HCMF Service Manual
High Capacity Meat Freezers
|
|
|
|
|
|
|
|
|
|
Model HCMF-18 (18” wide) |
Model HCMF-30 (30” wide) |
|
||
|
Section Contents |
Section |
Page |
HCMF Model Overview & Specifications |
1 |
2 |
Control Settings & Operating Parameters |
2 |
4 |
Electric & Compressor Schematics |
3 |
5 |
Trouble Shooting Table |
4 |
7 |
Eliwell Controller Error Codes |
5 |
9 |
Component Parts List & Diagrams |
6 |
11 |
Basic Operator Preventive Maintenance |
7 |
13 |
General Unit Service Instructions & Warnings |
8 |
14 |
Key Parts Replacement Tips |
9 |
15 |
Component Adjustments |
10 |
19 |
For Technical Support, Call 800-537-2653. |
Page 1 |
Doc. No. 19005309 - Copyright 2012 Franke, Inc. |
HCMF Service Manual
Section 1 – Model Overview & Specifications:
Model HCMF Series – High Capacity Meat Freezers
The HCMF is a compact, custom freezer designed for short-term grill-side storage of frozen hamburger patties and secondary grilled product, providing quick and easy access at point-of-use. Designed to be positioned immediately adjacent to the Grill Station, the HCMF is available in two sizes, 18-inches wide and 30-inches wide, with a front case-loading door and an insulated, automatic roll-back top lid that provides quick access, with minimum exposure of frozen product.
Unlike previous grill-side freezers (GSF & FRGSF), HCMF Models have a top mounted condenser package that provides easy access for regular PM and service access from five sides. HCMF Models are more energy efficient, provide more storage space, cost less to operate and have the following specifications and utility requirements:
|
Key Performance Specifications |
|
|
|
|
|
|
|
|
||
|
Product Model: |
HCMF-18 |
|
HCMF-30 |
|
|
Part Number: |
18005560 |
|
18005519* |
|
|
Capacity: Cubic Feet |
6.8 |
|
13.1 |
|
|
Capacity: Burgers |
3 box |
|
6 boxes |
|
|
Refrigeration/Type: |
Forced air cooling system |
using R-404A Refrigerant |
|
|
|
Agency Listings: |
CULUS & NSF |
|
CULUS & NSF |
|
|
Key Dimensions & Weights |
|
|
|
|
|
Unit Width: |
18” (458 mm) |
|
30.86” (784 mm) |
|
|
Unit Depth [front-to-back]: |
37” (940 mm) |
|
37” (940 mm) |
|
|
Unit Height |
54.77” (1391 mm) |
|
54.77” (1391 mm) |
|
|
Minimum Door Swing |
+22” (to depth) |
|
+32” (to depth) |
|
|
Shipping Weight |
337 lbs. |
|
427 lbs. |
|
|
Unit Operating Weight |
265 lbs. |
|
365 lbs. |
|
|
Electrical/Utility Requirements |
|
|
|
|
|
Voltage [VAC] |
120 VAC |
|
120 VAC |
|
|
Phase [PH] |
1-phase |
|
1-phase |
|
|
Cycles [Hz] |
60 Hz |
|
60 Hz |
|
|
Amperage [AMP] |
7.3 AMPs |
|
10 AMPs |
|
|
Watts |
840 |
|
1200 |
|
|
Power Cord Provided |
Yes |
|
Yes |
|
|
Plug Provided |
Straight Blade |
|
Straight Blade |
|
|
Installation/Operating |
Conditions/Requirements |
|
|
|
|
Max. Room Temp. |
82 F |
|
82 F |
|
|
Max. Room Humidity |
60% |
|
60% |
|
|
Min. Side Clearance |
0” (2” recommended) |
0” (2” recommended) |
|
|
|
Min. Rear Clearance |
1” (2” recommended) |
1” (2” recommended) |
|
|
* NOTE: P/N: 18005519 has the condenser mounted top-right. P/N 18005056 has the |
|||||
|
condenser factory-mounted top-left. |
|
|
|
|
|
|
|
|
|
|
For Technical Support, Call 800-537-2653. |
Page 2 |
Doc. No. 19005309 - Copyright 2012 Franke, Inc. |
HCMF Service Manual
Model HCMF Key Components
HCMF-30 [18005519 – Condenser-Right] Model Shown
Front Vented
Condenser Coil
Access Panel
Top Roll-Back
Product Access
Door
Disposable Glove
Bracket Mounting
Location
Front Door
(Shown Hinged
Right – Field
Reversible)
Temperature
Display/Controller
Locking Front
Casters
