Emerson Fisher easy-e ED, Fisher easy-e EZ, Fisher YD, Fisher YS Data Sheet

Cast Iron P/T Ratings
D100072X012
Pressure/Temperature Ratings for Fisherr Cast Iron Valve Bodies
Product Bulletin
59.1:015
December 2012
The pressure/temperature ratings for flanged cast iron valves given in the following figure are in accordance with ASME B16.1. Fisher valves with Class B ratings are listed in table 1. Cast iron valves with screwed connections have CL250 ratings in accordance with ASME B16.4.
Information in the following figure has been extracted from Cast Iron Pipe Flanges and Flanged Fittings (ASME B16.1) with the permission of the publisher.
TEMPERATURE, _C
CL250 RATINGS
CLASS B (NPS 1-12)
CLASS A (NPS 1-12)
CLASS B (NPS 14-24)
SATURATED STEAM
The American Society of Mechanical Engineers, United Engineering Center, Three Park Avenue, New York, New York 10016.
Table 1. Class B Ratings
Valve Body
Design
(1)
E
YD, YS 1, 1-1/2, 2, 2-1/2, 3, 4, 6 X X
1. Refers to all valve designs beginning with ā€œEā€ that are available in cast iron, for example: ED, EDR, etc.
Valve Size, NPS CL125B CL250B
1, 1-1/2,2, 2-1/2, 3, 4, 6, 8 X X
CLASS B (NPS 1-12)
CLASS A (NPS 1-12)
CLASS B (NPS 14-24)
A2371-2
www.Fisher.com
CL125 RATINGS
TEMPERATURE, _F
Pressure/Temperature Ratings
Product Bulletin
59.1:015 December 2012
Cast Iron P/T Ratings
D100072X012
Neither Emerson, Emerson Process Management,nor any of their affiliated entitiesassumes responsibility for the selection, use or maintenance of anyproduct. Responsibility for proper selection, use, and maintenance of any product remainssolely with the purchaser and end user.
Fisher isa mark owned by one of thecompanies in the Emerson Process Management business unitof EmersonElectric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they arenot to be construed as warranties or guarantees, express or implied, regarding the products or services described herein ortheir use or applicability. All sales are governed by our terms and conditions, which are available upon request.We reservethe rightto modifyor improvethe designsor specifications of such products at any time without notice.
Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore
www.Fisher.com
E 1989, 2012 Fisher ControlsInternational LLC. All rights reserved.
2