Efd Ultra 2800 Settings Grid

A NORDSON COMPANY
Ultra®2800 Dispensing System Settings Grid
This guide presents an initial starting point to help you set your specifications on the Ultra 2800 Dispensing System. Settings will vary according to the assembly fluid you are using and the type of deposit you are making. A few reminders:
• Use a tapered tip, especially when dispensing thick fluids. Tapered tips require less pressure and help prevent oozing.
• Use the slowest speed practical to your dispensing application.
• For best results, make small changes to one setting at a time. Dispense again to observe results; adjust as needed.
Suggested Settings/Ultra 2800-30 (30cc syringe barrels)
Sample Forward Dispense Pause Pullback
Deposit Size
Fluid Type and Viscosity EFD Tip (gauge/color)
Steps Rate (cc/s) (ms) Steps
Medium
n/a
Alcohol
Green 18 gauge general purpose tip 37 steps (0.010240 0 150 steps
0.0118cc deposit cc/sec)
Medium
n/a
Alcohol
Green 18 gauge general purpose tip 16 steps (0.010240 0 250 steps
0.0051cc deposit cc/sec)
Medium
n/a
Alcohol
Red 25 gauge general purpose tip 2 steps (0.010240 0 200 steps
0.0006cc deposit cc/sec)
Medium
EFD red test material
Olive 14 gauge tapered tip 30 steps (0.010240 0 620 steps
0.0096cc deposit cc/sec)
Medium
EFD red test material
Pink 20 gauge tapered tip 3 steps (0.010240 0 630 steps
0.0009cc deposit cc/sec)
Suggested Settings/Ultra 2800-10 (10cc syringe barrels)
Sample Forward Dispense Pause Pullback
Deposit Size
Fluid Type and Viscosity EFD Tip (gauge/color)
Steps Rate (cc/s) (ms) Steps
Medium
EFD red test material
Olive 14 gauge tapered tip 93 steps (0.004955 0 385 steps
0.0144cc deposit cc/sec)
Medium
EFD red test material
Pink 20 gauge tapered tip 20 steps (0.004955 0 400 steps
0.0030cc deposit cc/sec)
Medium
EFD red test material
Pink 20 gauge tapered tip 2 steps (0.004955 0 200 steps
0.0003cc deposit cc/sec)
Recommended Customer Settings
Forward Dispense Pause Pullback
Fluid Type and Viscosity EFD Tip (gauge/color)
Steps Rate (cc/s) (ms) Steps
Unit: Ultra 2800-3 Ultra 2800-5 Ultra 2800-10 Ultra 2800-30
Suggested Settings/Ultra 2800-5 (5cc syringe barrels)
Sample Forward Dispense Pause Pullback
Deposit Size
Fluid Type and Viscosity EFD Tip (gauge/color)
Steps Rate (cc/s) (ms) Steps
Medium
EFD red test material
Olive 14 gauge tapered tip 100 steps (0.003211 0 400 steps
0.0100cc deposit cc/sec)
Medium
EFD red test material
Pink 20 gauge tapered tip 46 steps (0.003211 0 450 steps
0.0046cc deposit cc/sec)
Medium
EFD red test material
Red 25 gauge tapered tip 3 steps (0.003211 0 300 steps
0.0003cc deposit cc/sec)
Suggested Settings/Ultra 2800-3 (3cc syringe barrels)
Sample Forward Dispense Pause Pullback
Deposit Size
Fluid Type and Viscosity EFD Tip (gauge/color)
Steps Rate (cc/s) (ms) Steps
Medium
EFD red test material
Olive 14 gauge tapered tip 77 steps (0.001829 0 148 steps
0.0044cc deposit cc/sec)
Medium
EFD red test material
Green 18 gauge general purpose tip 30 steps (0.001829 0 220 steps
0.0017cc deposit cc/sec)
Medium
EFD red test material
Red 25 gauge tapered tip 6 steps (0.001829 0 340 steps
0.0003cc deposit cc/sec)
USA: 800-556-3484 or +1-401-434-1680 Europe: 0800 585733 or +44 (0) 1582 666334 Asia: +86 (21) 5854 2345 technical@efd-inc.com www.efd-inc.com
©2006 Nordson Corporation 2800-GRID-01 v062606