INSTALLATION INSTRUCTIONS
IMPORTANT - PLEASE READ AND FOLLOW
• Before beginning, please read these instructions completely and carefully.
• Do not remove permanently affi xed labels, warnings, or plates from the product. This may
void the warranty.
• Please observe all local and national codes and ordinances.
• Please ensure that this product is properly grounded.
• The electrical plug should always be accessible.
• The installer should leave these instructions with the consumer who should retain
for local inspector’s use and for future reference.
Installation must conform with local codes or in the absence of codes, the National Fuel Gas
Code ANSI Z223.1/NFPA 54 - Iatest edition. Electrical installation must be in accordance with
the National Electrical Code, ANSI/NFPA70 - latest edition and/or local codes.
IN CANADA: Installation must be in accordance with the current CAN/CGA-B149.1 National
Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.
Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical
Codes Part 1 and/or local codes.
INSTALLATION IN MANUFACTURED (MOBILE) HOME: The installation must conform with
the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)]
or, when such standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1, or with local codes where applicable.
INSTALLATION IN RECREATIONAL PARK TRAILERS: The installation must conform with
state or other codes or, in the absence of such codes, with the Standard for Recreational
Park Trailers, ANSI A1 19.5.
Installation of any gas-fi red equipment should be made by a licensed plumber. A manual
shut-off valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance (In Massachusetts
such shutoff devices should be approved by the Board of State Examiners of Plumbers &
Gas Fitters).
If an external electrical source is utilized, the appliance, when installed, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the national
Electrical Code, ANSI/NFPA 70.
Some models are supplied with a protective fi lm on steel and aluminium
parts. This fi lm must be removed before installing/using the appliance.
FOR INSTALLER ONLY
THIS RANGE IS FOR RESIDENTIAL USE ONLY
590598A 1104407-ß1 07.13
2
WARNING !
T o reduce the risk of tipping the appliance,
the appliance must be secured by properly
installed anti-tip device packed with the
appliance.
• ALL RANGES CAN TIP
• INJURY TO PERSONS COULD RESULT
• INSTALL ANTI-TIP DEVICE PACKED
WITH RANGE
• SEE INSTALLATION INSTRUCTIONS
WARNING !
If the information in this manual is not followed exactly,
a fi re or explosion may result causing property damage,
personal injury, or death.
–Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
–NEVER use this appliance as a space heater to heat or warm
the room. Doing so may result in carbon monoxide poisoning and overheating of the appliance.
–WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• lmmediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• lf you cannot reach your gas supplier, call the fi re de-
partment.
–Installation and service must be performed by a qualifi ed
installer, service agency, or the gas supplier.
2
3
DATA PLATE
CONVERSION LABEL
The product data plate is
attached below the bottom
drawer. To check the label,
it is necessary to remove
the drawer (operating as
indicated in this manual).
The Governor of California is required to publish a list of substances known to the state of California to cause cancer or reproductive harm and requires businesses to warn customers of potential
exposures to such substances.
WARNING!: Gas appliances contain or produce substances which can cause death or serious
illness and which are known to the State of California to cause cancer, birth defects or other reproductive harm. To reduce the risk from substances in fuel or from fuel combustion, make sure this
appliance is installed, operated, and maintained according to the manufacturer’s instructions.
This appliance is designed and manufactured solely for the cooking of domestic (household) food
and in not suitable for any non-domestic application and therefore should not be used in a commercial environmement.
The appliance warranty will be void if the appliance is used within a non-domestic environment i.e.
a semi commercial, commercial or communal environment.
3
4
INSTALLATION INSTRUCTIONS
WARNING!
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.
Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a qualifi ed installer, service agent, or the gas supplier.
IMPORTANT: The use of suitable protective clothing/gloves is
recommended when handling or installing this appliance.
TOOLS NEEDED FOR INSTALLATION (NOT SUPPLIED WITH THE APPLIANCE)
Screwdriver2 - Wrench
Suitable protective
gloves
Hammer
T-handle
wrench
Adjustable
wrench
Adjustable
pliers
Tape
measurePencil
Drill
4
5
GENERAL INFORMATION
1. Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54
CGA-B149.2.
2. Installation in manufactured (mobile) home: installation must
conform with the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 [formerly the
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or with local codes where
applicable.
3. Installation in Recreational Park Trailers: installation must
conform with state or other codes or, in the absence of such
codes, with the Standard for Recreational Park Trailers,
ANSI A119.5.
4. To eliminate risk of burns or fi re by reaching over heated sur-
face units, cabinet storage located above the surface units
should be avoided.
5. Air curtain or other overhead range hoods, which operate by
blowing a downward air fl ow on to a range, shall not be used
in conjunction with gas ranges other than when the hood and
range have been designed, tested and listed by an independent test laboratory for use in combination.
