Efd 725D INSTALLATION GUIDE

Page 1
Introduction
The 725D Series is simple to use and will operate many millions of cycles without maintenance.
The unique design of the 725D Series valve provides a clean fluid cutoff with pullback for precise fluid application at high cycle rates.
The 725DA-SS and 725DA valves feature an adjustable pullback and flow control. The 725D and 725D-SS do not have the adjustable feature.
Each valve is shipped with a dispensing tip adapter, fluid inlet fitting and 5-feet actuating air hose installed. For high flow applications, the dispensing tip adapter can be removed for installation of 1/4 NPT metal or plastic nozzles.
725D Series Piston Valve
INSTALLATION GUIDE
Electronic pdf files of EFD®manuals are also available at www.efd-inc.com/manuals.html.
USA: 800-556-3484 or +1-401-434-1680 Europe: 0800 585733 or +44 (0) 1582 666334 Asia: +86 (21) 5854 2345 technical@efd-inc.com www.efd-inc.com
®
A NORDSON COMPANY
supply line
Inlet fitting
1/8 NPT
Control air hose
Fluid
Air cylinder body
Open
Close
Stroke adjustment
Fluid body
Tip adapter 1/4 NPT
Dispensing tip
Page 2
Installation
1
7
5
C
l
o
s
e
O
p
e
n
3
Set desired deposit size by adjusting valve open time. Refer to valve controller operating manual.
10
1. Mount valve with an EFD universal
valve mount (#7002VM) or other fixture.
2. Connect fluid supply line to valve. If
3/8” tubing is used, change to fitting #7610BP supplied.
3. Connect fluid supply line to reservoir.
The reservoir can accept either 1/4” OD or 3/8” OD tubing using #62518PT supplied.
4. Connect valve control air hose to
ValveMate
TM
controller (or other pneu­matic switch) used to control valve open time.
5. Choose a dispensing tip or nozzle—
small tips (18-20 gauge) for low viscosity fluid and larger tip or nozzle for higher viscosities.
6. Fill reservoir by pouring fluid directly
into tank liner or manufacturer’s bottle placed inside reservoir. Secure cover prior to setting pressure.
7. Set reservoir pressure to low for thin
fluids and higher for thick fluids.
8. Place a cup under the dispensing tip
or nozzle and actuate the valve until fluid lines, valve and dispensing tip are free of air.
9. Set desired flow rate by adjusting fluid
reservoir pressure, valve stroke setting
*
or changing dispensing tip or nozzle.
10. Set desired deposit size by adjusting
valve open time. Refer to valve controller operating manual.
*
725DA and 725DA-SS only
8
Air Output
Exhaust
2
6
4
9
Prior to installing this valve, please read the associated reservoir and valve controller operating instructions to become familiar with the operation of all components of the dispensing system.
To exhaust
To pressurize
A NORDSON COMPANY
®
Steady
Test
Run
Setup Program
Time Set
Clear
Fast Slow
POWER
RUN
SETUP
CYCLE
Fast Slow
Time Set
Pressure
STOP
Time
Purge
Page 3
closed
open
How the Valve Operates
Input air pressure at 70 psi*(4.8 bar) forces the internal piston
to move down, causing the diaphragm seal ➁to deflect and the sealing head ➂to open and permit fluid flow. When the input air pressure exhausts, the spring retracts the piston and the sealing head closes, stopping the fluid flow and pulling back a slight amount of fluid.
The primary control of deposit size is the valve open time.
ValveMate Concept
The ValveMate 7000 provides easy adjustment of valve output for maximum end user convenience and efficiency. Valve open time is the primary control of deposit size. The 7000 puts push-button adjustment of valve open time where it needs to be—at the valve.
Deposit size can be programmed by pressing the PROGRAM button in the SETUP mode. This affords an easy starting point for selecting deposit size.
Note: The EFD Ultra®TT 325 and 525 XYZ automated dispensing systems have integrated ValveMate controllers for operating all EFD dispense valves.
The amount of fluid dispensed will depend on the time the valve is open, the viscosity of the fluid, the air pressure in the fluid reservoir and the dispensing tip size.
Flow rate is a function of reservoir pressure, stroke adjustment setting, tip size and fluid viscosity.
*
For stripes and lines, input air pressure can be lowered to eliminate opening surge.
www.efd-inc.com technical@efd-inc.com USA 800-556-3484 Europe +44 (0) 1582 666334 Asia +86 (21) 5854 2345
Purge
Time Set
Clear
Fast Slow
Fast Slow
Time Set
POWER
RUN
SETUP
CYCLE
Pressure
STOP
Time
Control Pad set time timer bypass display pressure (psi, bar) TEACH program test cycle purge reset
Function Indicators
Pressure/Time Toggle
Emergency Stop
Steady
Test
A NORDSON COMPANY
VALVEMATE 7000
®
Run
Setup Program
Rear Panel air input power input (voltage selector) air output to valve I/O connector with alarm output (<60 psi) connector for optional foot pedal
Page 4
Specifications
725DA-SS and 725DA
Size: 149.1 mm length x 29.5 mm diameter
(5.87” x 1.16”)
Weight:
725DA-SS: 321 grams (11.32 oz) 725DA: 241 grams (8.5 oz)
Fluid body and cap:
725DA-SS: Type 303 stainless steel 725DA: Hard-coated aluminum
725D-SS and 725D
Size: 123.4 mm length x 28.5 mm diameter
(4.86” x 1.12”)
Weight:
725D-SS: 279 grams (9.85 oz) 725D: 196 grams (6.91 oz)
Fluid body and cap:
725D-SS: Type 303 stainless steel 725D: Hard-coated aluminum
General
Valve seal/diaphragm: FDA-approved UHMW* polymer
Fluid inlet thread: 1/8 NPT female
Output thread: 1/4 NPT female
Mounting hole: (1) 1/8 NPT female blind hole
Air pressure required: 70 to 90 psi (4.8 to 6.2 bar)
Maximum fluid pressure: 100 psi (6.9 bar)
Maximum operating temperature: 43°C (110°F)
* Ultra High M
olecular Weight
For consistent dispense valve operation and easy adjustment of valve output, EFD recommends using the ValveMate 7000 con­troller on all automatic, semi-automatic and benchtop applica­tions.
The EFD Ultra TT Series positioning systems incorporate dispens­ing control into the main system.
Contact the EFD Dispense Valve Systems Group for details.
For EFD sales and service in over 30 countries, contact EFD or go to www.efd-inc.com/contact
EFD, Inc.
East Providence, RI USA 800-556-3484; +1-401-434-1680 (outside the USA) info@efd-inc.com www.efd-inc.com
EFD International Inc.
Dunstable, Bedfordshire, UK 0800 585733 or +44 (0) 1582 666334 Ireland 00800 8272 9444 europe@efd-inc.com www.efd-inc.com
EFD, Inc., Asia
China: +86 (21) 5854 2345 china@efd-inc.com www.efd-inc.com/cn Singapore: +65 6896 9630 sin-mal@efd-inc.com
©2006 Nordson Corporation 725D-INSTALL-01 v062606
®
A NORDSON COMPANY
Loading...