Franke Foodservice HCMF-18 18005560 Service Manual

0 (0)

HCMF Service Manual

High Capacity Meat Freezers

 

 

 

 

 

 

 

 

 

 

Model HCMF-18 (18” wide)

Model HCMF-30 (30” wide)

 

 

Section Contents

Section

Page

HCMF Model Overview & Specifications

1

2

Control Settings & Operating Parameters

2

4

Electric & Compressor Schematics

3

5

Trouble Shooting Table

4

7

Eliwell Controller Error Codes

5

9

Component Parts List & Diagrams

6

11

Basic Operator Preventive Maintenance

7

13

General Unit Service Instructions & Warnings

8

14

Key Parts Replacement Tips

9

15

Component Adjustments

10

19

For Technical Support, Call 800-537-2653.

Page 1

Doc. No. 19005309 - Copyright 2012 Franke, Inc.

HCMF Service Manual

Section 1 – Model Overview & Specifications:

Model HCMF Series – High Capacity Meat Freezers

The HCMF is a compact, custom freezer designed for short-term grill-side storage of frozen hamburger patties and secondary grilled product, providing quick and easy access at point-of-use. Designed to be positioned immediately adjacent to the Grill Station, the HCMF is available in two sizes, 18-inches wide and 30-inches wide, with a front case-loading door and an insulated, automatic roll-back top lid that provides quick access, with minimum exposure of frozen product.

Unlike previous grill-side freezers (GSF & FRGSF), HCMF Models have a top mounted condenser package that provides easy access for regular PM and service access from five sides. HCMF Models are more energy efficient, provide more storage space, cost less to operate and have the following specifications and utility requirements:

 

Key Performance Specifications

 

 

 

 

 

 

 

 

Product Model:

HCMF-18

 

HCMF-30

 

 

Part Number:

18005560

 

18005519*

 

 

Capacity: Cubic Feet

6.8

 

13.1

 

 

Capacity: Burgers

3 box

 

6 boxes

 

 

Refrigeration/Type:

Forced air cooling system

using R-404A Refrigerant

 

 

Agency Listings:

CULUS & NSF

 

CULUS & NSF

 

 

Key Dimensions & Weights

 

 

 

 

 

Unit Width:

18” (458 mm)

 

30.86” (784 mm)

 

 

Unit Depth [front-to-back]:

37” (940 mm)

 

37” (940 mm)

 

 

Unit Height

54.77” (1391 mm)

 

54.77” (1391 mm)

 

 

Minimum Door Swing

+22” (to depth)

 

+32” (to depth)

 

 

Shipping Weight

337 lbs.

 

427 lbs.

 

 

Unit Operating Weight

265 lbs.

 

365 lbs.

 

 

Electrical/Utility Requirements

 

 

 

 

Voltage [VAC]

120 VAC

 

120 VAC

 

 

Phase [PH]

1-phase

 

1-phase

 

 

Cycles [Hz]

60 Hz

 

60 Hz

 

 

Amperage [AMP]

7.3 AMPs

 

10 AMPs

 

 

Watts

840

 

1200

 

 

Power Cord Provided

Yes

 

Yes

 

 

Plug Provided

Straight Blade

 

Straight Blade

 

 

Installation/Operating

Conditions/Requirements

 

 

 

 

Max. Room Temp.

82 F

 

82 F

 

 

Max. Room Humidity

60%

 

60%

 

 

Min. Side Clearance

0” (2” recommended)

0” (2” recommended)

 

 

Min. Rear Clearance

1” (2” recommended)

1” (2” recommended)

 

* NOTE: P/N: 18005519 has the condenser mounted top-right. P/N 18005056 has the

 

condenser factory-mounted top-left.

 

 

 

 

 

 

 

 

 

For Technical Support, Call 800-537-2653.

Page 2

Doc. No. 19005309 - Copyright 2012 Franke, Inc.

HCMF Service Manual

Model HCMF Key Components

HCMF-30 [18005519 – Condenser-Right] Model Shown

Front Vented

Condenser Coil

Access Panel

Top Roll-Back

Product Access

Door

Disposable Glove

Bracket Mounting

Location

Front Door

(Shown Hinged

Right – Field

Reversible)

Temperature

Display/Controller

Locking Front

Casters

Grill Tool Shelf

Right Side

Service Access

Panel

Power ON/OFF

Switch

(Rear-View)

For Technical Support, Call 800-537-2653.

Page 3

Doc. No. 19005309 - Copyright 2012 Franke, Inc.

