GE Healthcare OEC Brivo Plus Brochure

5 (2)
GE Healthcare OEC Brivo Plus Brochure

GE Healthcare

OEC Brivo Plus

Digital Mobile C-arm

Technical Data

Adding more to your surgical imaging capabilities.

Advanced hardware, optimized image processing and dose management software provide superb image quality at a lower dose. The clinically versatile OEC Brivo Plus promises features to help add to your mobile surgical imaging capabilities.

1k x 1k high resolution imaging technology from a fully digital image processing system

9” Image Intensifier provides high spatial resolution

Brilliant radiation safety features ensure you get the right image at the right dose

Carbon fiber grid reduces scatter radiation effect while improving image detail

Available Pediatric package for clear images with lower dose when imaging children

Intuitive user interface with touch screen can reduce procedure time and improve efficiency

Advanced connectivity including wireless DICOM, MPPS and DVI options

Data protection and compliance including a UPS to protect patient data

GE imagination at work

X-ray System

Generator

40kHz high frequency

2.2kW monoblock

Housing heat capacity: 900,000HU

Housing cooling rate: 12,500HU/min

Up to 110kVp

Up to 20mA for radiographic film exposure

Continuous high level fluoro (HLF) up to 12mA

Digital spot up to 16mA

X-ray Tube

Stationary anode X-ray tube

Dual focal spot:

-Small focal spot: 0.6mm x 1.4mm

-Large focal spot: 1.4mm x 1.4mm

Tube assembly total filtration 3.35mm Al

Anode heat capacity: 76,000HU

Maximum anode cooling rate: 37,000HU/ min

On-screen tube heat capacity indicator

PreView Collimator

On-screen collimator position indication

PreView iris collimator

PreView tungsten rotatable double leaf collimator

Adjusts collimators without X-ray exposure

Normal Fluoro Mode

kVp range: 40 -110

mA range: 0.1 - 4

Auto and manual fluoro modes

Low Dose Fluoro Mode

kVp range: 40 -110

mA range: 0.1 - 2

Auto and manual fluoro modes

High Level Fluoro Mode

kVp range: 40 -110

mA range: up to 12

Auto and manual fluoro modes

Pulsed Fluoro Mode

kVp range: 40 -110

mA range: 0.1 - 4

Pulse rate: 1, 2, 4, 8 PPS

Auto and manual fluoro modes

Can reduce X-ray dose to patient and operator

Low Dose Pulsed Fluoro

kVp range: 40 -110

mA range: 0.1 - 2

Pulse rate: 1, 2, 4, 8 PPS

Auto and manual fluoro modes

High Level Pulsed Fluoro

kVp range: 40 -110

mA range: up to 12

Pulse rate: 1, 2, 4, 8 PPS

Auto and manual fluoro modes

Digital Spot Mode

kVp range: 40 - 110

Up to 10mA for 100-120V system

Automatic exposure termination and automatic image save

Radiographic Mode

mA range: 20 (10 for 100-120V system)

mAs range: up to 80 (40 for 100-120V system)

Computer controlled exposure time

Film cassette holder: 10” x 12” (25.4cm x 30.5cm)

Video Imaging System

Precise-Imaging features

AutoTrak

-Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique

-Automatically adjusts to anatomical size and location

-Provides uniform image quality throughout entire image

-Simplifies operation

Smart Window

-Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality

Smart Metal

-Automatically detects the metal in field and optimizes image quality

-Allows user to adjust automatic brightness and contrast sensitivity levels to metal

-Provides optimum image quality even when metal is introduced to the field

9” Image Intensifier

Tri-mode 9”/6”/4.5” (23cm/15cm/11cm) image intensifier, The central resolution (typical value at image intensifier):

-9” (23cm): 52 lp/cm

-6” (15cm): 58 lp/cm

-4.5” (11cm): 68 lp/cm

Minimum central resolution (at monitor):

-9” (23cm): 2.2 lp/mm

-6” (15cm): 3.0 lp/mm

-4.5” (11cm): 3.5 lp/mm

DQE: 65% (typical)

Tungsten Collimator

Denser collimator limits X-ray exposure area

Reduces scatter radiation

Improves image detail

Carbon Fiber Grid

60L/cm 10:1 anti-scatter grid

Reduces scatter radiation effect

Improves image detail

Video Camera

High resolution 1k x 1k CCD camera

Full digital interface

Variable gain control

Video Display

Dual medical 19” (48cm) monochrome LCD with anti-glare panel.

-Tilt motion: 7 degree up / 10 degree down

-Swivel motion: 180 degree

-Viewing angle: 170 degree horizontal and vertical

Maximum brightness: 1000 Cd/m2

Maximum contrast: 900:1

1280 x 1024 high resolution

Digital Visual Input (DVI) interface for external monitors

Image Processing

Image Processing

1k x 1k x 16 bit image processing

Dynamic recursive filter with adaptation to motion

-Allows user to adjust noise filter levels to produce high image quality

-Provides optimum image quality even when motion is introduced to the field

Automatic digital brightness and contrast control

Manual digital brightness and contrast control

Auto adaptive non-uniformity correction

Image edge enhancement

Image negate mode

Image save and auto-save

Image swap and auto-swap

Last image hold (LIH)

Image zoom and roam

Left-right image reversal

Top-bottom image invert

Digital Image Rotation

-360 degree real-time rotation for live and static images

-Image positioning without additional exposure

HIPAA SecureView

-Password protection

-Blank screen function

-Delete all

Measurement Software

-Distance measurement

-Angle measurement

-Multi-unit support (French, mm, Inch)

-User calibration

Image Annotation

-Arrows and markers

-Comments

-Cropping

100,000 images storage

Exam Management

Patient information

-Examination list

-Customized patient information

Loading...
+ 2 hidden pages