- Latest Edition, CAN/CGA-B149.1 or CAN/
16. When installing or removing the range for service, a rolling lift
jack should be used. Do not push against any of the edges of
the range in an attempt to slide it into or out of the installation.
Pushing or pulling a range (rather than using a lift jack) also
increases the possibility of bending the leg spindles or the
internal coupling connectors.
WARNING!!
ELECTRICAL GROUNDING INSTRUCTIONS
The range must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70-latest edition, in Canada Canadian Electrical Code.
Installation should be made by a Iicensed electrician.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PRO-
PERLY GROUNDED.
If an external electrical source is utilized, the installation must be
electrically grounded in accordance with local codes or, in the
absence of local codes, with the national Electrical Code, ANSI/
NFPA 70.
6.
This appliance shall not be used for space heating. This
information is based on safety considerations.
7. AlI openings in the wall behind the appliance and in the fl oor
under the appliance shall be sealed.
8. Keep appliance area clear and free from combustible materials, gasoline, and other fl ammable vapors.
9. Do not obstruct the fl ow of combustion and ventilation air.
10. Disconnect the electrical supply to the appliance before servicing.
11. When removing appliance for cleaning and/or service;
A. Shut off gas at main supply.
B. Disconnect AC power supply.
C. Disconnect gas line to the inlet pipe.
D. Carefully remove the range by pulling outward.
CAUTION: Range is heavy; use care in handling.
Electrical Requirement
12.
Electrical installation should comply with national and local
codes.
13.
Air Supply and Ventilation
The installer must refers to local/national codes.
WARNING!!
This appliance is equipped with a four-prong grounding plug
(NEMA 14-50P) for your protection against shock hazard and
should be plugged directly into a properly grounded socket.
Do not under any circumstances cut or remove the fourth
(ground) prong from the power plug.
REPLACEMENT PARTS
Only authorized replacement parts may be used in performing service on the range. Replacement parts are available from factory
authorized parts distributors. Contact the nearest parts distributor
in your area.
14.
Gas Manifold Pressure
Natural gas - 4.0” W.C.P.
LP/Propane - 11.0” W.C.P.
15. The misuse of oven door (e.g. stepping, sitting, or leaning on
them) can result in potential hazards and/or injuries.
5
6
1
3”
(76 mm)
MIN 35” 21/32 (906 mm)
MAX 36” 11/32 (923 mm)
24” 3/16
(615 mm)
Fig. 1.1
29” 7/8
(759 mm)
installation
PROXIMITY TO SIDE CABINETS
1. This range may be installed directly adjacent to existing 36” (914 mm)
high base cabinets.
Range dimensions:
• width: 29” 7/8 (759 mm)
• depth: 24” 3/16 (615 mm)
• height (without backguard): MIN 35” 21/32 (906 mm) - MAX 36” 11/32
(923 mm)
• backguard (height): 3” (76 mm)
Gas line opening: Wall - 37/64” (14.5 mm) from the right side to centre
of range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depending on feet
regulation] from the fl oor.
Grounded outlet: should be located 37/64” (14.5 mm) from the left side
to centre of range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depending on feet regulation] from the fl oor.
The electric cord with 4-prong ground plug (NEMA 14-50P) shall have
a minimum length of 48” (1220 mm) beyond the back of the appliance.
2. The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (914 mm)
high.
There must be a minimum of 1 1” 13/16 (300 mm) side clearance from the
range to such combustible surfaces TO THE LEFT or TO THE RIGHT
above the 36” (914 mm) high countertop.
IMPORTANT: One side (left or right) above the 36” (914 mm) high
countertop must always be kept clear.
Island installation: There must be a minimum of 12” (305 mm) clearan-
ce from the rear of the backguard to such combustible surface on the
back of the range above the 36” (914 mm) high countertop.
3. The maximum upper cabinet depth recommended is 13” (330 mm). Wall
cabinet above the range must be a minimum of 30” (762 mm) above the
countertop for a width of minimum 30” (762 mm): it has to be centered
with the range. Side wall cabinets above the range must be a minimum
of 18” (457 mm) above the countertop.
6
7
Dotted line showing the position
of the range when installed
1
GAS AND ELECTRIC CONNECTION
Ref.inchmm
A5” 7/16 - 6” 1/8 (*)138 - 155.5 (*)
B14” 3/8365
C37/64”14.5
(*) : Depending on feet regulation
Area for
ELECTRICAL
connection
C
B
A
Area for
GAS connection
B
C
Fig. 1.2
ASSEMBLING THE BACKGUARD
It is mandatory to install the backguard.
The range is equipped with 4 LEVELLING FEET and may be levelled by screwing or
unscrewing the feet (fi gs. 1.6 - 1.7).
It is important to observe the directions in fi gures 1.6, 1.8a, 1.8b.
Fig. 1.7
YOU MUST USE STABILITY
ANTI TIP BRACKET TO
PREVENT UNIT FROM
TIPPING.
