Installation & Operating Manual
The Harman Clarity 929BV Gas Stove
“Ce manuel est disponible en Français sur demande” |
R5 |
SAFETY NOTICE
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
Contact your local authority (such as municipal building department, fire department, fire prevention bureau, etc.) to determine the need for a permit.
Cette guide d'utilisation est disponible en francais. Chez votre concessionnaire de Harman Stove Company.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire department.
save these instructions.
Table of Contents |
|
INTRODUCTION............................................................ |
3 |
INSTALLATION.............................................................. |
4 |
Clearances.................................................................. |
4 |
Venting........................................................................ |
5 |
Test for Flue Spillage................................................. |
5 |
Assembly.................................................................... |
6 |
Connecting to a Gas Supply....................................... |
8 |
Connecting the Cordset and Thermostat.................... |
9 |
Air Shutter Adjustment............................................. |
10 |
Monitoring the Gas Flame........................................ |
10 |
OPERATION.................................................................. |
11 |
How to Light the Fire............................................... |
11 |
How to Turn Off the Fire.......................................... |
11 |
Lighting Instructions................................................ |
11 |
Maintenance........................................................... |
12 |
Removing the Glass.................................................. |
12 |
Replacing the Gasket................................................ |
12 |
Cleaning the Glass.................................................... |
12 |
Inspecting the Venting.............................................. |
12 |
Cleaning the Logset and Firebox.............................. |
12 |
Wiring Diagram........................................................ |
13 |
PARTS LIST & DRAWING...................................... |
14-15 |
BURNER MODULE EXPLODED VIEW..................... |
16 |
APPENDIX A: FUEL CONVERSION.......................... |
17 |
APPENDIX B: ALTITUDE DE-RATING .................... |
18 |
SPECIFICATIONS ........................................................ |
19 |
WARRANTY.................................................................. |
20 |
Manufactured by: |
Tested by. |
Harman Stove Co. |
Intertek Testing/Warnock Hersey |
352 Mountain House Road |
8431 Murphy Drive |
Halifax, PA 17032 |
Middleton, WI 53562 |
Introduction
The Harman Clarity 929BV Vented Gas Heater is a listed gas-fired vented room heater tested by Intertek
Testing/Warnock Hersey to ANSI standard Z21.882002, CSA 2.33-M02, and CAN/CGA-2.17-M91.
The installation of the Clarity Vented Gas Heater must conform with local codes, or in the absence of local codes, with the current edition of National Fuel Gas Code, ANSI Z223.1 — latest edition and CAN 1-B1-149.1 and .2 Installation Code.
The Clarity 929BV is not for use in mobile homes. CAUTION: This appliance must be vented to the
outside.
Installation and repair of the Clarity Vented Gas
Heater should be done by a qualified service person.
The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the Clarity be kept clean.
When operating your Harman Clarity Gas Heater, respect basic safety standards. Read these instructions carefully before you attempt to operate the heater. Failure to do so may result in damage to property or personal injury and may void the product warranty.
Consult with your local building code agency and insurance representative before you begin your installation to ensure compliance with local codes, including the need for permits and follow-up inspections.
Several issues must be addressed when selecting a suitable location for your Clarity Gas Heater. Observing required clearances to combustible materials, the proximity to a safe chimney or venting system,and the accessibility of the gas and electrical supply must all be considered. In addition, selecting a location that takes advantage of the building's natural air flow is also desirable to maximize the heating effectiveness of the heater. In many cases, this is a central location within the building.
Adequate combustion and ventilation air must be provided.
Due to high temperatures, the Clarity Vented Gas
Heater should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the Clarity
Vented Gas Heater. Clearance from corner of unit to walls
Clothing or other flammable materials should not be placed on or near the Clarity Vented Gas Heater.
