Haier HPU-24C03/E1, HPU-18H03/E1, HPU-18C03/E1, HPU-24H03/E1 Manual

0 (0)

PACKAGED UNIT

OPERATION MANUAL

HPU-18C03/E1

HPU-24C03/E1

HPU-18H03/E1

HPU-24H03/E1

Please read this operation manual before using the air conditioner.

0010519818

Cautions

Disposal of the old air conditioner

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Safety Instructions and Warnings

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items , crushing or twisting any tubes , or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes , it may result in serious eye injuries.

1

Cautions

Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

Indoor

Maximum: D.B/W.B 32°C / 23°C

 

 

Minimum: D.B/W.B 18°C / 14°C

Cooling

 

 

 

 

Outdoor

Maximum: D.B/W.B 43°C / 26°C

 

 

 

 

Minimum: D.B

18°C

 

 

Indoor

Maximum: D.B

27°C

Heating

Minimum: D.B

15°C

 

 

Outdoor

Maximum: D.B/W.B 24°C / 18°C

 

 

Minimum: D.B/W.B -7°C/-8°C

 

 

 

 

 

2.If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken,please change it with the type of T. 3.15A/ 250V.

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the applience.

9.A breaker should be used in the circuits, which should be all-pole cutoff and the distance between its two contacts should be not at least 3mm .

10.Please employ the proper power plug, which fit into the power supply cord.

11.The power plug must have acquired the local attestation.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

Installation in an inadequate place may cause accidents. Do not install in the following place.

CAUTION

Connect the earth

Do not install in the

cable.

place where there

 

is any possibility

 

of inflammable

 

gas leakage around

 

the unit.

 

PROHIBITION

Use fuse with specified capacity. Replacement with steel or copper wires are absolutely prohibited.

FUSE

COPPERWIRE

STEEL WIRE

Do not get the unit exposed to vapor or oil steam.

PROHIBITION

Check proper installation of the drainage securely

STRICT

ENFORCEMENT

Grounding wire should not be connected to that of gas pipeline, water pipeline,lighting arrester or telephone.

3

Haier HPU-24C03/E1, HPU-18H03/E1, HPU-18C03/E1, HPU-24H03/E1 Manual

Cautions

Use of Air Conditioner

WARNING

When abnormality such as burnt-small found, immediately Use an exclusive power source with a circuit breaker.

stop the operation button and contact sales shop.

OFF

STRICT

 

 

ENFORCEMENT

Connect power supply cord to the

After installed, the unit shall be

Do not use power supply cord

outlet completely.

tested for electric leakage.

extended or connected in halfway.

STRICT

 

PROHIBITION

 

 

ENFORCEMENT

 

 

Do not use power supply cord in

Take care not to damage the

Do not insert objects into the air

a bundle.

power supply cord.

inlet or outlet.

 

 

PROHIBITION

PROHIBITION

PROHIBITION

 

Do not start or stop the operation

Do not channel the air flow directly

Do not try to repair or reconstruct

by disconnecting the power supply

at people, especially at infants or

by yourself.

cord and so on.

the aged.

 

PROHIBITION

PROHIBITION

 

 

CAUTION

 

Do not use for the purpose of

Take fresh air occasionally

Do not operate the switch with wet

storage of food, art work, precise

especially when gas appliance is

hand.

equipment, breeding , or cultivation.

running at the same time.

 

PROHIBITION

STRICT

 

ENFORCEMENT

PROHIBITION

Do not install the unit near a fireplace

Check good condition of the

Do not pour water onto the unit

or other heating apparatus.

installation stand.

for cleaning.

PROHIBITION

PROHIBITION

PROHIBITION

Do not place animals or plants in

Do not place any objects on or

Do not place flower vase or water

the direct path of the air flow.

climb on the unit.

containers on the top of the unit.

