Efd Ultra 2400 Quick Start Guide

• Remove barrel holder sleeve from holder.
• Loosen the 6 mm screw from T-nut.
• Slide T-nut into left or right panel of workstation slot, positioning as shown.
• Tighten 6 mm screw, securing holder to workstation panel.
• Insert barrel holder sleeve.
• Loosen screw from wire hose holder T-nut.
• Tighten screw to secure wire hose holder to workstation.
Easy 14-Step Setup
Follow these steps to get your Ultra 2400 ready for operation.
®
A NORDSON COMPANY
Ultra®2400 Series Dispensing Workstation
• Connect the power plug to the power pack. The unit is shipped with a USA-compatible plug and three international plugs. Attach the correct plug to match local power outlets.
• Connect the power cord into the back of the Ultra 2400.
• Connect the power cord into your local power source.
• Press the power switch on the front panel.
Power cord
Quick Start Guide
• Unpack the unit.
• Now is a good time to activate your extended Ten Year No-Fault Warranty. Register the warranty online at www.efd-inc.com/warranty/ten.
Unpack the Unit/Warranty
1
Install Barrel Holder
2
Connect Power
3
1
Electronic pdf files of EFD manuals are also available at www.efd-inc.com/manuals.html
3
1
8
4
2
7
6
5
Note: Clean, dry, filtered factory air is required to meet warranty. If your air supply is not filtered, order the five-micron filter regulator (#2000F755).
• Push one end of the air input hose into the input fitting on the back of the Ultra 2400.
• Connect the other end of the air input hose to your plant air supply.
For all Ultra 2400 Series units (models 2400, 2415, and 2405): Set plant air supply within 80 to 100 psi (5.5 bar to 6.9 bar).
• Secure an EFD syringe barrel filled with your fluid to the adapter assembly.
• Replace tip cap with an EFD precision dispense tip.
See the User’s Guide for syringe barrel filling techniques.
When powered for the first time, the Ultra 2400 Home screen displays in TIMED mode. Otherwise, it displays in the mode last used.
• You can verify what mode you are in by checking the top left corner of the display screen. It will be TIMED, TEACH, STEADY or MEMORY.
• If needed, return to the Home screen from TEACH or STEADY mode by pressing TIMED in the bottom right corner of the display.
• Return to the Home screen from MEMORY mode by pressing MENU, then selecting TIMED.
• Push in the EFD adapter assembly provided into the back of the Ultra 2400 and twist to lock.
The Ultra 2400 features two air output connections. You can connect the adapter assembly to the back panel or to the front panel, whichever is most convenient.
TIP
Input air
TIP
Back panel output air
The Ultra 2400 is normally operated using the foot pedal provided.
• Plug the foot pedal into the back of the Ultra 2400.
You can also operate the Ultra 2400 with an optional finger switch or a 5 to 24 VDC pulse. See the User’s Guide for details.
TIP
Foot pedal
Timed Mode
Front panel
output air
2
Connect Foot Pedal
4
Connect Air Input
5
Connect Air Output
6
Attach Syringe Barrel & Tip
7
Select Timed Mode
8
Menu
See the Ultra 2400 Icon Guide, included with your dispensing system, if you are working in Chinese, Japanese, or Korean. Sample icons:
(Timed) (Steady) (Teach) (Menu) (Select) (Home)
NOTE: Arrow on cord connector faces up
Arrow on top
The Ultra 2400 is shipped with default settings for the display of language (in English); air pressure (psi); and vacuum (inH
2
O). Skip to step #10 if these
display settings are acceptable.
Otherwise, follow these steps to change the display settings:
• From the Home screen, press MENU.
• Press the down arrow to highlight Units of Pressure, Units of Vacuum, or Language.
• Press SELECT.
• Press the down arrow to highlight your choice.
• Press SELECT again to make the change and return to the Home screen.
• From the Home screen, press MENU.
• Press the down arrow to select SET CLOCK.
• Press SELECT.
• Use the left/right arrow to highlight the number to change.
• Press the up/down arrow or use the timer (top right knob) to adjust each number. Then use the up/down arrow or timer dial to toggle between AM (morning) and PM (afternoon/evening).
• Press SAVE. This saves the time and returns you to the Home screen.
The Ultra 2400 is shipped with all values set to zero. To set dispense time, follow these steps:
• Begin in TIMED mode.
• Press the left/right arrows to select a single number in the time row.
• Press the up/down arrows to set the time.
Once a single digit in the time row is selected, you can also use the timer dial (top right knob) to adjust the dispense time.
Set air pressure by turning the air pressure regulator (bottom left knob).
• Pull the air pressure regulator knob out to unlock it.
• Turn the regulator knob clockwise to reach the correct air pressure setting.
• Push the air pressure regulator knob in to lock the setting.
TIP
Timer knob
Air pressure knob
9
Select Display Settings
10
Set Clock
11
Set Dispense Time
12
Set Air Pressure
3
Helpful Hints
• There are three core variables to the Ultra 2400: time, pressure and vacuum. Adjust just one of these at a time, in small increments, to achieve your ideal deposit.
• Another important variable is tip size. Choose the right tip for your deposit type. Remember, smaller tips require more pressure and time. Try different tips without changing the time or pressure settings to observe the results.
• Tapered tips reduce the amount of pressure needed to dispense thick materials. They also help prevent drooling at the end of the dispense cycle.
• Use EFD SmoothFlow
pistons to prevent oozing. Pistons also make barrel loading,
dispensing and fluid handling cleaner, safer and more accurate.
• Avoid high pressure (example: 80 psi; 5.5 bar) with very short time settings (less than
000.0100). The ideal setup matches air pressure and tip size to produce a “workable” flow rate — no splashing but with a time setting that is not extremely low.
• Longer dispense time settings generally provide the highest accuracy.
During initial testing and setup we recommend that you keep the vacuum setting at 0.0 inH2O. After initial testing, set vacuum by turning the vacuum regulator (bottom right knob).
• Pull the vacuum regulator knob out to unlock it.
• Turn the regulator knob clockwise to reach the correct vacuum setting.
• Push the vacuum regulator knob in to lock the setting.
• Purge the dispense tip. From STEADY mode, press the foot pedal until material flows from the tip.
• Return to TIMED mode.
• Press the foot pedal once to begin your next dispense cycle.
Hold the tip at a 45º angle to the work surface.
Vacuum knob
TIP
4
13
Set Vacuum
14
Dispense
©2006 Nordson Corporation 2400-GUIDE-01 v062606
This equipment is regulated by the European Union under WEEE Directive (2002/96/EC). See www.efd-inc.com for information about how to properly dispose of this equipment.
For EFD sales and service in over 30 countries, contact EFD or go to www.efd-inc.com/contact
EFD, Inc.
East Providence, RI USA 800-556-3484; +1-401-434-1680 (outside the USA) info@efd-inc.com www.efd-inc.com
EFD International Inc.
Dunstable, Bedfordshire, UK 0800 585733 or +44 (0) 1582 666334 Ireland 00800 8272 9444 europe@efd-inc.com www.efd-inc.com
EFD, Inc., Asia
China: +86 (21) 5854 2345 china@efd-inc.com www.efd-inc.com/cn Singapore: +65 6896 9630 sin-mal@efd-inc.com
A NORDSON COMPANY
45º
Loading...