Hilti PSA 80, PUA 80, PSA 83, PUA 81, PUA 82 Operating Instructions Manual

...
PSA / PUA
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01
English
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01

1 Information about the documentation

1.1 About this documentation

• Observe the safety instructions and warnings in this documentation and on the product.
• Always keep the operating instructions with the product and make sure that the operating instructions are with the product when it is given to other persons.

1.2 Explanation of signs used

1.2.1 Warnings

Warnings alert persons to hazards that occur when handling or using the product. The following signal words are used in combination with a symbol:
DANGER! Draws attention to imminent danger that will lead to serious personal injury or fatality.
WARNING! Draws attention to a potential hazard that could lead to serious personal injury or
fatality.
CAUTION! Draws attention to a potentially dangerous situation that could lead to slight personal injury or damage to the equipment or other property.

1.2.2 Symbols

The following symbols are used:
Read the operating instructions before use.
Instructions for use and other useful information
Protection class II (double-insulated)
For indoor use only

1.2.3 Illustrations

The following symbols are used in illustrations:
These numbers refer to the corresponding illustrations found at the beginning of these operating instructions.
Item reference numbers are used in the overview illustration and refer to the numbers used in the product overview section.

1.3 Product information

Hilti products are designed for professional use and may be operated, serviced and maintained only by
trained, authorized personnel. This personnel must be informed of any particular hazards that may be encountered. The product and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not as directed.
Make a note in one of the following tables of the designation and serial number printed on the type
identification plate.
Always quote this information when you contact a Hilti representative or Hilti Service to enquire about
the product.
PSA 80, PSA 81, PSA 82 and PSA 83 product information
Battery PSA 80
PSA 81 PSA 82 PSA 83
Generation 01
Serial no.
English 1
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01
***** For internal use only ***** 18.08.2016 / 09:08:15 - H2\DOK-Projekt\System\PSA 80_81_82_85\ENU\PSA_PUA
PSA 81 Product information
Battery PSA 81
Generation 02
Serial no.
PSA 81 Product information
Battery PSA 81
Generation 05
Serial no.
PSA 85, PUA 80 and PUA 85 19V product information
Charger PSA 85
PUA 80 PUA 85 19V
Generation 01
PUA 81 Product information
AC adapter PUA 81
Generation 01
PUA 82 Product information
Motor vehicle power
PUA 82
adapter
Generation 01

1.4 Declaration of conformity

We declare, on our soleresponsibility, that the productdescribed here complies with the applicable directives and standards. A copy of the declaration of conformity can be found at the end of this documentation.
The technical documentation is filed and stored here:
Hilti Entwicklungsgesellschaft mbH | Tool Certification | Hiltistraße 6 | 86916 Kaufering, DE

2 Safety

2.1 Additional safety instructions

Personal safety
Modification of the tool is not permitted.Do not use force when inserting the batteries in the tool.The tool is not intended for use by debilitated persons who have received no special training. Keep the
tool out of reach of children.
Store tools in a secure place when not in use. When not in use, tools must be stored in a dry, high place
or locked away out of reach of children.
Ensure that the tool and the AC adapter do not present an obstacle that could lead to a risk of tripping
or personal injury.
Do not expose the supply cords to heat, oil or sharp edges.Never operate the appliance when it is dirty or wet. Dust (especially dust from conductive materials)
or dampness adhering to the surface of the appliance may, under unfavorable conditions, lead to electric shock.
Remove the battery if the tool is to remain unused for a long period of time.
Electrical
Although the device complies with the strict requirements of the applicable directives, Hilti cannot
entirely rule out the possibility of interference to the device caused by powerful electromagnetic radiation, possibly leading to incorrect operation.
Cleaning and drying the tool
Clean the tool with a clean, soft cloth. If necessary, moisten the cloth slightly with pure alcohol or a little
water.
***** For internal use only ***** 18.08.2016 / 09:08:15 - H2\DOK-Projekt\System\PSA 80_81_82_85\ENU\PSA_PUA
Do not use any liquids other than pure alcohol or water as these may damage the plastic components.
2 English
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01

2.2 Use and care of battery-powered tools

Use only the Hilti batteries specified for use with this product.Observe the special guidelines applicable to the transport, storage and use of Li-ion batteries.Check that the product is switched off before fitting the battery.Do not expose batteries to high temperatures, direct sunlight or fire.Do not disassemble, crush or incinerate batteries and do not subject them to temperatures over 75°C
(167°F).
Do not attempt to charge or continue to use damaged batteries.If the battery is too hot to touch it may be defective. In this case, place the tool in a non-flammable
location, well away from flammable materials, where it can be kept under observation and allowed to cool down. Contact Hilti Service after the battery has cooled down.
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01
English 3
***** For internal use only ***** 18.08.2016 / 09:08:15 - H2\DOK-Projekt\System\PSA 80_81_82_85\ENU\PSA_PUA

3 Description

3.1 Accessories

***** For internal use only ***** 18.08.2016 / 09:08:15 - H2\DOK-Projekt\System\PSA 80_81_82_85\ENU\PSA_PUA
Battery PSA 81
@
4 English
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01
AC adapter PUA 81
;
Battery PSA 82
=
Charger PSA 85
%
Battery PSA 83
&

