Planned Maintenance Programmes
Core Probe
3
4
1
3
6
Clean by hand, using lukewarm water and neutral soap, then rinse with clean water and a sanitizing solution.
4
Facade, Door and
Door Gasket
Remove by hand any dirt, drips or splashing with a paper-towel; clean by hand, using lukewarm water and neutral soap, then rinse with clean water.
daily
daily
In order to ensure the safety and performance of your equipment, it is recommended that regular service is undertaken every 12 months by Electrolux Professional authorised engineers in accordance with the manufacturer recommendations. Please contact your local Electrolux Professional Service Centre for further details of service agreements available.
Suggested for you
For more Accessories & Consumables
please look at our Catalogues or contact our Electrolux Professional Service Partner.
1
Cavity cleaning
Run an Hygiene cycles at the end of the day.
Drain Plug
2
Clean with lukewarm water and neutral soap, then rinse and dry thoroughly.
2
7
5
daily
daily
5
Trolley
If used in combination with Electrolux Professional Ovens, clean with the Oven Cycle; as alternative, use lukewarm water and neutral soap, then rinse and dry thoroughly.
6
Tray supports and
internal structure
Remove the supports and the structure and wash in a dish-washer; as alternative, clean by hand with lukewarm water and neutral soap, then rinse with clean water and a sanitizing solution.
7
Air Inlet Grid
Remove the dust with a vacuum cleaner.
daily
per
week
1
per
month
1
Cleaning external surfaces
strongly recommends to use Electrolux Professional approved cleaning agents, rinse and descaling agents to obtain better results and maintain product efficiency over time. Damages caused by cleaning, as a consequence of use of not approved cleaning agents,
rinse and descaling, will be excluded by the warranty.
The operations described must be performed wearing the needed Personal Protection Equipment. Refer to the User Manual.
05UME34____ENG00
2020-04-15
Runners for 6-10 GN 1/1
blast chiller freezer.
093862
(Left runner for BCF 30-50kg)
093861
(Right runner for BCF 30-50kg)
Non-stick U-pans with coating
925000 (20mm deep) 925001 (40mm deep) 925002 (60mm deep)
Trolley Track rack 16 GN 2/1
80 mm pitch
922046
Bakery/pastry Trolley for 20 GN
2/1 oven - 16 racks 400x600mm 80 mm pitch
922069
Runners for 10 GN 2/1
blast chiller freezer.
093994
(Left runner for BCF 70kg)
093995 (Right runner
for BCF 70kg)
Trolley Track rack 20 GN 2/1
63 mm pitch
922044
Banqueting Trolley 92 plates
for 20 GN 2/1 oven 85 mm pitch
922055
Probe holder for liquids
922714
Essentia
Anomaly Description Instructions to User
swcTTm
ECoM
PFAC
PdEF
Food probe not inserted in food
Communication error between boards
Memorized parameters corrupted
Memorized default parameters corrupted
In case of cycles based on food temperature, insert the probe into the food otherwise the cycle will automatically switch to time
- Try to switch the unit OFF/ON
- If the problem persists, Call Service
- Try to switch the unit OFF/ON
- If the problem persists, Call Service
- The machine loses personalization. Operations can continue
- If the problem shows up again, Call Service
- Call Service
- 6GN 1/1 models (1 evaporator fan): unit stops and cannot operate until fixing the problem
EFnt
Top evaporator fan failure
- Other models (more than 1 evapo- rator fan): unit continues working with reduced performance (Cycle ongoing: the cycle proceeds until end if there is at least one fan working. The cycle stops if no fan is working)
- During STANDBY: the alarm cannot be triggered
- Unit continues working with reduced performance until at least another fan is working (Cycle ongoing: the cycle proceeds until end if there is at least one fan working. The cycle stops if no fan is working)
- During STANDBY: the alarm cannot be triggered
EFnb
Bottom evaporator fan failure
- Call Service
- Unit continues working with reduced performance until at least another fan is working (Cycle ongoing: the cycle proceeds until end if there is at least one fan working. The cycle stops if no fan is working)
- During STANDBY: the alarm cannot be triggered
EFnc
Center evaporator fan failure
- Call Service
Anomaly Description Instructions to User
- Cycle on going: the cycle restart automatically when the power is back
B4 Supply power missing
- The machine was not in operation for a certain time: check initial and end time
- Check the plug or general electric control pane
- If the alarm reoccurs, Call Service
Ertc Low battery Problem with battery of internal clock. Call Service
- The cavity temperature has exceeded the set limit, in additional to the signal delay time
- Cycle on going: the cycle goes on
- If the alarm persists even if the cavity temperature is low, call service.
ECHt
Cavity high temperature
- The chiller will be blocked and only fan condenser run
E11 Compressor failure
- Check if there is some obstruction of suction air condenser
- Call Service
- Ensure the chiller door is closed and any physical obstruction is not preventing
B2 Door open
the door closure
- Start new cycle: if either a new cycle will not start or the alarm persists even with the door closed, Call Service
E1 Cavity probe failure
E4
E14
E15
E16
Eprb1 / Eprb6
Evaporator probe failure
Out Evaporator probe failure
Condenser probe failure
Condenser high temperature
Core probe failure sensor n° 1/6
- Call Service
- The chiller will continue working until the end of the running cycle
- Not possible start other cycle till to Technical Service replace the probe
- The chiller will continue working: the defrost setting will be based on time
- Call Service and inform about the message displayed
- The chiller will continue working
- Call service and inform about the message displayed
- Call Service
- This failure blocks also running cycle
- Quickly remove the load from the cavity for preventing waste of food
- This failure blocks also running cycle
- Quickly remove the load from the cavity for preventing waste of food
- Using a vacuum cleaner, remove any dust/dirt from the condenser inlet-air grid
- If the alarm persists, Call Service
- Cycle on going: the cycle goes on in probe mode if there is at least one of the food probe working
- The cycle switches to time mode if none food probe is working
- During STANDBY: the cycle can be started
- Cycle start: only by time
- Call Service