8-64 supports mini-SFPs (mSFPs)
only.
2. Status LED1. Power LED
4. Port status LED3. FC port
5. FC ports 0–5
Page 9
Page 10
FC4-16IP components
FR4-18i components
Figure 16 FC4-16IP
Figure 17 FR4-18i blade
2. Status LED1. Power LED
4. Port status LED3. FC Port
6. FC ports 0–155. GbE ports 0–1
2. Status LED1. Power LED
4. Port status LED3. FC Port
6. GbE ports 0–75. FC ports 0–7
Page 10
Page 11
Verifying installation requirements
The installation takes less than 10 minutes. You will need the following items:
Replacement director blade
Filler panel for each empty slot (ships with the
director blade)
Electrostatic discharge (ESD) grounding strap
Workstation computer
Phillips screwdriver
Small form-factor pluggable (SFP) transceivers, as
needed (must be ordered separately)
Quad SFP (QSFP) transceivers, as needed (must
be ordered separately)
Extended form-factor pluggable (XFP) transceivers,
as needed, for the FC10-6 only
Optical cables, as needed
Transceiver support
1. Push in the yellow tab on each ejector.
2. Open both ejectors and remove the filler panel. To remove a filler panel with pull tabs:
1. Unscrew the top and bottom captive screws on the filler panel.
2. Grasp the top and bottom pull tabs and remove the filler panel.
Figure 18 Removing filler panels
The FC8-64 supports mSFPs only, and is shipped
with them installed.
Except for the FC8-64, all 8 Gb and 16 Gb
blades use B-series SFPs.
CR16-8 and CR16-4 use QSFP transceivers for
ICL connections.
For more information about supported transceivers, see the HP SPOCK website at http://www.hp.com/
storage/spock. You must sign up for an HP Passport
to gain access. For information on SAN compatibility, see http://
www.hpsancompat.com/.
Removing the filler panel
Remove the filler panel, if installed. There are three filler panel types (Figure 18 (page 11)).
CAUTION: Remove a filler panel only when
installing or replacing a Director blade. All slots that are not occupied by a Director blade require a filler panel to ensure cooling of the chassis and protection from dust.
2. Captive screws (2)1. Filler panel with handle
4. Filler panel with ejectors3. Handle
6. Captive screws (2)5. Ejectors (2)
8. Filler panel with pull tabs7. Pull tabs (2)
Determining the ejector type
Installation procedures vary depending on the ejector mechanism on the blade. This section identifies the blades that use ejectors and sliders, and the blades that use ejectors only.
To remove a filler panel with a handle:
1. Unscrew the two captive screws on the filler panel.
2. Grasp the handle and remove the filler panel.
To remove a filler panel with ejectors:
Page 11
Page 12
Blades with ejectors and slider switches
The following blades use both ejectors and slider switches:
FC4-16IPFC4-16
FR4-18iFC4-32
FC10-6
Blades with ejectors
The following blades use ejectors only:
FC8-48EFC8-32E
FC8-48FC16-32
FC8-64FC16-48
FC4-48FCOE10-24
FS8-18FC8-16
FX8-24FC8-32
4. Proceed to Step 5 if the blade you are installing uses ejectors only. (See “Determining the ejector
type” (page 11).)
For blades with both ejectors and slider switches: a. Open the ejectors approximately 45 degrees,
align the flat side of the blade inside the upper and lower rail guides in the slot, and then, while applying slight pressure to the left, slide the blade into the slot (Figure 19 (page 12)).
Figure 19 Removing and replacing a Director blade with ejectors and slider switches (FC4-16 shown)
Installing the blade
CAUTION: Wear an ESD grounding strap
when handling the blade. On the director chassis, the grounding connection is located above the power connectors.
To install the blade:
1. Identify the ejector type for your blade, as described in “Determining the ejector type” (page
11).
2. Locate an appropriate slot. Slots are numbered from left to right when facing the port side of the chassis.
For the HP 4/256 SAN Director: Install the blades in slots 1 through 4 and 7 through 10.
For the HP DC SAN Backbone Director: Install the blades in slots 1 through 4 and 9 through 12.
For the HP DC04 SAN Director: Install the blades in slots 1 and 2 and slots 7 and 8.
For the HP SN8000B 8-Slot SAN Backbone Director: Install the blades in slots 1 through 4
and 9 through 12. For the HP SN8000B 4-Slot SAN Director: Install
the blades in slots 1 and 2 and slots 7 and 8.
3. Orient the blade so that the ports face outward (away from the slot) and the flat (noncomponent) side is on the left.
2. FC4-161. 4/256 SAN Director
chassis
4. Ejectors (2)3. On/Off slider switch
b. Close the ejectors by pushing the handles
toward the center of the blade until the ejectors lock.
The levering action of the handles seats the blade in the slot.
c. Tighten the thumb screw inside each handle
using the Phillips screwdriver.
d. Turn the blade on by sliding up the slider
switch in the top ejector, covering the thumb screw.
e. Proceed to Step 6.
Page 12
Page 13
5. For blades with ejectors: a. Open the ejectors. b. Align the flat side of the blade inside the
upper and lower rail guides in the slot.
c. Slide the blade into the slot until it is firmly
seated (Figure 20 (page 13)).
d. Close the ejectors.
Figure 20 Removing and replacing a blade with ejectors only (FC4-48 shown)
procedures (including those for mixed-blade configurations), see the following:
HP B-series SN8000B 8-Slot SAN Backbone
Director Switch Hardware Reference Guide
HP HP B-series SN8000B 4-Slot SAN Director
Switch Hardware Reference Guide
HP StorageWorks DC and DC04 SAN Director
Switch Hardware Reference Guide
iSCSI Gateway Service Administrator Guide
Brocade Fabric OS Administrator's Guide
Supporting Fabric OS 7.0.x
For the latest documentation and firmware releases, see:
http://www.hp.com/go/san
2. FC4-481. SAN Backbone Director
chassis
3. Ejectors
6. Verify that the blade power LED is displaying a steady green light and that the blade is firmly seated.
7. Install the transceivers and cables.
For more information
This document provides initial setup and configuration procedures only. For comprehensive configuration
Page 13
Loading...