Emerson CF705BC04, CF705ORB04, CF705AW04, CF705PB04, CF705CK04, CF705SCB04, CF705BZH04, CF705HTW04, CF705AGW04, CF705AB04, CF705BS04 User Manual

Size:
198.59 Kb
Download

READ AND SAVE THESE INSTRUCTIONS

 

Model No.

 

CF705AB04

CF705HTW04

 

CF705AGW04

CF705SCB04

 

CF705AW04

CF705ORB04

 

CF705BC04

CF705PB04

 

CF705BS04

CF705WB04

 

CF705BZH04

CF705WW04

52” NORTHWIND®

CF705CK04

 

 

 

Ceiling Fan

 

ENERGY STAR

Net Weight: 16.5 Lbs.

Owner's Manual

 

 

LIMITED WARRANTY

What The Warranty Covers:

This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:

As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:

Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF

REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.

How Can You Get Service:

YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.

To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

To return the product to an authorized service center, call 1-800-654-3545for the address of the nearest authorized service center. You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:

The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:

Repairs by persons not authorized by Emerson Electric Co.,

Use of parts or accessories not authorized by Emerson Electric Co.,

Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or

Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:

The original purchaser or user ceases to own the product, or

The fan is moved from its original point of installation.

This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.

How State Law Relates To The Warranty:

Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Part No. F40BP72240007

Form No. BP7224-7

U.L. Model No.: CF705

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999”and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

2

U.L. Model No.: CF705

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 5/16” blade screwdriver

One wire stripper

Three wire connectors (supplied).

 

MATERIALS

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor(2-wirewith ground) of following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100ft.

12

!WARNING

Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-offboxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

1.Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor assembly

b.One switch housing assembly

c.Five fan blades

d.One ceiling cover

e.Five blade flanges

f.One hanger ball/downrod assembly

g.One hanger bracket

h.One loose parts bag containing:

1.Sixteen M5 x 6 washer head blade screws

2.One M6 x 14 flange screw with lockwasher

3.One wood pendant

4.One coupling

5.Three wire connectors

6.Two threaded studs

7.Two lockwashers

8.Two knurled knobs

9.One clevis pin

10.One hairpin clip

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

2.Remove the fan assembly from the protective plastic bag. Place the fan assembly into the upper foam pad with the top of the motor facing up.

The upper foam pad serves as a holder for the fan during the first stages of assembly.

LOOSE PARTS

BAG

 

 

FAN MOTOR

 

 

ASSEMBLY

 

 

HANGER BALL/

 

 

DOWNROD

 

 

ASSEMBLY

 

BLADE

HANGER

 

FLANGES

 

BRACKET

 

 

CEILING

COUPLING

SWITCH CUP

COVER

ASSEMBLY

COVER

 

FAN

 

 

 

 

BLADES

3

U.L. Model No.: CF705

How to Put Your Ceiling Fan Together

1.Pass the 42” motor leads through the opening in the ceiling cover. Be sure the cover is oriented correctly (Figure 1).

2.Separate, untwist and unkink the three motor leads. Route the motor leads through the hanger ball/downrod assembly.

3.Loosen the two screws in the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 1). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.

MOTOR

M5 x 10 COUPLING

SETSCREWS

CLEVIS PIN

HAIRPIN

CLIP

HANGER BALL/

DOWNROD ASSEMBLY

CEILING

COVER

CLEVIS

CLEVIS

PIN

PIN

M5 x 10

HAIRPIN

SETSCREWS

CLIP

 

 

MOTOR COUPLING

Figure 1

4.While pulling up on the hanger ball, securely tighten the two setscrews in the motor coupling

(Figure 1).

NOTE: The setscrew must be properly installed as described above, or fan wobble could result.

5.The fan comes with blue, black and white leads that are 42-incheslong. Before installing the fan, measure up approximately 6 to9-inchesabove top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation1/2-inchfrom end of leads.

6.Mount the blade flanges to fan blades using three M5 x 6 washer head blade screws per blade (Figure 2).

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

M5 x 6 WASHER HEAD BLADE

SCREW (3)

 

FAN BLADE

Figure 2

BLADE FLANGE

NOTE: Take care not to scratch fan housing when installing blades.