Installation
CLEARANCES
The following clearances to combustibles must be
observed: |
|
|
Unit to left sidewall |
9" |
(230 mm) |
Unit to right sidewall |
9" |
(230 mm) |
Unit corner to walls |
4" |
(100 mm) |
Rear of unit to back wall |
3" |
(75 mm) |
(measured from rear of draft hood to wall) |
|
|
Unit to alcove ceiling |
18" |
(460 mm) |
Maximum alcove depth |
14" |
(355 mm) |
Sidewall Clearance
Clearance to Back wall
Clearance to alcove ceiling
Maximum alcove depth
In addition to these clearances, adequate accessibility clearance for servicing and proper operation must be maintained.
Do not in any way obstruct the combustion air inlets that are located under the heater.
If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending at least the full width and depth of the appliance.
Venting
Use Only Approved Venting
The Clarity gas heater is tested and listed for connection to a 4" (100 mm) listed Class B venting system.
If the unit is installed to vent through an approved masonry chimney or a factory-built chimney system, an approved Class B chimney liner must be used.
Observe local codes when venting the Clarity. If no local codes exist, follow the current edition of ANSI Z223.1 and CAN1B149 installation codes.
Do not connect the venting to the flue of a chimney that serves a separate solid-fuel burning appliance.
The venting manufacturer's installation instructions must be followed exactly.
IMPORTANT: Because of the high efficiency and low flue gas temperatures of this appliance, it is important that it beconnected to a well-sealed and efficientventing system which is capable of registering a negative pressure while the stove is in operation.
The most efficient venting systems are those that have a minimum number of bends and minimal horizontal runs.
The Clarity gas heater is equipped with a thermally activated vent safety switch that will shut down the main burner if the heater is not properly venting. The safety switch will automatically reset after the heater has cooled down.
The switch will continue to cycle off and on until the venting problem is corrected. If you are unable to correct the venting problem, seek expert advice from your Harman dealer or installer.
DO NOT DISCONNECT OR BYPASS THE VENT SAFETY SWITCH.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safey shutoff system can result in carbon monoxide (CO) poisoning and possible death.
The Clarity gas heater is equipped with its own internal draft hood so no additional external draft hood is required. The heater should be installed so that the draft hood is in the same atmospheric pressure zone as the air inlets to the heater.
Test for Flue Spillage
A spillage test should always be made at the completion of the installation.
1.Start all exhaust fans in the home and then close all doors and windows in the room containing the heater.
2.Light the heater and allow it to run for 5 minutes on the high output setting. If the convection air blower is installed, it should be turned off for the test.
3.Hold a match or other source of smoke near the draft hood outlet on the upper back of the stove.
4.If the smoke is not drawn in, turn off the heater and determine the cause of the lack of draft. If necessary, seek expert advice.
For sites with swirling or turbulent wind conditions, a wind cap may solve the problem.
ASSEMBLY
The Clarity is shipped from the factory with the log set packed inside the firebox. To prepare the stove for installation, the log set must be unpacked, the appropriate burner system module for either natural gas or propane installed, and the logs installed.
Removing the Glass Front
NOTE: The glass front is heavy. Be prepared for its weight when lifting it to avoid damage during removal.
The wing doors on each side are held closed by magnets. Push on each door to open it. Loosen the wing nut on each of the two levers. Grasp each lever and push to the rear to disengage the front. To keep the levers in the disengaged position, tighten the wing nuts. Lift the glass front slightly and remove it from the stove. Set the glass aside in a safe place where it will not be damaged.
WARNING: Do not abuse the Clarity's glass by striking, slamming, or similar trauma. Do not operate the Clarity Vented Gas Heater with the glass panel removed,
1
2
3 4
The log set components are shipped from the factory individually wrapped and packed inside the stove. Take them out of the stove, then carefully remove the wrapping. Handle the logs gently as they may be damaged easily.
The front is released when levers on the left and right sides are pushed to the rear
cracked or broken. Use only glass supplied by Harman and approved for use with this heater. Do not use substitute materials. Replacement of the panel should be done by a licensed or qualified service person.
Remove and Unwrap the Log Set
As shown in the photo above right, the log set consists of a back log (1), a center log that has a pilot-viewing port in the left end (2), ember strip (3), and a branch that rests on top (4).
In addition, there are two side brick panels and a back brick panel.