Haier HPU-18CU13, HPU-20CU13 Manual

0 (0)

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HPU-18CU13

HPU-20CU13

Please read this operation manual before using the air conditioner

No.0010562446

Cautions

Disposal of the old air conditioner

Safety Instructions and Warnings

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require speciali-zed waste disposal. The valuable materials contained in an air conditioner can be recycled

Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts

out and gets into eyes, it may result in serious eye injuries.

1

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum:D.B/W.B

32oC/23oC

 

Minimum:D.B/W.B

18oC/14oC

Cooling

 

 

 

Outdoor

Maximum:D.B/W.B

43oC/26oC

 

Minimum:D.B

18oC

 

 

 

 

2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of

T.3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the applience.

9.Please employ the proper power plug, which fit into the power supply cord.

10 .The power plug and connecting cable must have acquired the local attestation.

11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.

12.When the cabinet A/C is normally working, if opening the glass door, the machine will stop working and the panel shows code "Fc". After closing the door, the code "Fc" disappears, and the machine will stop working and then restart automatically, and renew the original state.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

lnstallation in a inadequate place may cause accidents. Do not install in the following place.

CAUTION

Connect the earth cable.

earthing

Do not install in the place where there is any possibility of inflammable gas leakage around the unit.

PROHIBITION

Do not get the unit exposed to vapor or oil steam.

PROHIBITION

Check proper installation of the drainage securely

STRICT ENFORCEMENT

3

Haier HPU-18CU13, HPU-20CU13 Manual

Cautions

WARNING

When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.

OFF

STRICT

 

ENFORCEMENT

Use an exclusive power source with a circuit breaker

Connect power supply cord

Use the proper voltage

Do not use power supply cord

to the outlet completely

 

extended or connected in halfway

 

 

STRICT

STRICT

PROHIBITION

ENFORCEMENT

ENFORCEMENT

 

Do not use power supply cord

Take care not to damage

Do not insert objects into the air

in a bundle.

the power supply cord.

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

Do not channel the air flow directly

Do not try to repair or reconstruct

operation by disconnecting

at people, especially at infants or

by yourself.

the power supply cord and so on.

the aged.

 

PROHIBITION

PROHIBITION

 

 

CAUTION

 

Do not use for the purpose of storage of

Take fresh air occasionally especially

Do not operate the switch with

food, art work, precise equipment,

when gas appliance is running at the

wet hand.

breeding, or cultivation.

same time.

 

 

STRICT

PROHIBITION

PROHIBITION

ENFORCEMENT

Do not install the unit near a fireplace

Check good condition of the

Do not pour water onto the unit

or other heating apparatus.

installation stand

for cleaning

 

 

PROHIBITION

PROHIBITION

PROHIBITION

Do not place animals or plants in

Do not place any objects on or

Do not place flower vase or water

the direct path of the air flow

climb on the unit.

containers on the top of the unit.

 

PROHIBITION

PROHIBITION

PROHIBITION

4

Parts and Functions

Indoor unit

7

 

1

Outlet

 

2

Control panel

 

3

Inlet grille

 

4

Air filter(inside)

3

5

UV light degerming device (inside)

6

Inlet

 

4

7

Anion generator (inside)

5

 

 

6

 

 

5

Parts and Functions

Display board

1.Operation mode display

2.Room temperature display, Setting temperature display

3.HEALTH display

4.TIMER ON / OFF display

5.SLEEP display

6.POWER / SOFT display

7.ON/OFF button

Used for unit start and stop.

8.MODE button

AUTO COOL DRY FAN

9.AIR FLOW button

10.TEMP button

Used to select your desired temperature.

 

SET

HEALTH

3

 

 

 

HUMI

TIMER

4

2

TEMP.

SLEEP

5

 

 

 

1

 

 

 

6

8

7

ON/OFF

AIR FLOW

9

10

TEMP +

TEMP -

Outdoor unit

HPU-18CU13

 

HPU-20CU13

1

OUTLET

3

CONNECTING PIPING AND ELECTRICAL WIRING

2

INLET

4

DRAIN HOSE

6

Parts and Functions

19

28

1.RESET

When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.

2.LIGHT button

Control the lightening and extinguishing of the indoor LED display board.

3. TIMER button

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.

4. CLOCK button

Used to set correct time.

5. SLEEP button

Used to select sleep mode.

6. MODE button

AUTO COOL DRY FAN

7.HOUR button

Used to set clock and timer setting.

8.HEALTH button

Used to set healthy operation.

9.ON/OFF button

Used for unit start and stop.

10. TIMER ON display

11. FAN SPEED display

LOW

MED

HI

AUTO

12.LOCK display

13.SWING UP/DOWN display

14.SLEEP display

15.HEALTH display

16.Operation mode display

Operation mode AUTO COOL DRY FAN

Remote controller

Display board

17.Singal sending display

18.POWER/SOFT display

19.Left/right air flow display

20.TEMP display

Remote controller: to display the TEMP. setting.

21.TIMER OFF display

22.CLOCK display

23.TEMP button

Used to select your desired temperature.

24.FAN button

Used to select fan speed: LOW,MED, HI, AUTO.

25.SWING UP/DOWN button

Used to select up or down air sending direction.

26.SWING LEFT/RIGHT button

Used to select left/right air flow.

27.SET button

Used to confirm timer and clock settings.

28.LOCK

Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.

NOTE: 1.Cooling only unit do not have functions and displays related with heating.

7

Loading...
+ 17 hidden pages