1. The anti-tip bracket has to be attached as shown on fi gure below (only rear left side),
it has to be fi xed on the fl oor OR on the rear wall by no. 4 (four) suitable screws (not
supplied). Alternatively the anti-tip bracket can also be fi xed on the fl oor AND on the
rear wall by no. 8 (eight) suitable screws (not supplied).
2. After fi xing the anti-tip bracket, slide range into place. Be sure the rear left foot slides
under the anti-tip bracket attached.
10
ANTI-TIP STABILITY
DEVICE FIXING
Anti-tip stability
Dotted line showing the position
of the range when installed
11” 11/16
(297 mm)
device
Rear left
feet of range
Fig. 1.9
11
1
INSTALLING THE COOKTOP FRONT GUARD
To increase the clearance between the front edge of the cooktop and the burners it is possible to install the cooktop front guard supplied
with the appliance.
IMPORTANT: To install/remove the guard it is necessary to remove the cooktop.
Attempting to install/remove the guard without disassembling the cooktop will result in permanent damage to the appliance.
Install the front guard as shown in fi gure 1.10:
1. Remove the backguard.
2. Remove the pan supports, the burner caps and fl ame spreaders.
3. Unscrew cooktop fi xing screws (“A” in fi gure below).
4. Remove the dual burner inner fl ame spreader (“B” in fi gure below).
5. Remove the cooktop (keep attention not to damage the gaskets fi tted above the burner cups - below the cooktop).
6. Install the front guard “C” by inserting the wire terminals into the proper holes above the control panel (“D” in fi gure below).
7. Reassemble the cooktop and the other components (steps from 5 to 1).
Pay special attention to the gaskets fi tted above the burner cups(below the cooktop); if they are damaged they shall be replaced.
A
A
D
A
A
A
A
B
B
D
C
Fig. 1.10
11
12
2
All gas connections must be made according to national and local codes. This gas supply
(service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to the action of LP/Propane gas.
The range is equipped for the use with NA TURAL gas. It is design-certifi ed by CSA Inter-
national for NATURAL and L.P. gases with appropriate conversion.
The model/serial rating plate, located below the bottom drawer, has information on the
type of gas that can be used. If this information does not agree with the type of gas available, check with the local gas supplier. See page from 16 to 19 for L.P. gas conversion
instructions.
gas connection
1. Manual Shut-off Valve (fi g: 2.1):
A manual shut-off valve must be installed in an accessible location in the gas line external
to the appliance for the purpose of turning on or shutting off gas to the appliance (In Massachusetts such shutoff devices should be approved by the Board of State Examiners of
Plumbers & Gas Fitters).
This valve should be located in the same room as the range and should be in a location
that allows ease of opening and closing (in a position where it can be reached quickly in
the event of an emergency).
Do not block access to the shutoff valve. The valve is for turning on or shutting off gas
to the appliance.
Shuto valve
“open” position
To range
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pressure does not exceed 14" water
column.
Examples of a qualified person
include licensed heating personnel, authorized gas company personnel, and authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
Gas supply line
Fig. 2.1
2. Pressure Regulator:
a. All heavy duty, commercial type cooking equipment must have a pressure regulator
on the incoming service line for safe and effi cient operation, since service pressure
may fl uctuate with local demand.
Before installing the regulator mount the 1/2” NPT (conical) male connector to the
regulator (see picture 2.2).
Gasket supplied has to be placed between 1/2” NPT (conical) connector/extension
pipe male pipe fi tting (see picture 2.3).
The regulator supplied with this range must be installed before any gas connections
are made.
Use supplied pressure regulator only.
12
13
PRESSURE REGULATOR INSTALLATION
STEP 1
Mount the 1/2” NPT (conical) male connector to the pressure regulator and
tighten by using a wrench.
Do not over tighten the connector.
Over tightening may crack the regulator.
2
LOCK
Arrow
STEP 2
Assemble the 1/2” NPT connector + pressure regulator group to the extension pipe interposing the gasket supplied.
The regulator cover must be oriented toward the front side of the range.
IMPORTANT: use two wrenches to tighten the connection.
Fig. 2.2
Gasket
Regulator cover
Fig. 2.3
13
14
2
GAS CONNECTION SPECIFICATION
Range
manifold
Manifold male pipe fi tting
1/2” G cylindrical
(ISO 228-1) male
Gasket
Extension
pipe female
pipe fi tting
Extension
pipe male
pipe fi tting
Gasket
1/2” NPT (conical)
male
1/2” G cylindrical
(ISO 228-1) female
Extension
pipe
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
Connector
1/2” NPT
female
To range
To mains
connection
14
Pressure
regulator
Fig. 2.4
1/2” NPT
female
Arrow
WARNING: check the correct positioning of the gas
regulator.
The arrow on the back of the gas regulator must be
oriented toward the connector.
Loading...