NOTE: Remove and discard the four shipping spacers and screws from the motor hub.

7.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies.

8.Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate. Attach the blade assembly to the motor hub using the two M6 x 14 flange screws preassembled in flange (Figure 3). Make sure all screws are tightened. Repeat this procedure for the other four blade assemblies.

SWITCH HOUSING

BLADE FLANGE

PLATE

 

PREASSEMBLED M6 x 14

MOTOR HUBFLANGE SCREWS (2)

Figure 3

9.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, reengage and reseat the flanges, then tighten the screws again.

10.Engage the connector of the switch housing assembly with the motor connector (Figure 4). The two connectors are keyed and color-codedand must be mated correctly(color-to-color)before they can be engaged. Make sure the connector latch closes properly.

4

U.L. Model No.: CF705

SWITCH

HOUSING

ASSEMBLY

SWITCH HOUSING

CONNECTOR

MOTOR CONNECTOR

Figure 4

11.Remove the three switch housing mounting screws (Figure 4) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three mounting screws (Figure 5).

NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.

SWITCH

HOUSING

ASSEMBLY

Figure 5

MOUNTING SCREWS (3)

12.You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

5

U.L. Model No.: CF705

How to Hang Your Ceiling Fan

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 6).

CEILING

AT LEAST 7'

Figure 6

FLOOR

 

!WARNING

The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

1.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 7.)

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

OUTLET

BOX

TWO SCREWS

 

SUPPLIED WITH

HANGER

OUTLET BOX

 

BRACKET

Figure 7

TAB

Figure 2

 

2.Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 8). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 7).

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

NOTE: CEILING COVER,

 

SUPPLY WIRES AND

OUTLET

FAN WIRES OMITTED

BOX

FOR CLARITY.

 

HANGER

BRACKET

Figure 8

HANGER BALL/

Figure 3

DOWNROD ASSEMBLY

 

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

6

U.L. Model No.: CF705

How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

!WARNING

To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.

1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied. (Figure 9.)

NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 9). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 9). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.

 

BLACK AND BLUE

NOTE: CEILING COVER

GROUND

FAN WIRES

OMITTED FOR CLARITY.

 

 

WIRE

 

 

LISTED

 

WHITE SUPPLY

WIRE

 

CONNECTOR (3)

 

(NEUTRAL)

GREEN WIRE

 

 

(GROUND) FROM

 

WHITE FAN

HANGER BRACKET

 

WIRE

Figure 9

GREEN WIRE

BLACK SUPPLY

(GROUND) FROM

(HOT)

 

HANGER BALL

 

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

3.Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.

4.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 10).

5.Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 10.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.

 

CEILING COVER

THREADED STUD

LOCKWASHER

 

KNURLED KNOB

Figure 10

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

6.Cut the 3-speedswitch pull chain to a desired length (optional). Connect the wood pendant (supplied) to the3-speedswitch pull chain by sliding the wooden pendant (small hole first) onto the pull chain. Attach the chain coupler to the end of the chain and allow the wooden pendant to fall down over the coupling.

7

U.L. Model No.: CF705

Using Your Ceiling Fan

1.Restore electrical power to the outlet box by turning the electricity on at the main fuse box.

2.Check the operation of the fan by gently pulling on the pull chain switch.

All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direction, turn your fan OFF and wait for the blades to stop turning, then slide the reversing switch to the “up” position, and turn fan on again.

4.The fan blades will turn in the opposite direction and reverse the airflow.

Your fan model is equipped with a 4-position,3-speedpull chain switch. The operating sequence is as follows:

Three-Speed

1st Pull—HIGH

2nd Pull—Medium

3rd Pull—Low

REVERSIBLE

SPEED

SWITCH

CONTROL

SWITCH

4th Pull—OFF

Reverse Switch Information

Season

Rotation Direction

Switch Position

Summer

Counter-Clockwise

Down

 

 

 

Winter

Clockwise

Up

Energy Efficient Use of

Ceiling Fans

Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan. Here are a few tips to ensure quality and product performance.

Choosing the Appropriate Mounting Location.

