80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
3 Amps
47-63 Hz
400 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 8.45%, 50% Load)
0.36 0.62 58.73% 10% 51.61 11.8/0.02 3.36/0.94 5.06/0.94 5.12/0.2 41.01 79.46%
0.50 0.84 38.94% 20% 96.32 11.79/0.05 3.36/1.88 5.05/1.87 5.11/0.39 81.97 85.10%
1.05 0.98 8.45% 50% 235.48 11.82/0.12 3.34/4.7 5.03/4.67 5.08/0.98 205.01 87.06%
2.14 0.98 12.33% 100% 485.40 11.91/0.23 3.31/9.42 4.99/9.32 5.03/1.95 408.60 84.18%
Enermax Technology Corporation
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-2.0
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
2.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current