3.2 Intended use

Use the PSA 80 only to power the Hilti PS 200 S Ferroscan and the PS 200 M monitor. Charge the PSA 80 battery with the PUA 80 charger.
Use the PSA 81 battery only to power the Hilti PS 1000 X-Scans. Charge the PSA 81 (01 and 02) battery only with the PUA 81 AC adapter or the PUA 82 motor vehicle power adapter. Charge the PSA 81 (05) with the PUA 85 19V charger or the PUA 81 AC adapter.
Use the PSA 82 battery to power the Hilti PSA 100 monitor. Charge the battery in the tool using the PUA 81 AC adapter or the PUA 82 motor vehicle power adapter. Alternatively, you can use the PSA 85 charger to charge the PSA 82 battery when it is not in the tool.
Use the PSA 83 battery to power the Hilti PSA 200 tablet. Use the PUA 85 19V charger to charge the battery while fitted.
Use the PSA 85 charger to charge the PSA 82 battery. Use the PUA 80 charger to charge the PSA 80 battery. Use the PUA 81 AC adapter to charge the PSA 81 (01, 02 and 05) battery, the PSA 82 battery when it is in
the PSA 100 monitor (when switched off or in operating mode) and the PRA 84 battery. Use the PUA 82 motor vehicle power adapter to charge the PSA 81 (01, 02 and 05) battery, the PSA 82
battery when it is in the PSA 100 monitor (when switched off or in operating mode) and the PRA 84 battery. Use the PUA 85 19V charger to charge the PSA 81 battery (01, 02 and 05) and to charge the PSA 83 battery
in the PSA 200 tablet.

3.3 Foreseeable faults

Do not use the battery as a power source for other unspecified appliances. Do not use the device where there is a risk of fire or explosion.

3.4 Charging status display on the PUA 80 charger

PUA 80
PUA 82 motor vehicle power adapter
(
Charger PUA 85 19V
)
Battery PSA 80
+
Status Meaning
1 LED lights red. • The battery is charging.
LED 1 blinks red • The battery is fully charged.
1 LED lights green. • The charger or the battery is not in working
order.
LED 1 blinks green • The battery is not charging.

3.5 Battery charge status indicator PSA 81

PSA 81
Status Meaning
4 LEDs light green. • State of charge: 75 % to 100 %
3 LEDs light green. • State of charge: 50 % to 75 %
2 LEDs light green. • State of charge: 25 % to 50 %
1 LED lights green. • Charge status: < 25 %
1 LED lights red. • Error
Note
The fault may be remedied by charging the battery. If charging does not remedy the fault, the battery must be replaced.
English 5
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01
***** For internal use only ***** 18.08.2016 / 09:08:15 - H2\DOK-Projekt\System\PSA 80_81_82_85\ENU\PSA_PUA
The error message can have the following causes:
• Voltage too high
• Short circuit
• Voltage too low
• Temperature is outside the charging temperature range
• Wrong charger is connected
• Electronic fault
While charging, the LEDs show the following statuses:
Status Meaning
3 LEDs light, 1 LED blinks. • State of charge: 75 % to 100 %
2 LEDs light, 1 LED blinks. • State of charge: 50 % to 75 %
1 LED lights, 1 LED blinks. • State of charge: 25 % to 50 %
1 LED blinks. • Charge status: < 25 %
Note
The PSA 81 (01 and 02) battery may be charged only with the PUA 81 AC adapter. The PSA 81 (05) battery can be charged either with the PUA 81 AC adapter or the PUA 85 19V charger.

3.6 PSA 82 battery charging status display on the PSA 100 monitor

PSA 82
PUA 81
The charging LED can have the following statuses:
Status Meaning
1 LED lights green. • The battery is fully charged.
LED 1 blinks green • The battery is charging
No LED lights while in operating mode • The battery is discharging.

3.7 Charging status display on the PSA 82 battery when charging with the PSA 85 charger

PSA 82
PSA 85
The charging LED can have the following statuses:
Status Meaning
1 LED lights green. • The battery is fully charged.
1 LED lights orange. • The battery is charging.
1 LED lights red. • State of charge: < 25 %

4 Technical data

4.1 Battery technical data

PSA 80 PSA 81 (01 and 02) PSA 81 (05)
Type
Rated voltage
Operating voltage
Input voltage
Capacity
Charging time
IP protection class
***** For internal use only ***** 18.08.2016 / 09:08:15 - H2\DOK-Projekt\System\PSA 80_81_82_85\ENU\PSA_PUA
Operating temperature
Storage temperature (dry)
NiMH Liion Liion
9.6 V 7.4 V 7.4 V
•/• 6 V …8.4 V 6.5 V …8.4 V
•/• 12 V 12 V …19 V
200 mAh 5,200 mAh 5,000 mAh
3 h 3 h 3 h
54 56 56
0 ℃ …40 ℃ −15 ℃ …50 ℃ −20 ℃ …50 ℃
•/• −25 ℃ …60 ℃ −20 ℃ …50 ℃
6 English
Printed: 19.08.2016 | Doc-Nr: PUB / 5070470 / 000 / 01
Loading...