• When the piston is secured on the plunger make sure
you are still in Manual mode (hand button lit). Start to
retract the syringe barrel back to the adapter by
pressing and holding the Pullback button.
Note: Go slowly — if you retract the barrel too far,
the plunger will disengage from the piston, and you
will need to start over at Step 1.
• Continue retracting the barrel until only a small gap
remains between the barrel and the adapter.
• When the barrel has been retracted, slide the barrel
retainer over the syringe barrel and thread the
retainer one full turn only onto the adapter.
• Replace the tip cap with the appropriate dispense tip.
Fully tighten the barrel retainer onto the adapter.
• As you tighten the barrel onto the adapter, fluid
should start to flow into the dispense tip. Depending
on the gap left between the barrel and adapter in
Step 3, fluid may partially fill the tip or start to purge
out of the tip.
• If the fluid only partially filled the tip, make sure the
dispenser is in Manual mode (hand button lit) and
press and hold the foot pedal to finish purging the tip.
• Once the tip is completely purged you are ready to
dispense.
Adapter
Barrel
Retainer
Leave a
small gap
Retract Plunger
3
Attach Barrel to Adapter
4
Attach Dispense Tip
5
Purge Tip & Dispense
6
For EFD sales and service in over 30 countries,
contact EFD or go to www.efd-inc.com/contact
EFD, Inc.
East Providence, RI USA
800-556-3484; +1-401-434-1680 (outside the USA)
info@efd-inc.com www.efd-inc.com
EFD International Inc.
Dunstable, Bedfordshire, UK
0800 585733 or +44 (0) 1582 666334
Ireland 00800 8272 9444
europe@efd-inc.com www.efd-inc.com
EFD, Inc., Asia
China: +86 (21) 5854 2345
china@efd-inc.com www.efd-inc.com/cn
Singapore: +65 6896 9630 sin-mal@efd-inc.com
©2006 Nordson Corporation LIT-2800-PISTON-01 v062606