Grill Tool Shelf
Right Side
Service Access
Panel
Power ON/OFF
Switch
(Rear-View)
For Technical Support, Call 800-537-2653. |
Page 3 |
Doc. No. 19005309 - Copyright 2012 Franke, Inc. |
HCMF Service Manual
Section 2 – Control Settings & Operating Parameters:
Control Settings & Operating Characteristics (For Troubleshooting)
|
Danfoss Temperature Controller |
|
|
|
For More Information |
|
|
||
|
Temperature Range |
|
Adjustable |
|
|
|
|
|
|
|
Coldest Set Point |
-30 degrees F |
|
See Section 10 on page 19 to adjust |
|
|
|||
|
Normal Cut Out (Set Point) |
- 4 degrees F |
|
|
|
||||
|
Differential |
2 degrees F |
|
temperature |
|
|
|
|
|
|
Normal Cut In |
- 2 degrees F |
|
|
|
|
|
|
|
|
Warmest Set Point |
+30 degrees F |
|
|
|
|
|
|
|
|
Compressor Protection |
|
Fixed |
|
|
|
|
|
|
|
Minimum On Time from Start to Start |
2 minutes |
|
|
|
|
|
|
|
|
Fail Safe Mode (if sensor fails) |
|
Fixed |
|
|
|
|
|
|
|
Faulty Probe On Time |
4 minutes |
|
|
|
|
|
|
|
|
Error Off Time |
2 minutes |
|
|
|
|
|
|
|
|
Defrost Settings |
|
Fixed |
|
|
|
|
|
|
|
Termination Temperature |
60 degrees F |
|
|
|
|
|
|
|
|
Maximum Time Allowed |
60 minutes |
|
|
|
|
|
|
|
|
Drip Time (heat off) |
1 minute |
|
|
|
|
|
|
|
|
Defrost Based On Compressor On Time |
|
Fixed |
|
|
|
|
|
|
|
Time Between Defrosts |
3 hours |
|
|
|
|
|
|
|
|
Fan Settings |
|
Fixed |
|
|
|
|
|
|
|
During Defrost |
Off |
|
|
|
|
|
|
|
|
Start Delay After Defrost |
4 minutes |
|
|
|
|
|
|
|
|
Fan Duty Cycle – ON |
40 seconds |
|
|
|
|
|
|
|
|
Fan Duty Cycle - OFF |
90 seconds |
|
|
|
|
|
|
|
|
Display Features: |
|
Adjustments |
|
|
|
|
|
|
|
Select degrees F or C? |
|
No |
|
NOTE: Contact Franke for degrees C |
|
|||
|
Adjust temperature from display? |
|
Yes |
|
See Section 10 on page 19 to adjust |
|
|
||
|
Initiate Defrost from display? |
|
Yes |
|
temperature or initiate manual defrost |
|
|
||
|
|
|
dEF |
|
NOTE: dEF shown for maximum of 30 |
|
|||
|
Display during Defrost Cycle: |
|
|
minutes after defrost. |
|
|
|
||
|
|
|
|
|
|
|
|||
|
Normal Operating Pressures |
|
|
|
Normal Operating Amps |
|
|
||
|
High Side (85 air to condenser) |
|
235 PSIG |
|
HCMF-30 |
8 – 9 Amps |
(4.8A Defrost) |
|
|
|
Low Side (-5 air into coil) |
|
13 PSIG |
|
HCMF-18 |
5 – 6 Amps |
(3.8 Defrost) |
|
|
|
|
|
|
|
|
|
|||
|
High Pressure Safety |
|
|
|
Rated Operating Amps |
|
|
||
|
Cut Out Setting |
|
460 PSIG |
|
HCMF-30 |
10 Amps |
|
|
|
|
Differential |
|
30 PSIG |
|
HCMF-18 |
7.3 Amps |
|
|
|
|
|
|
|
|
|
|
|||
|
Defrost High Limit Safety |
|
|
|
Operating Voltage |
|
|
||
|
Cut Out Setting |
|
70 degrees F |
|
HCMF-30 |
120V |
|
|
|
|
Differential |
|
15 degrees F |
|
HCMF-18 |
120V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Refrigeration Type & Quantity: |
|
HCMF-30 |
|
HCMF-18 |
|
|
|
|
|
R-404A |
|
18 ounces |
|
16 ounces |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For Technical Support, Call 800-537-2653. |
|
Page 4 |
|
Doc. No. 19005309 - Copyright 2012 Franke, Inc. |
HCMF Service Manual
Section 3 – Electric & Compressor Schematics:
HCMF-18 & HCMF-30 Wiring Harness
NOTE:
Model HCMF-18 has one fan motor
Model HCMF-30 has two fan motors
For Technical Support, Call 800-537-2653. |
Page 5 |
Doc. No. 19005309 - Copyright 2012 Franke, Inc. |
HCMF Service Manual
Copeland Compressor Schematic
Model HCMF-18 – Copeland No. M4FL-H038-IAA-121 – Franke P/N: 19004507 Model HCMF-30 – Copeland No. M4FL-H047-IAA-121 – Franke P/N: 19004310
For Technical Support, Call 800-537-2653. |
Page 6 |
Doc. No. 19005309 - Copyright 2012 Franke, Inc. |