Ceiling fans should be installed, or mounted, in the middle of the room and at least 7 feet above the floor and 18 inches from the walls. If ceiling height allows, install the fan 8 - 9 feet above the floor for optimal airflow. Consult your Emerson Retailer for optional mounting accessories.

Using the Ceiling Fan Year Round. In the summer, use the ceiling fan in the counter-clockwise direction. The airflow produced by the ceiling fan creates a wind-chill effect, making you "feel" cooler. Select a fan speed that provides a comfortable breeze, lower speeds consume less energy. In the winter, reverse the motor and operate the ceiling fan at low speed in the clockwise direction. This produces a gentle updraft, which forces warm air near the ceiling down into the occupied space. Remember to adjust your thermostat when using your ceiling fan - additional energy and dollar savings could be realized with this simple step!

Turn Off When Not in the Room. Ceiling fans cool people, not rooms. If the room is unoccupied, turn off the ceiling fan to save energy.

8

U.L. Model No.: CF705

Maintenance

Accessories

IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.

Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

!WARNING

Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

1.Ceiling Fan Light Kits (see store or catalog).

2.Ceiling Fan/Light Controls (see store or catalog).

3.Downrod Extension Kits (see store or catalog).

!WARNING

The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

!WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble Shooting

 

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

 

1.

Fan will not start.

1. Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit breakers.

 

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch switch wire

 

 

 

switch wire connections in the switch housing.

 

connections in the switch housing.wire connections in the switch

 

 

 

 

 

housing.

 

 

 

 

!

WARNING: Make sure main power is turned off.

 

 

3.

Reversing switch in neutral position.

3.

Make sure reversing switch position is all the way to one side.

 

 

 

 

 

2.

Fan sounds noisy.

1. Blades not attached to fan.

1.

Attach blades to fan before operating.

 

 

2.

Screws securing fan blade flanges to motor

2.

Check to make sure the screws which attach the fan flanges to the

 

 

 

are loose.

 

motor are tight.

 

 

3.

Wire connectors inside switch housing rattling.

3.

Check to make sure wire connectors in switch housing are not

 

 

 

 

 

rattling against each other or against the interior wall of the switch

 

 

 

 

 

housing.

 

 

 

 

!

WARNING: Make sure main power is turned off.

 

 

4.

Motor noise caused by solid-statevariable

4.

Some fan motors are sensitive to signals from Solid-Statevariable

 

 

 

speed control.

 

speed controls. If Solid-StateControl is used and motor noise

 

 

 

 

 

results choose an alternative control method.

 

 

5.

Screws holding blades to flanges are loose.

5.

Tighten screws securely.

 

 

 

 

3. Fan wobbles

1. Setscrew and jam nut in motor coupling are not

1.

Raise coupling cover and tighten setscrew and jam nut securely.

 

excessively.

 

tightened securely.

 

 

 

 

2.

Setscrew in the hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/downrod assembly.

 

 

 

loose.

 

 

 

 

3.

Screws securing fan blade flanges to motor are loose.

3.

Check to be sure screws which attach the fan blade flanges to the

 

 

 

 

 

motor are tight.

 

 

4.

Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat firmly and uniformly to

 

 

 

 

 

the surface of the motor. If flanges are seated incorrectly, loosen

 

 

 

 

 

the flange screws and retighten according to the procedure in the

 

 

 

 

 

section on "How to Put Your Ceiling Fan Together".

 

 

5.

Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet box, and/or secure

 

 

 

securely fastened

 

outlet box.

 

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side)blade pair can redistribute

 

 

 

 

 

the weight and result in smoother operation.

 

 

 

 

 

 

9

U.L. Model No.: CF705

Repair Parts

 

 

2

 

1

 

3

 

 

 

 

5

 

10

9

4

 

6

 

 

 

 

 

7

 

 

 

8

17

 

 

 

 

18

16

 

11

13

15

12

14

 

Before discarding packaging material, be certain all parts have been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

PART NUMBER

NAME OF ITEM

PART DESCRIPTION

MODEL NUMBER

The model number of your Fan will be found on a label attached to the top housing.

For repair parts, phone 1-800-654-3545.

10

U.L. Model No.: CF705