HCMF Service Manual

Section 2 – Control Settings & Operating Parameters:

Control Settings & Operating Characteristics (For Troubleshooting)

 

Danfoss Temperature Controller

 

 

 

For More Information

 

 

 

Temperature Range

 

Adjustable

 

 

 

 

 

 

 

Coldest Set Point

-30 degrees F

 

See Section 10 on page 19 to adjust

 

 

 

Normal Cut Out (Set Point)

- 4 degrees F

 

 

 

 

Differential

2 degrees F

 

temperature

 

 

 

 

 

Normal Cut In

- 2 degrees F

 

 

 

 

 

 

 

Warmest Set Point

+30 degrees F

 

 

 

 

 

 

 

Compressor Protection

 

Fixed

 

 

 

 

 

 

 

Minimum On Time from Start to Start

2 minutes

 

 

 

 

 

 

 

Fail Safe Mode (if sensor fails)

 

Fixed

 

 

 

 

 

 

 

Faulty Probe On Time

4 minutes

 

 

 

 

 

 

 

Error Off Time

2 minutes

 

 

 

 

 

 

 

Defrost Settings

 

Fixed

 

 

 

 

 

 

 

Termination Temperature

60 degrees F

 

 

 

 

 

 

 

Maximum Time Allowed

60 minutes

 

 

 

 

 

 

 

Drip Time (heat off)

1 minute

 

 

 

 

 

 

 

Defrost Based On Compressor On Time

 

Fixed

 

 

 

 

 

 

 

Time Between Defrosts

3 hours

 

 

 

 

 

 

 

Fan Settings

 

Fixed

 

 

 

 

 

 

 

During Defrost

Off

 

 

 

 

 

 

 

Start Delay After Defrost

4 minutes

 

 

 

 

 

 

 

Fan Duty Cycle – ON

40 seconds

 

 

 

 

 

 

 

Fan Duty Cycle - OFF

90 seconds

 

 

 

 

 

 

 

Display Features:

 

Adjustments

 

 

 

 

 

 

 

Select degrees F or C?

 

No

 

NOTE: Contact Franke for degrees C

 

 

Adjust temperature from display?

 

Yes

 

See Section 10 on page 19 to adjust

 

 

 

Initiate Defrost from display?

 

Yes

 

temperature or initiate manual defrost

 

 

 

 

 

dEF

 

NOTE: dEF shown for maximum of 30

 

 

Display during Defrost Cycle:

 

 

minutes after defrost.

 

 

 

 

 

 

 

 

 

 

 

Normal Operating Pressures

 

 

 

Normal Operating Amps

 

 

 

High Side (85 air to condenser)

 

235 PSIG

 

HCMF-30

8 – 9 Amps

(4.8A Defrost)

 

 

Low Side (-5 air into coil)

 

13 PSIG

 

HCMF-18

5 – 6 Amps

(3.8 Defrost)

 

 

 

 

 

 

 

 

 

High Pressure Safety

 

 

 

Rated Operating Amps

 

 

 

Cut Out Setting

 

460 PSIG

 

HCMF-30

10 Amps

 

 

 

 

Differential

 

30 PSIG

 

HCMF-18

7.3 Amps

 

 

 

 

 

 

 

 

 

 

 

Defrost High Limit Safety

 

 

 

Operating Voltage

 

 

 

Cut Out Setting

 

70 degrees F

 

HCMF-30

120V

 

 

 

 

Differential

 

15 degrees F

 

HCMF-18

120V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigeration Type & Quantity:

 

HCMF-30

 

HCMF-18

 

 

 

 

 

R-404A

 

18 ounces

 

16 ounces

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Technical Support, Call 800-537-2653.

 

Page 4

 

Doc. No. 19005309 - Copyright 2012 Franke, Inc.

Franke Foodservice HCMF-18 18005560 Service Manual

HCMF Service Manual

Section 3 – Electric & Compressor Schematics:

HCMF-18 & HCMF-30 Wiring Harness

NOTE:

Model HCMF-18 has one fan motor

Model HCMF-30 has two fan motors

For Technical Support, Call 800-537-2653.

Page 5

Doc. No. 19005309 - Copyright 2012 Franke, Inc.

HCMF Service Manual

Copeland Compressor Schematic

Model HCMF-18 – Copeland No. M4FL-H038-IAA-121 – Franke P/N: 19004507 Model HCMF-30 – Copeland No. M4FL-H047-IAA-121 – Franke P/N: 19004310

For Technical Support, Call 800-537-2653.

Page 6

Doc. No. 19005309 - Copyright 2012 Franke, Inc.

Loading...