PROHIBITION

PROHIBITION

PROHIBITION

4

Parts and Functions

Indoor unit

 

 

1.OUTLET

2.CONTROL PANEL

3.INLET GRILLE

4.INLET

Outdoor unit

HPU-18C03/E1

HPU-24C03/E1

HPU-18H03/E1

HPU-24H03/E1

1.OUTLET

3.CONNECTING PIPING AND ELECTRICAL WIRING

2.INLET

4.DRAIN HOSE

5

Parts and Functions

17

20

14

15

B A

19

E.HEAT

28

1. RESET

When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.

2. LIGHT button

Control the lightening and extinguishing of the indoor LED display board.

3. TIMER button

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.

4.CLOCK button

Used to set correct time.

5.HEALTH button

Used to set healthy operation.

6.MODE button

AUTO COOL DRY HEAT FAN

7.HOUR button

Used to set clock and timer setting.

8.SWING UP/DOWN button

Used to select up or down air sending direction.

9.ON/OFF button

Used for unit start and stop.

28

10.TIMER ON display

11.FAN SPEED display

Remote controller

LOW MED

HI

AUTO

Control panel: See p17

12.LOCK display

13.SWING UP/DOWN display

14.SLEEP display

15.HEALTH display

16.E.HEATdisplay

17.Operation mode display

Operation mode AUTO COOL DRY HEAT FAN

Remote controller

Display board

18.Singal sending display

19.Left/right air flow display

20.TEMP display

Remote controller: to display the TEMP. setting.

21.TIMER OFF display

22.TIMER display

23.TEMP button

Used to select your desired temperature.

24.FAN button

Used to select fan speed: LOW,MED, HI, AUTO.

25.SLEE. P button

Used to select sleep mode.

26.SET button

Used to confirm timer and clock settings.

27.E.HEAT button

Used to operate electricity heat function. 28. LOCK Used to lock buttons and LED display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.

NOTE:(1) The following functions and related displays are not available: 5

(2) Cooling only unit do not have functions and displays related withheating.

(3)The air conditioner you bought, may not include the E.Heat function, is subject to the actual product.

6

Parts and Functions

16

19

14

15

B A

19

1. RESET

When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.

2. LIGHT button

Control the lightening and extinguishing of the indoor LED display board.

3. TIMER button

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.

4.CLOCK button

Used to set correct time.

5.HEALTH button

Used to set healthy operation.

6.MODE button

AUTO COOL DRY FAN

26

9.ON/OFF button

Used for unit start and stop.

10.TIMER ON display

11.FAN SPEED display

Remote controller

 

 

 

 

 

 

 

 

 

LOW MED

 

HI

 

AUTO

 

 

 

 

 

 

 

 

 

Control panel: See p17

12.LOCK display

13.SWING UP/DOWN display

14.SLEEP display

15.HEALTH display

16.Operation mode display

Operation mode AUTO COOL DRY FAN

Remote controller

Display board

17.Singal sending display

18.Left/right air flow display

19.TEMP display

Remote controller: to display the TEMP. setting.

20.TIMER OFF display

21.TIMER display

22.TEMP button

Used to select your desired temperature.

23.FAN button

Used to select fan speed: LOW,MED, HI, AUTO.

24.SLEE. P button

Used to select sleep mode.

25.SET button

Used to confirm timer and clock settings.

26.LOCK

Used to lock buttons and LED display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.

7.HOUR button

Used to set clock and timer setting.

8.SWING UP/DOWN button

Used to select up or down air sending direction.

NOTE:(1) The following functions and related displays are not available: 5

(2) Cooling only unit do not have functions and displays related with heating.

7

Parts and Functions

Clock Set

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

1.Press CLOCK button,"AM" or "PM" flashes.

2.Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.

3.After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.

E.HEAT

Remote controller's operation

When in use, put the signal transmission head directly to the receiver hole on the indoor unit.

The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.

Don't throw or knock the remoter controller.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.

Loading of the battery

Load the batteries as illustrated right 2 R-03 (7#) batteries

Remove the battery cover:

Slightly press" "area and push down the cover as illustrated.

Load the battery:

Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case.

Put on the cover again.

Confirmation indicator:

After pressing power ON/OFF, if no display, reload the batteries.

Note:

Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.

Used two new same-typed batteries when loading.

If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.

Hint:

Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.

8